Circular External Fixator Assisted Open Reduction Combined With Locking Plate Fixation for Intra-articular Comminuted Fractures of the Calcaneus

被引:2
|
作者
Hou, Jiguang [1 ]
Zhang, Nan [2 ]
Chen, Guodong [1 ]
Wang, Qi [1 ]
Zhang, Shenghua [1 ]
Yang, Kun [1 ]
Zang, Hongwei [1 ]
机构
[1] First Hosp Qinhuangdao, Dept Orthpaed, Qinhuangdao, Hebei, Peoples R China
[2] First Hosp Qinhuangdao, Dept Anesthesiol, Qinhuangdao, Hebei, Peoples R China
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2023年 / 62卷 / 03期
关键词
auxiliary reduction; annular external fixator; extended lateral approach traction; 3-dimensional adjustment; INTERNAL-FIXATION; PERCUTANEOUS FIXATION; OPERATIVE TREATMENT; SURGICAL-TREATMENT; COMPLICATIONS;
D O I
10.1053/j.jfas.2022.10.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Comminuted fractures of the calcaneus are relatively common and generally require surgical treatment. The quality of fracture reduction is crucial. The extended lateral approach (ELA) can better expose the fracture end and facilitate the reduction of the fracture, while it has a higher risk of postoperative skin complications. In this study, the ELA was adopted, and the calcaneal comminuted fractures were treated with circular external fixator assisted reduction to achieve the purpose of good reduction of the fracture and fewer skin complications. During 64 months, a total of 61 cases of unilateral calcaneal fractures were treated by the same surgeon and followed up for 19.28 +/- 5.28 months. During the operation, a circular external fixator was employed to fix the midfoot and the distal end of the tibia, and the calcaneal tubercle; then, the calcaneal tubercle was distracted to restore the 3-dimensional structure of the calcaneus. The ELA was utilized to reduce the articular surface fracture. The fracture was fixated with a locking plate. Postoperative radiographs were regularly reviewed. Meanwhile, Boeurohler's angle and Gissane's angle were measured. Visual analogue scale and American Orthopedic Foot and Ankle Society Score assessments were performed at the final follow-up. All fractures healed. The mean preoperative Boeurohler's angle was 9.3 +/- 10.1 degrees; the mean Gissane's angle was 110.5 +/- 14.7 degrees; the immediate postoperative mean Boeurohler's angle was 31.3 +/- 5.5 degrees; mean Gissane's angle was 110.9 +/- 5.9 degrees. Local superficial necrosis of surgical incision occurred in 2 cases, which healed well after dressing changes. Skin necrosis appeared in 1 case, where debridement and local flap transfer were performed. At the final follow-up, the mean visual analogue scale score was 1.48 +/- 1.30, and the mean American Orthopedic Foot and Ankle Society Score was 90.16 +/- 7.19. The ELA combined with a circular external fixator to assist in the reduction of calcaneal fractures achieved good reduction quality and effectively reduced postoperative complications. (c) 2022 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:437 / 443
页数:7
相关论文
共 50 条
  • [41] External fixation for displaced intra-articular fractures of the calcaneum
    Magnan, B.
    Bortolazzi, R.
    Marangon, A.
    Marino, M.
    Dall'Oca, C.
    Bartolozzi, P.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (11): : 1474 - 1479
  • [42] Intra-articular fractures of the distal aspect of the radius: Arthroscopically assisted reduction compared with open reduction and internal fixation
    Doi, K
    Hattori, Y
    Otsuka, K
    Abe, Y
    Yamamoto, H
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (08): : 1093 - 1110
  • [43] Limited open reduction and internal fixation of displaced intra-articular fractures of the calcaneum
    Weber, M.
    Lehmann, O.
    Saegesser, D.
    Krause, F.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (12): : 1608 - 1616
  • [44] A Randomized Comparison of Volar Plate and External Fixation for Intra-Articular Distal Radius Fractures
    Roh, Young Hak
    Lee, Beom Koo
    Baek, Jong Ryoon
    Noh, Jung Ho
    Gong, Hyun Sik
    Baek, Goo Hyun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01): : 34 - 41
  • [45] Early Results of A Simple Distraction Dynamic External Fixator in Management of Comminuted Intra-Articular Fractures of Base of Middle Phalanx
    Mansha, Muhammad
    Miranda, Sanjay
    JOURNAL OF HAND AND MICROSURGERY, 2013, 5 (02) : 63 - 67
  • [46] Follow-up evaluation of open intra-articular fractures of the calcaneus
    C. H. Siebert
    M. Hansen
    D. Wolter
    Archives of Orthopaedic and Trauma Surgery, 1998, 117 : 442 - 447
  • [47] Management of Complex Intra-Articular Distal Radius Fractures with Open Reduction and Internal Fixation with Double Dorsal Locking Plates
    Herdrich, S.
    Bauer, J.
    Pichl, J.
    Hoffmann, R.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (01): : 72 - 79
  • [48] Follow-up evaluation of open intra-articular fractures of the calcaneus
    Siebert, CH
    Hansen, M
    Wolter, D
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1998, 117 (08) : 442 - 447
  • [49] Clinical effect of closed reduction minimally invasive fixation in intra-articular comminuted fractures of the femoral condyle
    Lian, Xiaodong
    Zhang, Heng
    Guo, Fan
    Wang, Zhongzheng
    Zhao, Kuo
    Hou, Zhiyong
    Zhang, Yingze
    FRONTIERS IN SURGERY, 2023, 10
  • [50] Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures
    Han, L. R.
    Jin, C. X.
    Yan, J.
    Han, S. Z.
    He, X. B.
    Yang, X. F.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (01) : 2912 - 2919