Application of the long axial field-of-view PET/CT with low-dose [18F]FDG in melanoma

被引:36
|
作者
Sachpekidis, Christos [1 ]
Pan, Leyun [1 ]
Kopp-Schneider, Annette [2 ]
Weru, Vivienn [2 ]
Hassel, Jessica C. C. [3 ,4 ]
Dimitrakopoulou-Strauss, Antonia [1 ]
机构
[1] German Canc Res Ctr, Clin Cooperat Unit Nucl Med, Neuenheimer Feld 280, D-69210 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Biostat, Heidelberg, Germany
[3] Univ Hosp Heidelberg, Skin Canc Ctr, Dept Dermatol, Heidelberg, Germany
[4] Natl Ctr Tumor Dis Heidelberg, Heidelberg, Germany
关键词
Melanoma; LAFOV PET; F-18]FDG; Total body; Whole-body; SUV; FDG PET/CT; EQUIVALENCE; PROPORTIONS; TOMOGRAPHY; DIFFERENCE;
D O I
10.1007/s00259-022-06070-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AimThe recent introduction of long axial field-of-view (LAFOV) PET/CT scanners has yielded very promising results regarding image quality and sensitivity in oncological patients. We, herein, aim to determine an appropriate acquisition time range for the new long axial field of view Biograph Vision Quadra PET/CT (Siemens Healthcare) using low dose [F-18]FDG activity in a group of melanoma patients. MethodologyForty-nine melanoma patients were enrolled in the study. All patients underwent total body PET/CT from the top of the head through the feet in two bed positions (field-of-view 106 cm) after i.v. injection of 2.0 MBq/kg [F-18]FDG. The PET images of the first bed position (head to upper thigh; PET-10) were reconstructed and further split into 8-min (PET-8), 6-min (PET-6), 5-min (PET-5), 4-min (PET-4), and 2-min (PET-2) duration groups. Comparisons were performed between the different reconstructed scan times with regard to the visual evaluation of the PET/CT scans using the PET-10 images as reference and by calculating the 95%-CI for the differences between different time acquisitions. Moreover, objective evaluation of PET/CT image quality was performed based on SUV calculations of tumor lesions and background, leading to calculation of liver signal-to-noise ratio (SNR), and tumor-to-background ratio (TBR). ResultsA total of 60 scans were evaluated. Concerning visual analysis, 49/60 (81.7%) PET-10 scans were pathological, while the respective frequencies were 49/60 (81.7%) for PET-8 (95%-CI: - 0.0602-0.0602), 49/60 (81.7%) for PET-6 (95%-CI: - 0.0602-0.0602), 48/60 (80%) for PET-5 (95%-CI: - 0.0445-0.0886), 46/60 (76.7%) for PET-4 (95%-CI: - 0.0132-0.1370), and 45/60 (75%) for PET-2 (95%-CI: 0.0025-0.1593). In 18 PET-10 scans, the extent of metastatic involvement was very large, rendering the accurate calculation of [F-18]FDG-avid tumor lesions very complicated. In the remaining 42 PET-10 scans, for which the exact calculation of tumor lesions was feasible, a total of 119 tumor lesions were counted, and the respective lesion detection rates for shorter acquisitions were as follows: 97.5% (116/119) for PET-8 (95%-CI: 0-1), 95.0% (113/119) for PET-6 (95%-CI: 0-1), 89.9% (107/119) for PET-5 (95%-CI: 0-2), 83.2% (99/119) for PET-4 (95%-CI: 1-2), and 73.9% (88/119) for PET-2 (95%-CI: 2-4). With regard to objective image quality evaluations, as a general trend, the reduction of acquisition time was associated with a decrease of liver SNR and a decrease of TBR, although in lesion-based analysis the change in TBR and tumor SUVmean values was non-significant up to 6 and 5 min acquisitions, respectively. ConclusionsIn melanoma, low-dose LAFOV PET/CT imaging is feasible and can reduce the total scan time from head to upper thigh up to 5 min providing comparable diagnostic data to standard lengths of acquisition. This may have significant implications for the diagnostic work-up of patients with melanoma, given the need for true whole-body imaging in this type of cancer.
引用
收藏
页码:1158 / 1167
页数:10
相关论文
共 50 条
  • [1] Application of the long axial field-of-view PET/CT with low-dose [18F]FDG in melanoma
    Christos Sachpekidis
    Leyun Pan
    Annette Kopp-Schneider
    Vivienn Weru
    Jessica C. Hassel
    Antonia Dimitrakopoulou-Strauss
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 1158 - 1167
  • [2] Image Quality and Quantitative PET Parameters of Low-Dose [18F]FDG PET in a Long Axial Field-of-View PET/CT Scanner
    Calderon, Eduardo
    Schmidt, Fabian P.
    Lan, Wenhong
    Castaneda-Vega, Salvador
    Brendlin, Andreas S.
    Trautwein, Nils F.
    Dittmann, Helmut
    la Fougere, Christian
    Kiefer, Lena Sophie
    DIAGNOSTICS, 2023, 13 (20)
  • [3] Application of the long axial field-of-view PET/CT in metastatic melanoma patients studied with 18F-FDG
    Sachpekidis, C.
    Pan, L.
    Hassel, J. C.
    Dimitrakopoulou-Strauss, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S231 - S231
  • [4] Lesion conspicuity by size in [18F]FDG long-axial field-of-view PET/CT
    Mingels, C.
    Weissenrieder, L.
    Zeimpekis, K.
    Sari, H.
    Seifert, R.
    Caobelli, F.
    Nardo, L.
    Rominger, A.
    Pyka, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S703 - S703
  • [5] -Paediatric Dose Optimization for Long Axial Field-of-View FDG PET/CT
    van der Kaap, D.
    Deuten, M.
    van Snick, P. J. H.
    Noordzij, W.
    Slart, R. H. J. A.
    Brouwers, A. H.
    Glaudemans, A. W. J. M.
    Koopmans, K. P.
    Ivashchenko, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S310 - S311
  • [6] Long axial field-of-view PET imaging of intraarterial 2-[18F]FDG injection
    Krieger, Korbinian
    Bregenzer, Carola Maria
    Weissenrieder, Luis
    Rominger, Axel
    Pyka, Thomas
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025, 52 (03) : 1228 - 1229
  • [7] Patlak parametric analysis of low-dose 18F-FDG study in uMI Panorama GS, a new long axial field-of-view PET/CT system
    Ye, Qing
    Zhao, Yizhang
    Zeng, Hao
    Shi, Lei
    Zhu, Yuchun
    Huo, Li
    Lu, Yihuan
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [8] Low-activity [18F]-somatostatin receptor (SSTR) imaging using [18F]SiTATE on a long axial field-of-view PET/CT scanner
    Trautwein, Nils F.
    Calderon, Eduardo
    Linder, Pia M.
    Reischl, Gerald
    Driessen, Philippe
    Lan, Wenhong
    Brendlin, Andreas S.
    Gross, Thorben
    Dittmann, Helmut
    Hinterleitner, Martina
    la Fougere, Christian
    Schmidt, Fabian P.
    Kiefer, Lena S.
    EJNMMI PHYSICS, 2025, 12 (01):
  • [9] Ultra-low foetal radiation exposure in 18F-FDG PET/CT imaging with a long axial field-of-view PET/CT system
    Smith, Charlotte L. C.
    Yaqub, Maqsood
    Wellenberg, Ruud H. H.
    Knip, Jelijn J.
    Boellaard, Ronald
    Zwezerijnen, Gerben J. C.
    EJNMMI PHYSICS, 2024, 11 (01):
  • [10] Influence of the number of iterations on image quality and semiquantitative accuracy in [18F]FDG PET imaging using a Long Axial Field-of-View PET/CT system
    van der Vegt, M.
    Dierckx, R. A. J. O.
    Glaudemans, A. W. J. M.
    van Sluis, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S149 - S149