Phantom-based evaluation of yttrium-90 datasets using biograph vision quadra

被引:5
|
作者
Zeimpekis, Konstantinos G. [1 ]
Mercolli, Lorenzo [1 ]
Conti, Maurizio [2 ]
Sari, Hasan [3 ]
Prenosil, George [1 ]
Shi, Kuangyu [1 ]
Rominger, Axel [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Nucl Med, Inselspital, Bern, Switzerland
[2] Siemens Healthineers, Mol Imaging, Knoxville, TN USA
[3] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
关键词
Whole-body PET; CT; Yttrium-90; NEMA; Image quality; Quadra; RADIOEMBOLIZATION; DOSIMETRY; PET/CT; PERFORMANCE; QUALITY;
D O I
10.1007/s00259-022-06074-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The image quality characteristics of two NEMA phantoms with yttrium-90 (Y-90) were evaluated on a long axial field-of-view (AFOV) PET/CT. The purpose was to identify the optimized reconstruction setup for the imaging of patients with hepatocellular carcinoma after Y-90 radioembolization.Methods:Two NEMA phantoms were used, where one had a 1:10 sphere to background activity concentration ratio and the second had cold background. Reconstruction parameters used are as follows: iterations 2 to 8, Gaussian filter 2- to 6-mm full-width-at-half-maximum, reconstruction matrices 440 x 440 and 220 x 220, high sensitivity (HS), and ultra-high sensitivity (UHS) modes. 50-, 40-, 30-, 20-, 10-, and 5-min acquisitions were reconstructed. The measurements included recovery coefficients (RC), signal-to-noise ratio (SNR), background variability, and lung error which measures the residual error in the corrections. Patient data were reconstructed with 20-, 10-, 5-, and 1-min time frames and evaluated in terms of SNR.Results: The RC for the hot phantom was 0.36, 0.45, 0.53, 0.63, 0.68, and 0.84 for the spheres with diameters of 10, 13, 17, 22, 28, and 37 mm, respectively, for UHS 2 iterations, a 220 x 220 matrix, and 50-min acquisition. The RC values did not differ with acquisition times down to 20 min. The SNR was the highest for 2 iterations, measured 11.7, 16.6, 17.6, 19.4, 21.9, and 27.7 while the background variability was the lowest (27.59, 27.08, 27.36, 26.44, 30.11, and 33.51%). The lung error was 18%. For the patient dataset, the SNR was 19%, 20%, 24%, and 31% higher for 2 iterations compared to 4 iterations for 20-, 10-, 5-, and 1-min time frames, respectively.Conclusions: This study evaluates the NEMA image quality of a long AFOV PET/CT scanner with Y-90. It provides high RC for the smallest sphere compared to other standard AFOV scanners at shorter scan times. The maximum patient SNR was for 2 iterations, 20 min, while 5 min delivers images with acceptable SNR.
引用
收藏
页码:1168 / 1182
页数:15
相关论文
共 50 条
  • [31] Role of FDG-PET in Yttrium-90 treatment response evaluation
    Seraj, Siavash Mehdizadeh
    Jahangiri, Pegah
    Zadeh, Mahdi Zirakchian
    Al-zaghal, Abdullah
    Werner, Thomas
    Zhuang, Hongming
    Alavi, Abass
    Hunt, Stephen
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [32] Urinary Excretion of Yttrium-90 after Radioembolization with Yttrium-90-Labeled Resin-based Microspheres
    Grosser, Oliver S.
    Ruf, Juri
    Pethe, Annette
    Kupitz, Dennis
    Wissel, Heiko
    Benckert, Christoph
    Pech, Maciej
    Ricke, Jens
    Amthauer, Holger
    HEALTH PHYSICS, 2018, 114 (01): : 58 - 63
  • [33] Phantom and clinical evaluation of the effect of full Monte Carlo collimator modelling in post-SIRT yttrium-90 Bremsstrahlung SPECT imaging
    Porter, Charlotte A.
    Bradley, Kevin M.
    Hippelainen, Eero T.
    Walker, Matthew D.
    McGowan, Daniel R.
    EJNMMI RESEARCH, 2018, 8
  • [34] Impact of acquisition time on image quality and visibility of Yttrium-90 Positron Emission Tomography: A phantom study
    Thareeboonchai, T.
    Buranatrivedhaya, N.
    Sriwiang, W.
    Charoenphun, P.
    Chuamsaamarkkee, K.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [35] Hepatopulmonary Shunt Reduction Using Chemoembolization to Permit Yttrium-90 Radioembolization
    Rose, Steven C.
    Hoh, Carl K.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (06) : 849 - 851
  • [36] Phantom and clinical evaluation of the effect of full Monte Carlo collimator modelling in post-SIRT yttrium-90 Bremsstrahlung SPECT imaging
    Charlotte A. Porter
    Kevin M. Bradley
    Eero T. Hippeläinen
    Matthew D. Walker
    Daniel R. McGowan
    EJNMMI Research, 8
  • [37] Study of yttrium-90 radiation attenuation using different types of shielding
    Rey Sanchez, L.
    Franco Monterroso, C. G.
    Santos Montero, B.
    Pascual Pascual, V.
    Garcia Lama, L.
    Hernandez Fructuoso, M. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S736 - S736
  • [38] Quantitative Evaluation of PET/CT and SPECT/CT-based Dosimetry following Yttrium-90 Radioembolization
    Kappadath, S.
    Henry, C.
    Lopez, B.
    Mahvash, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S424 - S425
  • [39] Multi-institutional phantom study of yttrium-90 PET-based dosimetry of hepatic radioembolization using PET/MRI: The MR-QUEST Study
    Maughan, Nichole
    Eldib, Mootaz
    Faul, David
    Laforest, Richard
    Conti, Maurizio
    Elschot, Mattijs
    Knesaurek, Karin
    Leek, Francesca
    Townsend, David
    DiFilippo, Frank
    Jackson, Kimberly
    Tapner, Michael
    Parikh, Parag
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [40] Quantification accuracy evaluation of Yttrium-90 PET for post-therapeutic voxelised dosimetry on three generations PET/CT scanners: a phantom study
    Croes, G.
    van Sluis, J.
    Willemsen, A.
    Noordzij, W.
    Ivashchenko, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S361 - S361