Radiation exposure in cone beam CT measured using a MOSFET and RPLGD dosimeter and Monte Carlo simulation in phantom

被引:0
|
作者
Kweon, Dae Cheol [1 ]
机构
[1] Shinhan Univ, Dept Radiol Sci, Uijongbu, South Korea
关键词
Absorbed dose; cone beam CT; radiation dose; MOSFET; RPLGD; PANORAMIC RADIOGRAPHY; IMAGE QUALITY; TOMOGRAPHY; ORGAN; VALIDATION;
D O I
10.3233/XST-230026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Due to the wide application of the cone beam computed tomography (CBCT) in clinical practice, it is important to assess radiation dose of CBCT more accurately and efficiently in different clinical applications. OBJECTIVE: This study aims to calculate effective and absorbed doses in CBCT measured in an anthropomorphic phantom using computer-based Monte Carlo (PCXMC) software, and to conduct comparative evaluations of MOSFET (metal-oxide-semiconductor field-effect transistor) and radiophotoluminescence glass dosimeters (RPLGD). METHODS: Effective and absorbed organ doses are compared with those obtained using MOSFET and RPLGD dosimetry in an anthropomorphic phantom given the same exposure settings. Effective and absorbed organ doses from CBCT during scout and main projections are calculated using PCXMC and PCXMCRotation software, respectively. RESULTS: The mean effective dose from CBCT calculated using PCXMC software is 233.8 mu Sv, while the doses calculated using dosimetry (MOSFET and RPLGD) are 266.67 mu Sv and 268.78 mu Sv, respectively. The X-ray source variation is 0.79%. The prescription limits based on the Friedman test for MOSFET and RPLGD pre-points (i.e., in an analytical analysis of diagnostic names in CBCT) are not statistically significant. The calculated correlation coefficient between MOSFET- and RPLGD-derived absorbed dose values with respect to a field of view CBCT parameter of 17x13.5mm is r = 0.8623. CONCLUSIONS: The study demonstrates that the PCXMC software may be used as an alternative to MOSFET and RPLGD dosimetry for effective and absorbed organ dose estimation in CBCT conducted with a large FOV in an anthropomorphic phantom.
引用
收藏
页码:837 / 852
页数:16
相关论文
共 50 条
  • [31] Study On the CT Radiation Attenuation Characteristics of Human Body for Phantom Design Using Monte Carlo Simulations
    Liu, H.
    Gao, Y.
    Zhuo, W.
    Wu, J.
    Xu, X.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [32] Characterization of scatter in cone-beam CT breast imaging: Comparison of experimental measurements and Monte Carlo simulation
    Chen, Yu
    Liu, Bob
    O'Connor, J. Michael
    Didier, Clay S.
    Glick, Stephen J.
    [J]. MEDICAL PHYSICS, 2009, 36 (03) : 857 - 869
  • [33] Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT
    Lazos, Dimitrios
    Williamson, Jeffrey F.
    [J]. MEDICAL PHYSICS, 2010, 37 (10) : 5456 - 5470
  • [34] Monte Carlo Dosimetry for a Dedicated Cone-Beam CT Head Scanner
    Sisniega, A.
    Zbijewski, W.
    Xu, J.
    Dang, H.
    Stayman, J. W.
    Aygun, N.
    Koliatsos, V. E.
    Wang, X.
    Foos, D. H.
    Siewerdsen, J. H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3681 - 3682
  • [35] Experimental Evaluation of Dose Calculation Using Mega-Voltage Cone Beam CT with MOSFET Detector in an Anthropomorphic Phantom
    Matsubara, K.
    Kohno, R.
    Honmatsu, K.
    Kitou, S.
    Kawashima, M.
    Ogino, T.
    Saitoh, H.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [36] Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom
    Toshimune Ito
    Hirotatsu Tsuchikame
    Hajime Ichikawa
    Masahisa Onoguchi
    Koichi Okuda
    Takayuki Shibutani
    Noriyo Yokotsuka
    Hiroshi Tomizawa
    [J]. Radiological Physics and Technology, 2021, 14 : 336 - 344
  • [37] Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom
    Ito, Toshimune
    Tsuchikame, Hirotatsu
    Ichikawa, Hajime
    Onoguchi, Masahisa
    Okuda, Koichi
    Shibutani, Takayuki
    Yokotsuka, Noriyo
    Tomizawa, Hiroshi
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (03) : 336 - 344
  • [38] Investigation on the resolution of a micro cone beam CT scanner scintillating detector using Monte Carlo methods
    Volken, W.
    Zulliger, M. A.
    Koller, B.
    Manser, P.
    Fix, M. K.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 53 : 17 - 24
  • [39] A Monte Carlo Simulation of the Imaging of Low MV Cone Beam Computed Tomography
    Chen, C.
    Feng, W.
    Chen, H.
    Chao, K.
    Chang, J.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [40] Determination of Exposure during Handling of 125I Seed Using Thermoluminescent Dosimeter and Monte Carlo Method Based on Computational Phantom
    Poorbaygi, Hosein
    Salimi, Seyed Mostafa
    Torkzadeh, Falamarz
    Hamidi, Saeid
    Sheibani, Shahab
    [J]. JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2023, 48 (04): : 197 - 203