Application of the long axial field-of-view PET/CT with low-dose [18F]FDG in melanoma

被引:36
|
作者
Sachpekidis, Christos [1 ]
Pan, Leyun [1 ]
Kopp-Schneider, Annette [2 ]
Weru, Vivienn [2 ]
Hassel, Jessica C. C. [3 ,4 ]
Dimitrakopoulou-Strauss, Antonia [1 ]
机构
[1] German Canc Res Ctr, Clin Cooperat Unit Nucl Med, Neuenheimer Feld 280, D-69210 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Biostat, Heidelberg, Germany
[3] Univ Hosp Heidelberg, Skin Canc Ctr, Dept Dermatol, Heidelberg, Germany
[4] Natl Ctr Tumor Dis Heidelberg, Heidelberg, Germany
关键词
Melanoma; LAFOV PET; F-18]FDG; Total body; Whole-body; SUV; FDG PET/CT; EQUIVALENCE; PROPORTIONS; TOMOGRAPHY; DIFFERENCE;
D O I
10.1007/s00259-022-06070-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AimThe recent introduction of long axial field-of-view (LAFOV) PET/CT scanners has yielded very promising results regarding image quality and sensitivity in oncological patients. We, herein, aim to determine an appropriate acquisition time range for the new long axial field of view Biograph Vision Quadra PET/CT (Siemens Healthcare) using low dose [F-18]FDG activity in a group of melanoma patients. MethodologyForty-nine melanoma patients were enrolled in the study. All patients underwent total body PET/CT from the top of the head through the feet in two bed positions (field-of-view 106 cm) after i.v. injection of 2.0 MBq/kg [F-18]FDG. The PET images of the first bed position (head to upper thigh; PET-10) were reconstructed and further split into 8-min (PET-8), 6-min (PET-6), 5-min (PET-5), 4-min (PET-4), and 2-min (PET-2) duration groups. Comparisons were performed between the different reconstructed scan times with regard to the visual evaluation of the PET/CT scans using the PET-10 images as reference and by calculating the 95%-CI for the differences between different time acquisitions. Moreover, objective evaluation of PET/CT image quality was performed based on SUV calculations of tumor lesions and background, leading to calculation of liver signal-to-noise ratio (SNR), and tumor-to-background ratio (TBR). ResultsA total of 60 scans were evaluated. Concerning visual analysis, 49/60 (81.7%) PET-10 scans were pathological, while the respective frequencies were 49/60 (81.7%) for PET-8 (95%-CI: - 0.0602-0.0602), 49/60 (81.7%) for PET-6 (95%-CI: - 0.0602-0.0602), 48/60 (80%) for PET-5 (95%-CI: - 0.0445-0.0886), 46/60 (76.7%) for PET-4 (95%-CI: - 0.0132-0.1370), and 45/60 (75%) for PET-2 (95%-CI: 0.0025-0.1593). In 18 PET-10 scans, the extent of metastatic involvement was very large, rendering the accurate calculation of [F-18]FDG-avid tumor lesions very complicated. In the remaining 42 PET-10 scans, for which the exact calculation of tumor lesions was feasible, a total of 119 tumor lesions were counted, and the respective lesion detection rates for shorter acquisitions were as follows: 97.5% (116/119) for PET-8 (95%-CI: 0-1), 95.0% (113/119) for PET-6 (95%-CI: 0-1), 89.9% (107/119) for PET-5 (95%-CI: 0-2), 83.2% (99/119) for PET-4 (95%-CI: 1-2), and 73.9% (88/119) for PET-2 (95%-CI: 2-4). With regard to objective image quality evaluations, as a general trend, the reduction of acquisition time was associated with a decrease of liver SNR and a decrease of TBR, although in lesion-based analysis the change in TBR and tumor SUVmean values was non-significant up to 6 and 5 min acquisitions, respectively. ConclusionsIn melanoma, low-dose LAFOV PET/CT imaging is feasible and can reduce the total scan time from head to upper thigh up to 5 min providing comparable diagnostic data to standard lengths of acquisition. This may have significant implications for the diagnostic work-up of patients with melanoma, given the need for true whole-body imaging in this type of cancer.
引用
收藏
页码:1158 / 1167
页数:10
相关论文
共 50 条
  • [31] Ultra-low dose infection imaging of a newborn without sedation using long axial field-of-view PET/CT
    van Rijsewijk, N. D.
    van Leer, B.
    Ivashchenko, O. V.
    Scholvinck, E. H.
    van den Heuvel, F.
    van Snick, J. H.
    Slart, R. H. J. A.
    Noordzij, W.
    Glaudemans, A. W. J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (02) : 622 - 623
  • [32] [18F]FDG PET/CT in the Evaluation of Melanoma Patients Treated with Immunotherapy
    Mangas Losada, Maria
    Romero Robles, Leonardo
    Mendoza Melero, Alejandro
    Garcia Megias, Irene
    Villanueva Torres, Amos
    Garrastachu Zumaran, Puy
    Boulvard Chollet, Xavier
    Lopci, Egesta
    Ramirez Lasanta, Rafael
    Delgado Bolton, Roberto C.
    DIAGNOSTICS, 2023, 13 (05)
  • [33] Malignant Melanoma of Glans Penis Findings on 18F FDG PET/CT
    Sachani, Hemant
    Tripathy, Sarthak
    Shamim, Shamim Ahmed
    Rastogi, Sameer
    Baa, Annie K.
    CLINICAL NUCLEAR MEDICINE, 2021, 46 (12) : 994 - 995
  • [34] Clinical applications of long axial field-of-view PET/CT scanners in oncology
    Urso, Luca
    Frantellizzi, Viviana
    De Vincentis, Giuseppe
    Schillaci, Orazio
    Filippi, Luca
    Evangelista, Laura
    CLINICAL AND TRANSLATIONAL IMAGING, 2023, 11 (04) : 365 - 380
  • [35] Clinical applications of long axial field-of-view PET/CT scanners in oncology
    Luca Urso
    Viviana Frantellizzi
    Giuseppe De Vincentis
    Orazio Schillaci
    Luca Filippi
    Laura Evangelista
    Clinical and Translational Imaging, 2023, 11 : 365 - 380
  • [36] Long Axial Field-of-View PET/CT: New Opportunities for Pediatric Imaging
    Dias, Andre Henrique
    Andersen, Kim Francis
    Fosbol, Marie obro
    Gormsen, Lars Christian
    Andersen, Flemming Littrup
    Munk, Ole Lajord
    SEMINARS IN NUCLEAR MEDICINE, 2025, 55 (01) : 76 - 85
  • [37] The challenge of [18F]FDG PET/CT in the unexplored field of osteomyelitis
    Ferrari, C.
    Santo, G.
    Nappi, A. G.
    Merenda, N. C.
    Mammucci, P.
    Sciacqua, A.
    Pisani, A. R.
    Rubini, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S172 - S173
  • [38] [18F]FDG PET/CT outperforms [18F]FDG PET/MRI in differentiated thyroid cancer
    Vrachimis, Alexis
    Burg, Matthias Christian
    Wenning, Christian
    Allkemper, Thomas
    Weckesser, Matthias
    Schaefers, Michael
    Stegger, Lars
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (02) : 212 - 220
  • [39] [18F]FDG PET/CT outperforms [18F]FDG PET/MRI in differentiated thyroid cancer
    Alexis Vrachimis
    Matthias Christian Burg
    Christian Wenning
    Thomas Allkemper
    Matthias Weckesser
    Michael Schäfers
    Lars Stegger
    European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 212 - 220
  • [40] Ultra-low dose infection imaging of a newborn without sedation using long axial field-of-view PET/CT
    N. D. van Rijsewijk
    B. van Leer
    O. V. Ivashchenko
    E. H. Schölvinck
    F. van den Heuvel
    J. H. van Snick
    R. H. J. A. Slart
    W. Noordzij
    A. W. J. M. Glaudemans
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 622 - 623