Optimal Dosage of Indocyanine Green Fluorescence for Intraoperative Positive Staining in Laparoscopic Anatomical Liver Resection

被引:5
|
作者
Kasai, Meidai [1 ]
Aihara, Tsukasa [1 ]
Ikuta, Shinichi [1 ]
Nakajima, Takayoshi [2 ]
Yamanaka, Naoki [1 ]
机构
[1] Meiwa Hosp, Dept Surg, Nishinomiya, Hyogo, Japan
[2] Meiwa Hosp, Dept Surg, Nishinomiya, Japan
关键词
roc curve analysis; positive staining; indocyanine green; fluorescence imaging technology; laparoscopic anatomical liver resection; NAVIGATION;
D O I
10.7759/cureus.46771
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionFluorescence imaging technology, specifically utilizing indocyanine green (ICG), has emerged as a valuable tool in laparoscopic hepatectomy. In particular, laparoscopic anatomical liver resection (ALR) has benefited from the implementation of both positive and negative staining methods. A case series study reported a success rate of 53% for the positive staining method, citing potential issues regarding the proper ICG dosage needed for accurate fluorescence. Thus, it is crucial to conduct research to investigate the optimal dosage for ICG-positive staining in clinical practice to maximize the benefits of this technique.Materials and methodsThis retrospective study was conducted at a single center, Meiwa Hospital, and received approval from the hospital's ethics committee in accordance with the Helsinki Declaration. We reviewed the records of 264 patients who underwent open and laparoscopic hepatectomies for benign and malignant liver diseases from January 2019 to January 2023. Of these, 18 patients who underwent laparoscopic ALR with the ICG-positive staining method were evaluated. Fluorescence-emitting segmental borders were assessed immediately after puncture (first stage) and during parenchymal dissection (second stage). In the first stage, we evaluated the intensity of fluorescence emission, categorizing it as "strong" or "weak." The absence of visible fluorescence emission was considered a puncture failure. During the second stage of evaluation, from parenchymal resection to completion, we assessed the sustainability of fluorescence emission, defining it as "clear" or "contaminated." Both evaluations were subjectively judged by three surgeons at our center. The ICG quantity per targeted portal vein-bearing liver volume (mg/100 mL) was calculated for each patient, and the optimal dosage was determined using receiver operating characteristic (ROC) curve analysis. To ascertain the minimum value for adequate fluorescence emission intensity, ROC curve analysis was performed to discriminate between binary outcomes of "strong" or "weak" emission. Furthermore, to establish the maximum value for maintaining a clear fluorescence border, ROC curve analysis was conducted to discriminate between "clear" and "contaminated" during the second evaluation.ResultsAmong the 18 successful puncture cases, the first-stage evaluation of fluorescence intensity revealed 14 punctures with "strong" intensity and four punctures with "weak" intensity. In the second-stage evaluation, 13 cases demonstrated "clear" borders, while five cases exhibited "contaminated" borders. ROC curve analysis was performed to determine the optimal ICG dose for adequate fluorescence intensity and preservation of clear borders during dissection. The analysis indicated that the appropriate ICG dose for achieving optimal intensity was 0.028 mg/100 mL (area under the curve [AUC]: 0.893), while the dose that prevented contamination of fluorescence in non-target areas until after dissection was 0.083 mg/100 mL (AUC: 0.723).ConclusionsLaparoscopic anatomical resection using the positive staining method requires an optimal ICG dosage of 0.028-0.083 mg per 100 mL of liver volume. By employing this methodology, more precise and safer laparoscopic anatomical resections can be conducted, thereby enhancing the safety of the surgical procedure for patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Pure Laparoscopic Anatomic Resection of Liver Segment 4 with Middle Hepatic Vein Involvement Using Indocyanine Green Fluorescence Staining
    Yani Liu
    Yufu Peng
    Yonggang Wei
    Annals of Surgical Oncology, 2024, 31 : 1271 - 1271
  • [22] Application of Indocyanine Green Fluorescence as an Adjuvant to Laparoscopic Ultrasound in Minimally Invasive Liver Resection
    Piccolo, Gaetano
    Barabino, Matteo
    Diana, Michele
    Lo Menzo, Emanuele
    Epifani, Angelo Gabriele
    Lecchi, Francesca
    Santambrogio, Roberto
    Opocher, Enrico
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2021, 31 (05): : 517 - 523
  • [23] A pilot study of virtual liver segment projection technology in subsegment-oriented laparoscopic anatomical liver resection when indocyanine green staining fails (with video)
    Zeng, Xiaojun
    Deng, Haowen
    Dong, Yanchen
    Hu, Haoyu
    Fang, Chihua
    Xiang, Nan
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2024, 38 (07): : 4057 - 4066
  • [24] Indocyanine Green Fluorescence Guidance and Initial Pedicle Portal Approach for Laparoscopic Segmentary Liver Resection
    Herrero-Fonollosa, Eric
    Tur-Martinez, Jaume
    Arias-Aviles, Melissa
    Cugat Andorra, Esteban
    CIRUGIA ESPANOLA, 2021, 99 (01): : 62 - 62
  • [25] Concomitant Use of Indocyanine Green Fluorescence Imaging and Interventional Radiology for Detection of Liver Segments During Laparoscopic Anatomical Liver Resection: Pilot Feasibility Study
    Ueno, Masaki
    Hayami, Shinya
    Sonomura, Tetsuo
    Kawai, Manabu
    Hirono, Seiko
    Okada, Ken-ichi
    Tanaka, Ryota
    Yamaue, Hiroki
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2019, 29 (04): : 242 - 246
  • [26] Clinical effects of the use of the indocyanine green fluorescence imaging technique in laparoscopic partial liver resection
    Itoh, Shinji
    Tomiyama, Takahiro
    Morinaga, Akinari
    Kurihara, Takeshi
    Nagao, Yoshihiro
    Toshima, Takeo
    Morita, Kazutoyo
    Harada, Noboru
    Mori, Masaki
    Yoshizumi, Tomoharu
    ANNALS OF GASTROENTEROLOGICAL SURGERY, 2022, 6 (05): : 688 - 694
  • [27] Laparoscopic Anatomical Segment VII Resection for Hepatocellular Carcinoma Using the Glissonian Approach with Indocyanine Green Dye Fluorescence
    Jun-ming He
    Zhi-peng Zhen
    Qing Ye
    Jia-qiang Mo
    Gui-hao Chen
    Jian-xin Peng
    Journal of Gastrointestinal Surgery, 2020, 24 : 1228 - 1229
  • [28] Successful laparoscopic resection of gastric lymphangioma under the intraoperative guidance of indocyanine green fluorescence imaging: A case report
    Umino, Ryosuke
    Urabe, Masayuki
    Ohkura, Yu
    Haruta, Shusuke
    Ueno, Masaki
    Udagawa, Harushi
    ASIAN JOURNAL OF ENDOSCOPIC SURGERY, 2022, 15 (01) : 176 - 179
  • [29] Laparoscopic Anatomical Segment VII Resection for Hepatocellular Carcinoma Using the Glissonian Approach with Indocyanine Green Dye Fluorescence
    He, Jun-ming
    Zhen, Zhi-peng
    Ye, Qing
    Mo, Jia-qiang
    Chen, Gui-hao
    Peng, Jian-xin
    JOURNAL OF GASTROINTESTINAL SURGERY, 2020, 24 (05) : 1228 - 1229
  • [30] Indocyanine green staining for intraoperative perfusion assessment
    Salehi, Omid
    Kazakova, Vera
    Vega, Eduardo A.
    Conrad, Claudius
    MINERVA SURGERY, 2021, 76 (03): : 220 - 228