Optimal Dosage of Indocyanine Green Fluorescence for Intraoperative Positive Staining in Laparoscopic Anatomical Liver Resection

被引:5
|
作者
Kasai, Meidai [1 ]
Aihara, Tsukasa [1 ]
Ikuta, Shinichi [1 ]
Nakajima, Takayoshi [2 ]
Yamanaka, Naoki [1 ]
机构
[1] Meiwa Hosp, Dept Surg, Nishinomiya, Hyogo, Japan
[2] Meiwa Hosp, Dept Surg, Nishinomiya, Japan
关键词
roc curve analysis; positive staining; indocyanine green; fluorescence imaging technology; laparoscopic anatomical liver resection; NAVIGATION;
D O I
10.7759/cureus.46771
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionFluorescence imaging technology, specifically utilizing indocyanine green (ICG), has emerged as a valuable tool in laparoscopic hepatectomy. In particular, laparoscopic anatomical liver resection (ALR) has benefited from the implementation of both positive and negative staining methods. A case series study reported a success rate of 53% for the positive staining method, citing potential issues regarding the proper ICG dosage needed for accurate fluorescence. Thus, it is crucial to conduct research to investigate the optimal dosage for ICG-positive staining in clinical practice to maximize the benefits of this technique.Materials and methodsThis retrospective study was conducted at a single center, Meiwa Hospital, and received approval from the hospital's ethics committee in accordance with the Helsinki Declaration. We reviewed the records of 264 patients who underwent open and laparoscopic hepatectomies for benign and malignant liver diseases from January 2019 to January 2023. Of these, 18 patients who underwent laparoscopic ALR with the ICG-positive staining method were evaluated. Fluorescence-emitting segmental borders were assessed immediately after puncture (first stage) and during parenchymal dissection (second stage). In the first stage, we evaluated the intensity of fluorescence emission, categorizing it as "strong" or "weak." The absence of visible fluorescence emission was considered a puncture failure. During the second stage of evaluation, from parenchymal resection to completion, we assessed the sustainability of fluorescence emission, defining it as "clear" or "contaminated." Both evaluations were subjectively judged by three surgeons at our center. The ICG quantity per targeted portal vein-bearing liver volume (mg/100 mL) was calculated for each patient, and the optimal dosage was determined using receiver operating characteristic (ROC) curve analysis. To ascertain the minimum value for adequate fluorescence emission intensity, ROC curve analysis was performed to discriminate between binary outcomes of "strong" or "weak" emission. Furthermore, to establish the maximum value for maintaining a clear fluorescence border, ROC curve analysis was conducted to discriminate between "clear" and "contaminated" during the second evaluation.ResultsAmong the 18 successful puncture cases, the first-stage evaluation of fluorescence intensity revealed 14 punctures with "strong" intensity and four punctures with "weak" intensity. In the second-stage evaluation, 13 cases demonstrated "clear" borders, while five cases exhibited "contaminated" borders. ROC curve analysis was performed to determine the optimal ICG dose for adequate fluorescence intensity and preservation of clear borders during dissection. The analysis indicated that the appropriate ICG dose for achieving optimal intensity was 0.028 mg/100 mL (area under the curve [AUC]: 0.893), while the dose that prevented contamination of fluorescence in non-target areas until after dissection was 0.083 mg/100 mL (AUC: 0.723).ConclusionsLaparoscopic anatomical resection using the positive staining method requires an optimal ICG dosage of 0.028-0.083 mg per 100 mL of liver volume. By employing this methodology, more precise and safer laparoscopic anatomical resections can be conducted, thereby enhancing the safety of the surgical procedure for patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Laparoscopic anatomical liver resection for malignancies using positive or negative staining technique with intraoperative indocyanine green-fluorescence imaging
    Felli, Emanuele
    Ishizawa, Takeaki
    Cherkaoui, Zineb
    Diana, Michele
    Tripon, Simona
    Baumert, Thomas F.
    Schuster, Catherine
    Pessaux, Patrick
    HPB, 2021, 23 (11) : 1647 - 1655
  • [2] Ultrasound-Guided Preoperative Positive Percutaneous Indocyanine Green Fluorescence Staining for Laparoscopic Anatomical Liver Resection
    Aoki, Takeshi
    Koizumi, Tomotake
    Mansour, Doaa A.
    Fujimori, Akira
    Kusano, Tomokazu
    Matsuda, Kazuhiro
    Tashiro, Yoshihiko
    Watanabe, Makoto
    Otsuka, Koji
    Murakami, Masahiko
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2020, 230 (03) : E7 - E12
  • [3] Laparoscopic anatomical liver resection using indocyanine green fluorescence imaging
    Urade, Takeshi
    Sawa, Hidehiro
    Iwatani, Yoshiteru
    Abe, Tomoki
    Fujinaka, Ryosuke
    Murata, Koichi
    Mii, Yasuhiko
    Man-i, Mariko
    Oka, Shigeteru
    Kuroda, Daisuke
    ASIAN JOURNAL OF SURGERY, 2020, 43 (01) : 362 - 368
  • [4] A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII
    Jiang, Zedong
    Zhou, Bo
    Zheng, Xiang
    Li, Guogang
    Gao, Zhenzhen
    Tian, Yang
    Shao, Chunlong
    Xu, Shaoyan
    Yan, Sheng
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [5] Comparing the accuracy of positive and negative indocyanine green staining in guiding laparoscopic anatomical liver resection: protocol for a randomised controlled trial
    Alomari, Malek Abdallah Muflih
    Wakabayashi, Taiga
    Colella, Marco
    Mishima, Kouhei
    Fujiyama, Yoshiki
    Ababneh, Ebaa
    Wakabayashi, Go
    BMJ OPEN, 2023, 13 (09):
  • [6] Comparing the accuracy of positive and negative indocyanine green staining in guiding laparoscopic anatomical liver resection: protocol for a randomised controlled trial
    Alomari, Malek Abdallah Muflih
    Wakabayashi, Taiga
    Colella, Marco
    Mishima, Kohei
    Fujiyama, Yoshiki
    Ababneh, Ebaa
    Wakabayash, Go
    BMJ OPEN, 2023, 13 (12):
  • [7] Laparoscopic Anatomical Liver Resection Using Liver Mapping of Incidental Indocyanine Green Fluorescence due to Cholestasis
    Tomioka, Kodai
    Aoki, Takeshi
    Tashiro, Yoshihiko
    Kusano, Tomokazu
    Matsuda, Kazuhiro
    Yamada, Kosuke
    Nogaki, Koji
    Wada, Yusuke
    Shibata, Hideki
    Hirai, Takahito
    Yamazaki, Tatsuya
    Saito, Kazuhiko
    Uchida, Marie
    Nagaishi, Shodai
    Fujimori, Akira
    Enami, Yuta
    ANTICANCER RESEARCH, 2023, 43 (12) : 5583 - 5588
  • [8] Indocyanine green fluorescence imaging techniques and interventional radiology during laparoscopic anatomical liver resection (with video)
    Masaki Ueno
    Shinya Hayami
    Tetsuo Sonomura
    Ryota Tanaka
    Manabu Kawai
    Seiko Hirono
    Ken-ichi Okada
    Hiroki Yamaue
    Surgical Endoscopy, 2018, 32 : 1051 - 1055
  • [9] Indocyanine green fluorescence imaging techniques and interventional radiology during laparoscopic anatomical liver resection (with video)
    Ueno, Masaki
    Hayami, Shinya
    Sonomura, Tetsuo
    Tanaka, Ryota
    Kawai, Manabu
    Hirono, Seiko
    Okada, Ken-ichi
    Yamaue, Hiroki
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2018, 32 (02): : 1051 - 1055
  • [10] Laparoscopic Anatomical Liver Resection of Segment 7 with Intraoperative Portal Venography Guidance Using Indocyanine Green(ICG)Fluorescence-Video Article
    Diao, Jingfang
    He, Junming
    BRITISH JOURNAL OF SURGERY, 2019, 106 : 94 - 94