Considerations for hyperpolarized 13C MR at reduced field: Comparing 1.5T versus 3T

被引:1
|
作者
Traechtler, Julia [1 ]
Fuetterer, Maximilian [1 ]
Albannay, Mohammed M. [1 ,2 ]
Hoh, Tobias [1 ]
Kozerke, Sebastian [1 ,3 ]
机构
[1] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Lab Phys Chem, Zurich, Switzerland
[3] Univ & ETH Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
基金
欧盟地平线“2020”;
关键词
1.5T versus 3T; field comparison; field inhomogeneities; signal-to-noise; ratio; TO-NOISE RATIO; PULSE SEQUENCE; RF COILS; LUNG MRI; EXCITATION; SURFACE;
D O I
10.1002/mrm.29579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In contrast to conventional MR, signal-to-noise ratio (SNR) is not linearly dependent on field strength in hyperpolarized MR, as polarization is generated outside the MR system. Moreover, field inhomogeneity-induced artifacts and other practical limitations associated with field strengths =3T are alleviated at lower fields. The potential of hyperpolarized 13C spectroscopy and imaging at 1.5T versus 3T is demonstrated in silico, in vitro, and in vivo for applications on clinical MR systems. Theory and Methods: Theoretical noise and SNR behavior at different field strengths are investigated based on simulations. A thorough field comparison between 1.5T and 3T is performed using thermal and hyperpolarized 13C spectroscopy and imaging. Cardiac in vivo data is obtained in pigs using hyperpolarized [1-13C]pyruvate spectroscopy and imaging at 1.5T and 3T. Results: Based on theoretical considerations and simulations, the SNRof hyperpolarized MR at identical acquisition bandwidths is independent of the field strength for typical coil setups, while adaptively changing the acquisition bandwidth proportional to the static magnetic field allows for net SNR gains of up to 40% at 1.5T compared to 3T. In vitro 13C data verified these considerations with less than 7% deviation. In vivo feasibility of hyperpolarized [1-13C]pyruvate dynamic metabolic spectroscopy and imaging at 1.5T is demonstrated in the pig heart with comparable SNR between 1.5T and 3T while B0 artifacts are noticeably reduced at 1.5T. Conclusion: Hyperpolarized 13C MR at lower field strengths is favorable in terms of SNR and off-resonance effects, which makes 1.5T a promising alternative to 3T, especially for clinical cardiac metabolic imaging.
引用
收藏
页码:1945 / 1960
页数:16
相关论文
共 50 条
  • [11] Quantification of pulsed saturation transfer at 1.5T and 3T
    Chan, Rachel W.
    Myrehaug, Sten
    Stanisz, Greg J.
    Sahgal, Arjun
    Lau, Angus Z.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (05) : 1684 - 1699
  • [12] 1.5T versus 3T MRI for targeting subthalamic nucleus for deep brain stimulation
    Cheng, Cheng-Hsin
    Huang, Hsing-Ming
    Lin, Hung-Lin
    Chiou, Shang-Ming
    BRITISH JOURNAL OF NEUROSURGERY, 2014, 28 (04) : 467 - 470
  • [13] Comparison of 1.5T and 3T 1H MR spectroscopy for human brain tumors
    Kim, Ji-hoon
    Chang, Kee-Hyun
    Na, Dong Gyu
    Song, In Chan
    Kim, Seung Ja
    Kwon, Bae Ju
    Han, Moon Hee
    KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (03) : 156 - 161
  • [14] Neurovascular contact in trigeminal neuralgia. A comparison between 3T and 1.5T MR imaging
    Echeveste, B. E.
    Minguez, A.
    Imaz, L.
    Trzeciak, M.
    Barriobero, N.
    Arregui, A.
    Trevino, C.
    Garcia de Eulate, R.
    Dominguez, P.
    Zubieta, J. L.
    Martinez-Vila, E.
    Irimia, P.
    CEPHALALGIA, 2015, 35 : 254 - 254
  • [15] Optimisation of Gadolinium and Iodinated Contrast Ratio for 1.5T and 3T MR Arthrography: An In Vitro Study
    Mo, C. K. M.
    Cho, K. Y.
    Au, A. K. Y.
    Chu, C. Y.
    HONG KONG JOURNAL OF RADIOLOGY, 2021, 24 (03): : 201 - 207
  • [16] Estimation of 3T MR Images from 1.5T Images Regularized with Physics Based Constraint
    Kaur, Prabhjot
    Minhas, Atul Singh
    Ahuja, Chirag Kamal
    Sao, Anil Kumar
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT X, 2023, 14229 : 132 - 141
  • [17] Inter-field strength agreement of left atrial assessment at 1.5T and 3T
    Alfuhied, A.
    Ayton, S.
    Gulsin, G. S.
    Parke, K. S.
    Wormleighton, J. V.
    Moss, A.
    Graham-Brown, M. P. M.
    Arnold, J. R.
    McCann, G. P.
    Singh, A.
    EUROPEAN HEART JOURNAL, 2022, 43 : 218 - 218
  • [18] 1.5t、3t电弧炉烟尘治理
    张顺喜
    杨洁
    工业安全与环保, 2009, 35 (06) : 9 - 11
  • [19] 2D RF pulse design for optimized reduced field-of-view imaging at 1.5T and 3T
    Eren, Orhun Caner
    Barlas, Bahadir Alp
    Saritas, Emine Ulku
    MAGNETIC RESONANCE IMAGING, 2022, 85 : 210 - 216
  • [20] Carotid MRI Detection of Intraplaque Hemorrhage at 3T and 1.5T
    McNally, J. Scott
    Yoon, Hyo-Chun
    Kim, Seong-Eun
    Narra, Krishna K.
    McLaughlin, Michael S.
    Parker, Dennis L.
    Treiman, Gerald S.
    JOURNAL OF NEUROIMAGING, 2015, 25 (03) : 390 - 396