Mucosal Impedance Spectroscopy for Objective Real-time Assessment of Mucosal Health

被引:1
|
作者
Arora, Priyanka [1 ]
Singh, Jaspreet [2 ]
Jena, Anuraag [1 ]
Kumar, Surinder [1 ]
Sardana, Viren [3 ]
Sarkar, Siddhartha [3 ]
Kaman, Lileswar [4 ]
Behera, Arunanshu [4 ]
Dahiya, Divya [4 ]
Nada, Ritambhra [5 ]
Tandup, Cherring [4 ]
Jatana, H. S. [2 ]
Dutta, Usha [1 ,6 ]
机构
[1] Post Grad Inst Med Educ & Res, Dept Gastroenterol, Chandigarh, India
[2] Dept MEMS, Semicond Lab, Mohali, India
[3] Cent Sci Instrument Org, Chandigarh, India
[4] Post Grad Inst Med Educ & Res, Dept Surg, Chandigarh, India
[5] Post Grad Inst Med Educ & Res, Dept Histopathol, Chandigarh, India
[6] Postgrad Inst Med Educ & Res, Dept Gastroenterol, Chandigarh 160012, India
关键词
Impedance; Malignancy; Inflammation; Endoscopic catheter; TIGHT JUNCTION PROTEINS; DIAGNOSIS;
D O I
10.1016/j.tige.2023.03.007
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND AND AIMS: There is a need for a real-time objective tool to assess the mucosal health of the gastrointestinal (GI) tract during endoscopy. Our aim was to develop, design, and validate a lowcost mucosal impedance (MI) device and determine its role in differentiating diseased mucosa from normal mucosa. METHODS: A biocompatible catheter was designed and developed after multiple iterations. It was validated with a commercially available catheter and histopathological analysis in a blinded manner. Patients undergoing resection of the GI tract were recruited after consent, and the resected specimens were analyzed ex vivo for MI within 10 minutes of resection. An average of 3 MI readings of the visually diseased segment and adjacent normal segment were analyzed. MI values of diseased and non-diseased mucosa were compared. RESULTS: The in-house catheter was validated with a commercially available impedance measuring device. It showed a high degree of positive correlation (rho = 0.616; P < 0.001). Two hundred and thirtytwo patients (age 46 </n> 15 years; 68% females) (180 inflammatory and 52 malignant pathology) who were undergoing abdominal surgery were enrolled. The median impedance value of diseased segments was significantly lower than that of the adjacent normal segments of gut in 130 paired samples [1832 (727)Q vs 2604(1295)Q; P < 0.001]. The MI value of segments containing malignant tissue (n = 50) and inflamed tissue (n = 80) was significantly lower than the MI value of adjacent normal segments of the GI tract [1880(977)Q vs 2583(1431)Q; P < 0.001 and 1787(557)Q vs 2515(1244)Q; P < 0.001, respectively]. There was a 24% reduction in visually diseased segments [median reduction 712(661)Q] from adjacent normal segments. A biocompatible endoscopic catheter (3-mm diameter) has been developed and tested in 3 patients and was found to differentiate diseased from normal mucosa. CONCLUSION: Impedance spectroscopy is an effective real-time, simple, objective tool to differentiate diseased gut mucosa from healthy mucosa.
引用
收藏
页码:228 / 235
页数:8
相关论文
共 50 条
  • [1] ENDOSCOPIC MUCOSAL IMPEDANCE SPECTROSCOPY: FOR OBJECTIVE REAL TIME ASSESSMENT OF MUCOSAL HEALTH
    Arora, Priyanka P.
    Singh, Jaspreet
    Jena, Anuraag
    Kumar, Surinder
    Sardana, Viren
    Sarkar, Siddhartha
    Kaman, Lileshwar
    Behra, Arunanshu
    Dahiya, Divya
    Nada, Ritambhra
    Tandup, Cherring
    Jattana, H. S.
    Dutta, Usha
    GASTROENTEROLOGY, 2023, 164 (06) : S490 - S491
  • [2] Endocytoscopy for in situ real-time histology of oral mucosal lesions
    Miyamoto, I.
    Yada, N.
    Osawa, K.
    Yoshioka, I.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 47 (07) : 896 - 899
  • [3] REAL-TIME ENDOSCOPIC MUCOSAL OXYGEN SATURATION MEASUREMENT: TECHNICAL FEASIBILITY AND MARGINAL ULCER ASSESSMENT
    Szvarca, Daniel
    Walradt, Trent
    Thompson, Christopher
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB758 - AB759
  • [4] Real-Time Measurement of Rectal Mucosal Microcirculation During Cardiopulmonary Bypass
    Kiessling, Arndt-H.
    Reyher, Christian
    Philipp, Michael
    Beiras-Fernandez, Andres
    Moritz, Anton
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (01) : 89 - 94
  • [5] Real-Time Endoscopy-Guided Measurement of Mucosal Admittance to Diagnose Mucosal Integrity in Patients With Gastroesophageal Reflux Disease
    Matsumura, Tomoaki
    Arai, Makoto
    Mai Fujie
    Ishigami, Hideaki
    Okimoto, Kenichiro
    Maruoka, Daisuke
    Nakagawa, Tomoo
    Yokosuka, Osamu
    GASTROENTEROLOGY, 2016, 150 (04) : S278 - S278
  • [6] Potential of Impedance Spectroscopy for Real-Time Assessing of Food Quality
    Guermazi, Mahdi
    Fendri, Ahmed
    Kanoun, Olfa
    Derbel, Nabil
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2018, 21 (06) : 44 - 48
  • [7] Graphene Microelectrodes for Real-Time Impedance Spectroscopy of Neural Cells
    Niaraki, Amir
    McNamara, Marilyn C.
    Montazami, Reza
    Hashemi, Nicole N.
    ACS APPLIED BIO MATERIALS, 2022, 5 (01) : 113 - 122
  • [8] Real-time monitoring of amyloid fibrillation by electrical impedance spectroscopy
    da Silva, Rafael R.
    de Lima, Sandro V.
    de Oliveira, Helinando P.
    de Melo, Celso P.
    Frias, Isaac A. M.
    Oliveira, Maria D. L.
    Andrade, Cesar A. S.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2017, 160 : 724 - 731
  • [9] Real-Time Analysis of Mucosal Flora in Patients with Inflammatory Bowel Disease in India
    Verma, Ravi
    Verma, Anil Kumar
    Ahuja, Vineet
    Paul, Jaishree
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (11) : 4279 - 4282
  • [10] Objective real-time assessment of walking and turning in elderly adults
    Skrba, Zoran
    O'Mullane, Brian
    Greene, Barry R.
    Scanaill, Cliodhna Ni
    Fan, Chie Wei
    Quigley, Aaron
    Nixon, Paddy
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 807 - +