Application of the long axial field-of-view PET/CT with low-dose [18F]FDG in melanoma

被引:36
|
作者
Sachpekidis, Christos [1 ]
Pan, Leyun [1 ]
Kopp-Schneider, Annette [2 ]
Weru, Vivienn [2 ]
Hassel, Jessica C. C. [3 ,4 ]
Dimitrakopoulou-Strauss, Antonia [1 ]
机构
[1] German Canc Res Ctr, Clin Cooperat Unit Nucl Med, Neuenheimer Feld 280, D-69210 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Biostat, Heidelberg, Germany
[3] Univ Hosp Heidelberg, Skin Canc Ctr, Dept Dermatol, Heidelberg, Germany
[4] Natl Ctr Tumor Dis Heidelberg, Heidelberg, Germany
关键词
Melanoma; LAFOV PET; F-18]FDG; Total body; Whole-body; SUV; FDG PET/CT; EQUIVALENCE; PROPORTIONS; TOMOGRAPHY; DIFFERENCE;
D O I
10.1007/s00259-022-06070-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AimThe recent introduction of long axial field-of-view (LAFOV) PET/CT scanners has yielded very promising results regarding image quality and sensitivity in oncological patients. We, herein, aim to determine an appropriate acquisition time range for the new long axial field of view Biograph Vision Quadra PET/CT (Siemens Healthcare) using low dose [F-18]FDG activity in a group of melanoma patients. MethodologyForty-nine melanoma patients were enrolled in the study. All patients underwent total body PET/CT from the top of the head through the feet in two bed positions (field-of-view 106 cm) after i.v. injection of 2.0 MBq/kg [F-18]FDG. The PET images of the first bed position (head to upper thigh; PET-10) were reconstructed and further split into 8-min (PET-8), 6-min (PET-6), 5-min (PET-5), 4-min (PET-4), and 2-min (PET-2) duration groups. Comparisons were performed between the different reconstructed scan times with regard to the visual evaluation of the PET/CT scans using the PET-10 images as reference and by calculating the 95%-CI for the differences between different time acquisitions. Moreover, objective evaluation of PET/CT image quality was performed based on SUV calculations of tumor lesions and background, leading to calculation of liver signal-to-noise ratio (SNR), and tumor-to-background ratio (TBR). ResultsA total of 60 scans were evaluated. Concerning visual analysis, 49/60 (81.7%) PET-10 scans were pathological, while the respective frequencies were 49/60 (81.7%) for PET-8 (95%-CI: - 0.0602-0.0602), 49/60 (81.7%) for PET-6 (95%-CI: - 0.0602-0.0602), 48/60 (80%) for PET-5 (95%-CI: - 0.0445-0.0886), 46/60 (76.7%) for PET-4 (95%-CI: - 0.0132-0.1370), and 45/60 (75%) for PET-2 (95%-CI: 0.0025-0.1593). In 18 PET-10 scans, the extent of metastatic involvement was very large, rendering the accurate calculation of [F-18]FDG-avid tumor lesions very complicated. In the remaining 42 PET-10 scans, for which the exact calculation of tumor lesions was feasible, a total of 119 tumor lesions were counted, and the respective lesion detection rates for shorter acquisitions were as follows: 97.5% (116/119) for PET-8 (95%-CI: 0-1), 95.0% (113/119) for PET-6 (95%-CI: 0-1), 89.9% (107/119) for PET-5 (95%-CI: 0-2), 83.2% (99/119) for PET-4 (95%-CI: 1-2), and 73.9% (88/119) for PET-2 (95%-CI: 2-4). With regard to objective image quality evaluations, as a general trend, the reduction of acquisition time was associated with a decrease of liver SNR and a decrease of TBR, although in lesion-based analysis the change in TBR and tumor SUVmean values was non-significant up to 6 and 5 min acquisitions, respectively. ConclusionsIn melanoma, low-dose LAFOV PET/CT imaging is feasible and can reduce the total scan time from head to upper thigh up to 5 min providing comparable diagnostic data to standard lengths of acquisition. This may have significant implications for the diagnostic work-up of patients with melanoma, given the need for true whole-body imaging in this type of cancer.
引用
收藏
页码:1158 / 1167
页数:10
相关论文
共 50 条
  • [21] Initial experience with 18F FDG PET/CT in Anorectal Melanoma
    Rangarajan, V.
    Purandare, N. C.
    Arora, A.
    Shah, S.
    Sharma, A. R.
    Parasar, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S274 - S274
  • [22] Expert consensus on workflow of PET/CT with long axial field-of-view
    Liu, Guobing
    Gu, Yushen
    Sollini, Martina
    Lazar, Alexandra
    Besson, Florent L.
    Li, Sijin
    Wu, Zhifang
    Nardo, Lorenzo
    Al-Ibraheem, Akram
    Zheng, Jiefu
    Kulkarni, Harshad R.
    Rominger, Axel
    Fan, Wei
    Zhu, Xiaohua
    Zhao, Xinming
    Wu, Hubing
    Liu, Jianjun
    Li, Biao
    Cheng, Zhaoping
    Wang, Ruimin
    Xu, Baixuan
    Agostini, Denis
    Tang, Han
    Tan, Lijie
    Yang, Zhi
    Huo, Li
    Gu, Jianying
    Shi, Hongcheng
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025, 52 (03) : 1038 - 1049
  • [23] Long Axial Field-of-View (LAFOV) PET/CT in Prostate Cancer
    Sachpekidis, Christos
    Dimitrakopoulou-Strauss, Antonia
    SEMINARS IN NUCLEAR MEDICINE, 2025, 55 (01) : 67 - 75
  • [24] Clinical experience of 18F-FDG-PET/CT performed with the low-dose injection of 18F-FDG
    Jinguji, M.
    Nakajo, M.
    Tani, A.
    Nagano, H.
    Matsumoto, T.
    Fujisaka, T.
    Yoshiura, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S709 - S709
  • [25] Robustness of radiomic features in [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Vuong, D.
    Bogowicz, M.
    Huellner, M.
    Veit-Haibach, P.
    Andratschke, N.
    Unkelbach, J.
    Guckenberger, M.
    Tanadini-Lang, S.
    JOURNAL OF THORACIC ONCOLOGY, 2018, 13 (04) : S41 - S41
  • [26] Application of the long axial field-of-view PET/CT with direct and indirect Patlak parametric imaging
    Pan, L.
    Sachpekidis, C.
    Dimitrakopoulou-Strauss, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S258 - S258
  • [27] Validating image-derived input functions in dynamic 18F-FDG PET scans acquired on a long-axial field-of-view PET/CT system
    Smith, Charlotte
    Yaqub, Maqsood
    Zwezerijnen, Gerben
    den Hollander, Marijke
    Zijlstra, Josee
    van Oordt, Catharina Menke-van der Houven
    Bahce, Idris
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [28] Long axial field of view PET enables ultra-low-dose PET/CT
    Krarup, M.
    d'Este, S. Honore
    Rexhepi, L.
    Andersen, F. Littrup
    Hojgaard, L.
    Fischer, B. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S76 - S76
  • [29] A low-dose protocol in pediatric 18F-FDG scans using 30-cm axis field of view PET/CT
    Wu, Ha
    Liu, Guobing
    Ruan, Xiemei
    Zhang, Biying
    Zhe, Zheng
    Shi, Hongcheng
    ANNALS OF NUCLEAR MEDICINE, 2025,
  • [30] Staging with [18F]FDG PET/CT
    Iqbal, Ramsha
    Aras, Tuba
    Mammatas, Lemonitsa
    Vogel, Wouter V.
    Oprea-Lager, Daniela E.
    Verheul, Hendrik M.
    Boellaard, Ronald
    van Oordt, Catharina W. Menke-van der Houven
    CANCER RESEARCH, 2019, 79 (13)