Mucosal Impedance Spectroscopy for Objective Real-time Assessment of Mucosal Health

被引:1
|
作者
Arora, Priyanka [1 ]
Singh, Jaspreet [2 ]
Jena, Anuraag [1 ]
Kumar, Surinder [1 ]
Sardana, Viren [3 ]
Sarkar, Siddhartha [3 ]
Kaman, Lileswar [4 ]
Behera, Arunanshu [4 ]
Dahiya, Divya [4 ]
Nada, Ritambhra [5 ]
Tandup, Cherring [4 ]
Jatana, H. S. [2 ]
Dutta, Usha [1 ,6 ]
机构
[1] Post Grad Inst Med Educ & Res, Dept Gastroenterol, Chandigarh, India
[2] Dept MEMS, Semicond Lab, Mohali, India
[3] Cent Sci Instrument Org, Chandigarh, India
[4] Post Grad Inst Med Educ & Res, Dept Surg, Chandigarh, India
[5] Post Grad Inst Med Educ & Res, Dept Histopathol, Chandigarh, India
[6] Postgrad Inst Med Educ & Res, Dept Gastroenterol, Chandigarh 160012, India
关键词
Impedance; Malignancy; Inflammation; Endoscopic catheter; TIGHT JUNCTION PROTEINS; DIAGNOSIS;
D O I
10.1016/j.tige.2023.03.007
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND AND AIMS: There is a need for a real-time objective tool to assess the mucosal health of the gastrointestinal (GI) tract during endoscopy. Our aim was to develop, design, and validate a lowcost mucosal impedance (MI) device and determine its role in differentiating diseased mucosa from normal mucosa. METHODS: A biocompatible catheter was designed and developed after multiple iterations. It was validated with a commercially available catheter and histopathological analysis in a blinded manner. Patients undergoing resection of the GI tract were recruited after consent, and the resected specimens were analyzed ex vivo for MI within 10 minutes of resection. An average of 3 MI readings of the visually diseased segment and adjacent normal segment were analyzed. MI values of diseased and non-diseased mucosa were compared. RESULTS: The in-house catheter was validated with a commercially available impedance measuring device. It showed a high degree of positive correlation (rho = 0.616; P < 0.001). Two hundred and thirtytwo patients (age 46 </n> 15 years; 68% females) (180 inflammatory and 52 malignant pathology) who were undergoing abdominal surgery were enrolled. The median impedance value of diseased segments was significantly lower than that of the adjacent normal segments of gut in 130 paired samples [1832 (727)Q vs 2604(1295)Q; P < 0.001]. The MI value of segments containing malignant tissue (n = 50) and inflamed tissue (n = 80) was significantly lower than the MI value of adjacent normal segments of the GI tract [1880(977)Q vs 2583(1431)Q; P < 0.001 and 1787(557)Q vs 2515(1244)Q; P < 0.001, respectively]. There was a 24% reduction in visually diseased segments [median reduction 712(661)Q] from adjacent normal segments. A biocompatible endoscopic catheter (3-mm diameter) has been developed and tested in 3 patients and was found to differentiate diseased from normal mucosa. CONCLUSION: Impedance spectroscopy is an effective real-time, simple, objective tool to differentiate diseased gut mucosa from healthy mucosa.
引用
收藏
页码:228 / 235
页数:8
相关论文
共 50 条
  • [31] Esophageal Mucosal Impedance: Is It Time to Forgo Prolonged Gastroesophageal Reflux Recordings?
    Fass, Ronnie
    GASTROENTEROLOGY, 2015, 148 (02) : 282 - 285
  • [32] Development of modified laser Doppler flowmetry device for real-time monitoring of esophageal mucosal blood flow: a preclinical assessment with an animal model
    Kawarai, Shun-Ichi
    Katahira, Shintaro
    Miyatake, Midori
    Itagaki, Kota
    Tsuruoka, Noriko
    Haga, Yoichi
    Saiki, Yoshikatsu
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (03) : 284 - 292
  • [33] Assessment of oral mucosal lesions with autofluorescence imaging and reflectance spectroscopy
    Lalla, Yastira
    Matias, Marie Anne T.
    Farah, Camile S.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2016, 147 (08): : 650 - 660
  • [34] In Vivo Molecular Imaging and Real Time Assessment of Gastric Mucosal Injury and Protection Using Confocal Laser Endomicroscopy: Focus on Mucosal Microvessels and Progenitor Cells
    Tarnawski, A. S.
    Ahluwalia, A.
    Jones, M. K.
    Gergely, H. M.
    DIGESTIVE DISEASES AND SCIENCES, 2014, 59 (08) : 1665 - 1666
  • [35] REAL-TIME FOURIER SPECTROSCOPY
    HOFFMAN, JE
    APPLIED OPTICS, 1969, 8 (02): : 323 - &
  • [36] Femtosecond real-time spectroscopy
    Schreiber, E
    FEMTOSECOND REAL-TIME SPECTROSCOPY OF SMALL MOLECULES AND CLUSTERS, 1998, 143 : 9 - 48
  • [37] In-Situ Assessment of Array Antenna Currents for Real-Time Impedance Tuning
    Baylis, Charles
    Goad, Adam
    Van Hoosier, Trevor
    Egbert, Austin
    Marks, Robert J., II
    2022 IEEE INTERNATIONAL SYMPOSIUM ON PHASED ARRAY SYSTEMS & TECHNOLOGY (PAST), 2022,
  • [38] Integration of the fluorescence based portable device with the AI tools for the real-time monitoring of oral mucosal lesions
    Kumar, Pavan
    Rathod, Shashikant
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [39] Real-Time Impedance-Based Stability Assessment of Grid Converter Interactions
    Messo, Tuomas
    Luhtala, Roni
    Roinila, Tomi
    Yang, Dongsheng
    Wang, Xiongfei
    Blaabjerg, Frede
    2017 IEEE 18TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2017,
  • [40] Detection of herpes simplex virus infection in mucosal and cutaneous ulcers of the suspected patients by real-time PCR
    Ziyaeyan, M.
    Namayandeh, M.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2012, 16 : E120 - E121