Radiation exposure in cone beam CT measured using a MOSFET and RPLGD dosimeter and Monte Carlo simulation in phantom

被引:0
|
作者
Kweon, Dae Cheol [1 ]
机构
[1] Shinhan Univ, Dept Radiol Sci, Uijongbu, South Korea
关键词
Absorbed dose; cone beam CT; radiation dose; MOSFET; RPLGD; PANORAMIC RADIOGRAPHY; IMAGE QUALITY; TOMOGRAPHY; ORGAN; VALIDATION;
D O I
10.3233/XST-230026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Due to the wide application of the cone beam computed tomography (CBCT) in clinical practice, it is important to assess radiation dose of CBCT more accurately and efficiently in different clinical applications. OBJECTIVE: This study aims to calculate effective and absorbed doses in CBCT measured in an anthropomorphic phantom using computer-based Monte Carlo (PCXMC) software, and to conduct comparative evaluations of MOSFET (metal-oxide-semiconductor field-effect transistor) and radiophotoluminescence glass dosimeters (RPLGD). METHODS: Effective and absorbed organ doses are compared with those obtained using MOSFET and RPLGD dosimetry in an anthropomorphic phantom given the same exposure settings. Effective and absorbed organ doses from CBCT during scout and main projections are calculated using PCXMC and PCXMCRotation software, respectively. RESULTS: The mean effective dose from CBCT calculated using PCXMC software is 233.8 mu Sv, while the doses calculated using dosimetry (MOSFET and RPLGD) are 266.67 mu Sv and 268.78 mu Sv, respectively. The X-ray source variation is 0.79%. The prescription limits based on the Friedman test for MOSFET and RPLGD pre-points (i.e., in an analytical analysis of diagnostic names in CBCT) are not statistically significant. The calculated correlation coefficient between MOSFET- and RPLGD-derived absorbed dose values with respect to a field of view CBCT parameter of 17x13.5mm is r = 0.8623. CONCLUSIONS: The study demonstrates that the PCXMC software may be used as an alternative to MOSFET and RPLGD dosimetry for effective and absorbed organ dose estimation in CBCT conducted with a large FOV in an anthropomorphic phantom.
引用
收藏
页码:837 / 852
页数:16
相关论文
共 50 条
  • [41] Assessment of OSL Dosimeter Technology in the Validation of a Monte Carlo Radiation Transport Code for CT Dosimetry
    Carver, D.
    Kost, S.
    Pickens, D.
    Price, R.
    Stabin, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 404 - 405
  • [42] Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast
    Sechopoulos, Ioannis
    Vedantham, Srinivasan
    Suryanarayanan, Sankararaman
    D'Orsi, Carl J.
    Karellas, Andrew
    [J]. RADIOLOGY, 2008, 247 (01) : 98 - 105
  • [43] Monte Carlo simulation of the radiolysis of the ceric sulfate dosimeter by low linear energy transfer radiation
    Plante, Ianik
    Tippayamontri, Thititip
    Autsavapromporn, Narongchai
    Meesungnoen, Jintana
    Jay-Gerin, Jean-Paul
    [J]. Canadian Journal of Chemistry, 2012, 90 (09) : 717 - 723
  • [44] Monte Carlo simulation of the radiolysis of the ceric sulfate dosimeter by low linear energy transfer radiation
    Plante, Ianik
    Tippayamontri, Thititip
    Autsavapromporn, Narongchai
    Meesungnoen, Jintana
    Jay-Gerin, Jean-Paul
    [J]. CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 2012, 90 (09): : 717 - 723
  • [45] Evaluation of Scattering in Cone-Beam Breast Computed Tomography: A Monte Carlo and Experimental Phantom Study
    Mettivier, Giovanni
    Russo, Paolo
    Lanconelli, Nico
    Lo Meo, Sergio
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (05) : 2510 - 2517
  • [46] Evaluation of Scattering in Cone-Beam Breast Computed Tomography: a Monte Carlo and experimental phantom study
    Mettivier, Giovanni
    Russo, Paolo
    Lanconelli, Nico
    Lo Meo, Sergio
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2930 - +
  • [47] Cone-Beam-CT Dose Simulation of Dental Cone-Beam-CT Using GMctdospp
    Voigt, J.
    Wulff, J.
    Guldner, C.
    Fiebich, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3399 - +
  • [48] Cone-beam CT dosimetry for the positional variation in isocenter: A Monte Carlo study
    Chow, James C. L.
    [J]. MEDICAL PHYSICS, 2009, 36 (08) : 3512 - 3520
  • [49] Monte Carlo modeling for dose assessment in cone beam CT for oral and maxillofacial applications
    Zhang, G.
    Marshall, N.
    Bogaerts, R.
    Jacobs, R.
    Bosmans, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (07)
  • [50] Monte Carlo study of Cone-Beam CT dose variation with patient size
    Joshi, K.
    Marchant, T.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S516 - S517