Application of the long axial field-of-view PET/CT with low-dose [18F]FDG in melanoma

被引:36
|
作者
Sachpekidis, Christos [1 ]
Pan, Leyun [1 ]
Kopp-Schneider, Annette [2 ]
Weru, Vivienn [2 ]
Hassel, Jessica C. C. [3 ,4 ]
Dimitrakopoulou-Strauss, Antonia [1 ]
机构
[1] German Canc Res Ctr, Clin Cooperat Unit Nucl Med, Neuenheimer Feld 280, D-69210 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Biostat, Heidelberg, Germany
[3] Univ Hosp Heidelberg, Skin Canc Ctr, Dept Dermatol, Heidelberg, Germany
[4] Natl Ctr Tumor Dis Heidelberg, Heidelberg, Germany
关键词
Melanoma; LAFOV PET; F-18]FDG; Total body; Whole-body; SUV; FDG PET/CT; EQUIVALENCE; PROPORTIONS; TOMOGRAPHY; DIFFERENCE;
D O I
10.1007/s00259-022-06070-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AimThe recent introduction of long axial field-of-view (LAFOV) PET/CT scanners has yielded very promising results regarding image quality and sensitivity in oncological patients. We, herein, aim to determine an appropriate acquisition time range for the new long axial field of view Biograph Vision Quadra PET/CT (Siemens Healthcare) using low dose [F-18]FDG activity in a group of melanoma patients. MethodologyForty-nine melanoma patients were enrolled in the study. All patients underwent total body PET/CT from the top of the head through the feet in two bed positions (field-of-view 106 cm) after i.v. injection of 2.0 MBq/kg [F-18]FDG. The PET images of the first bed position (head to upper thigh; PET-10) were reconstructed and further split into 8-min (PET-8), 6-min (PET-6), 5-min (PET-5), 4-min (PET-4), and 2-min (PET-2) duration groups. Comparisons were performed between the different reconstructed scan times with regard to the visual evaluation of the PET/CT scans using the PET-10 images as reference and by calculating the 95%-CI for the differences between different time acquisitions. Moreover, objective evaluation of PET/CT image quality was performed based on SUV calculations of tumor lesions and background, leading to calculation of liver signal-to-noise ratio (SNR), and tumor-to-background ratio (TBR). ResultsA total of 60 scans were evaluated. Concerning visual analysis, 49/60 (81.7%) PET-10 scans were pathological, while the respective frequencies were 49/60 (81.7%) for PET-8 (95%-CI: - 0.0602-0.0602), 49/60 (81.7%) for PET-6 (95%-CI: - 0.0602-0.0602), 48/60 (80%) for PET-5 (95%-CI: - 0.0445-0.0886), 46/60 (76.7%) for PET-4 (95%-CI: - 0.0132-0.1370), and 45/60 (75%) for PET-2 (95%-CI: 0.0025-0.1593). In 18 PET-10 scans, the extent of metastatic involvement was very large, rendering the accurate calculation of [F-18]FDG-avid tumor lesions very complicated. In the remaining 42 PET-10 scans, for which the exact calculation of tumor lesions was feasible, a total of 119 tumor lesions were counted, and the respective lesion detection rates for shorter acquisitions were as follows: 97.5% (116/119) for PET-8 (95%-CI: 0-1), 95.0% (113/119) for PET-6 (95%-CI: 0-1), 89.9% (107/119) for PET-5 (95%-CI: 0-2), 83.2% (99/119) for PET-4 (95%-CI: 1-2), and 73.9% (88/119) for PET-2 (95%-CI: 2-4). With regard to objective image quality evaluations, as a general trend, the reduction of acquisition time was associated with a decrease of liver SNR and a decrease of TBR, although in lesion-based analysis the change in TBR and tumor SUVmean values was non-significant up to 6 and 5 min acquisitions, respectively. ConclusionsIn melanoma, low-dose LAFOV PET/CT imaging is feasible and can reduce the total scan time from head to upper thigh up to 5 min providing comparable diagnostic data to standard lengths of acquisition. This may have significant implications for the diagnostic work-up of patients with melanoma, given the need for true whole-body imaging in this type of cancer.
引用
收藏
页码:1158 / 1167
页数:10
相关论文
共 50 条
  • [41] Whole-Body [18F]FDG-PET/MRI vs. [18F]FDG-PET/CT in Malignant Melanoma
    Dominik Berzaczy
    Barbara Fueger
    Christoph Hoeller
    Alexander R. Haug
    Anton Staudenherz
    Gundula Berzaczy
    Michael Weber
    Marius E. Mayerhoefer
    Molecular Imaging and Biology, 2020, 22 : 739 - 744
  • [42] Whole-Body [18F]FDG-PET/MRI vs. [18F]FDG-PET/CT in Malignant Melanoma
    Berzaczy, Dominik
    Fueger, Barbara
    Hoeller, Christoph
    Haug, Alexander R.
    Staudenherz, Anton
    Berzaczy, Gundula
    Weber, Michael
    Mayerhoefer, Marius E.
    MOLECULAR IMAGING AND BIOLOGY, 2020, 22 (03) : 739 - 744
  • [43] Robustness study on radiomic features in [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Vuong, D.
    Bogowicz, M.
    Huellner, M.
    Veit-Haibach, P.
    Andratschke, N.
    Unkelbach, J.
    Guckenberger, M.
    Tanadini-Lang, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1159 - S1159
  • [44] Interchangeability of radiomic features between [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Diem Vuong
    Tanadini-Lang, Stephanie
    Huellner, Martin W.
    Veit-Haibach, Patrick
    Unkelbach, Jan
    Andratschke, Nicolaus
    Kraft, Johannes
    Guckenberger, Matthias
    Bogowicz, Marta
    MEDICAL PHYSICS, 2019, 46 (04) : 1677 - 1685
  • [45] Clinical application of [18F]FDG PET/CT in follicular lymphoma
    Diaz-Silvan, A.
    Oton-Sanchez, L. F.
    Caresia-Aroztegui, A. P.
    Cozar-Santiago, M. del Puig
    Orcajo-Rincon, J.
    De Arcocha-Torres, M.
    Delgado-Bolton, R. C.
    Cabello-Garcia, D.
    SociedadEspa, Sociedad Espanola de Medicina Nuclear e Imagen Molecular
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2022, 41 (03): : 202 - 212
  • [46] Brain-Only Imaging on Long Axial Field-of-View PET/CT
    Khan, J.
    Willson, T.
    Davis, N.
    Holman, B. F.
    Ferreira, B.
    McCool, D.
    Edwards, J.
    Szyszko, T.
    Wagner, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S702 - S703
  • [47] Using a novel long-axial field-of-view (LAFOV) PET/CT system for dual tracer scanning with [68Ga]Ga-PSMA-11 and [18F]FDG PET/CT for PSMA-therapy assessment
    Schepers, R.
    Zeimpekis, K.
    Viscione, M.
    Rominger, A.
    Afshar-Oromieh, A.
    Alberts, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S113 - S114
  • [48] Direct Reconstruction of Parametric [18F]FET Images on a Long-Axial Field-of-View PET Scanner in Patients with Suspected Glioma Recurrence
    Pyka, T.
    Mingels, C.
    Penner, J.
    Pigg, D.
    Krieger, K.
    Cumming, P.
    Rominger, A.
    Sari, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S473 - S473
  • [49] Semi-quantitative Evaluation of Image Quality in Low Dose 18F FDG PET/CT
    Kapur, S. C.
    Sinha, Arvind K.
    Sajjith, V. P.
    Teh, Donald
    Sharma, Vijay
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S344 - S344
  • [50] Ultra-low-dose CT for Long Axial Field of View PET/CT: A Phantom Study
    Mostafapour, S.
    Greuter, M.
    van Snick, P.
    van Sluis, J.
    Lammertsma, A. A.
    Tsoumpas, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S228 - S229