Considerations for hyperpolarized 13C MR at reduced field: Comparing 1.5T versus 3T

被引:1
|
作者
Traechtler, Julia [1 ]
Fuetterer, Maximilian [1 ]
Albannay, Mohammed M. [1 ,2 ]
Hoh, Tobias [1 ]
Kozerke, Sebastian [1 ,3 ]
机构
[1] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Lab Phys Chem, Zurich, Switzerland
[3] Univ & ETH Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
基金
欧盟地平线“2020”;
关键词
1.5T versus 3T; field comparison; field inhomogeneities; signal-to-noise; ratio; TO-NOISE RATIO; PULSE SEQUENCE; RF COILS; LUNG MRI; EXCITATION; SURFACE;
D O I
10.1002/mrm.29579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In contrast to conventional MR, signal-to-noise ratio (SNR) is not linearly dependent on field strength in hyperpolarized MR, as polarization is generated outside the MR system. Moreover, field inhomogeneity-induced artifacts and other practical limitations associated with field strengths =3T are alleviated at lower fields. The potential of hyperpolarized 13C spectroscopy and imaging at 1.5T versus 3T is demonstrated in silico, in vitro, and in vivo for applications on clinical MR systems. Theory and Methods: Theoretical noise and SNR behavior at different field strengths are investigated based on simulations. A thorough field comparison between 1.5T and 3T is performed using thermal and hyperpolarized 13C spectroscopy and imaging. Cardiac in vivo data is obtained in pigs using hyperpolarized [1-13C]pyruvate spectroscopy and imaging at 1.5T and 3T. Results: Based on theoretical considerations and simulations, the SNRof hyperpolarized MR at identical acquisition bandwidths is independent of the field strength for typical coil setups, while adaptively changing the acquisition bandwidth proportional to the static magnetic field allows for net SNR gains of up to 40% at 1.5T compared to 3T. In vitro 13C data verified these considerations with less than 7% deviation. In vivo feasibility of hyperpolarized [1-13C]pyruvate dynamic metabolic spectroscopy and imaging at 1.5T is demonstrated in the pig heart with comparable SNR between 1.5T and 3T while B0 artifacts are noticeably reduced at 1.5T. Conclusion: Hyperpolarized 13C MR at lower field strengths is favorable in terms of SNR and off-resonance effects, which makes 1.5T a promising alternative to 3T, especially for clinical cardiac metabolic imaging.
引用
收藏
页码:1945 / 1960
页数:16
相关论文
共 50 条
  • [21] Comparison of 1.5T and 3T in assessment of suspicious breast lesions
    SK Arcot Ragupathy
    T Gagliardi
    TW Redpath
    S Flynn
    B Jagpal
    JKP Begley
    FJ Gilbert
    Breast Cancer Research, 12
  • [22] Comparison of 1.5T and 3T in assessment of suspicious breast lesions
    Ragupathy, S. K. Arcot
    Gagliardi, T.
    Redpath, T. W.
    Flynn, S.
    Jagpal, B.
    Begley, J. K. P.
    Gilbert, F. J.
    BREAST CANCER RESEARCH, 2010, 12
  • [23] 3T versus 1.5T MR angiography in peripheral arterial occlusive disease: an equivalence trial in comparison with digital subtraction angiography
    Harrie van den Bosch
    Jos J Westenberg
    Lucien E Duijm
    Alette Daniels-Gooszen
    Erik Kersten
    Philippe W Cuypers
    Albert de Roos
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [24] REDUCED-BANDWIDTH MR IMAGING OF THE HEAD AT 1.5T
    SIMON, JH
    FOSTER, TH
    KETONEN, L
    TOTTERMAN, S
    SZUMOWSKI, J
    KIDO, DK
    MANZIONE, JV
    JOY, SE
    RADIOLOGY, 1989, 172 (03) : 771 - 775
  • [25] MR proton spectroscopy for myocardial lipid deposition quantification: A quantitative comparison between 1.5T and 3T
    Venkatesh, Bharath Ambale
    Lima, Joao A. C.
    Bluemke, David A.
    Lai, Shenghan
    Steenbergen, Charles
    Liu, Chia-Ying
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1222 - 1230
  • [26] Brain MRI Lesion Load at 1.5T and 3T versus Clinical Status in Multiple Sclerosis
    Stankiewicz, James M.
    Glanz, Bonnie I.
    Healy, Brian C.
    Arora, Ashish
    Neema, Mohit
    Benedict, Ralph H. B.
    Guss, Zachary D.
    Tauhid, Shahamat
    Buckle, Guy J.
    Houtchens, Maria K.
    Khoury, Samia J.
    Weiner, Howard L.
    Guttmann, Charles R. G.
    Bakshi, Rohit
    JOURNAL OF NEUROIMAGING, 2011, 21 (02) : e50 - e56
  • [27] MR Spectroscopic Imaging of Benign Prostatic Tissue: Findings at 3T Compared to 1.5T Initial Experience
    Chitkara, M.
    Westphalen, A.
    Kurhanewicz, J.
    Qayyum, A.
    Poder, L.
    Reed, G.
    Coakley, F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [28] Comparing 3T and 1.5T MRI for Mapping Hippocampal Atrophy in the Alzheimer's Disease Neuroimaging Initiative
    Chow, N.
    Hwang, K. S.
    Hurtz, S.
    Green, A. E.
    Somme, J. H.
    Thompson, P. M.
    Elashoff, D. A.
    Jack, C. R.
    Weiner, M.
    Apostolova, L. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (04) : 653 - 660
  • [29] T1 and T2 relaxivity of intracellular and extracellular USPIO at 1.5T and 3T clinical MR scanning
    Gerhard H. Simon
    Jan Bauer
    Olaf Saborovski
    Yanjun Fu
    Claire Corot
    Michael F. Wendland
    Heike E. Daldrup-Link
    European Radiology, 2006, 16 : 738 - 745
  • [30] T1 and T2 relaxivity of intracellular and extracellular USPIO at 1.5T and 3T clinical MR scanning
    Simon, GH
    Bauer, J
    Saborovski, O
    Fu, YJ
    Corot, C
    Wendland, MF
    Daldrup-Link, HE
    EUROPEAN RADIOLOGY, 2006, 16 (03) : 738 - 745