Circular External Fixator Assisted Open Reduction Combined With Locking Plate Fixation for Intra-articular Comminuted Fractures of the Calcaneus

被引:2
|
作者
Hou, Jiguang [1 ]
Zhang, Nan [2 ]
Chen, Guodong [1 ]
Wang, Qi [1 ]
Zhang, Shenghua [1 ]
Yang, Kun [1 ]
Zang, Hongwei [1 ]
机构
[1] First Hosp Qinhuangdao, Dept Orthpaed, Qinhuangdao, Hebei, Peoples R China
[2] First Hosp Qinhuangdao, Dept Anesthesiol, Qinhuangdao, Hebei, Peoples R China
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2023年 / 62卷 / 03期
关键词
auxiliary reduction; annular external fixator; extended lateral approach traction; 3-dimensional adjustment; INTERNAL-FIXATION; PERCUTANEOUS FIXATION; OPERATIVE TREATMENT; SURGICAL-TREATMENT; COMPLICATIONS;
D O I
10.1053/j.jfas.2022.10.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Comminuted fractures of the calcaneus are relatively common and generally require surgical treatment. The quality of fracture reduction is crucial. The extended lateral approach (ELA) can better expose the fracture end and facilitate the reduction of the fracture, while it has a higher risk of postoperative skin complications. In this study, the ELA was adopted, and the calcaneal comminuted fractures were treated with circular external fixator assisted reduction to achieve the purpose of good reduction of the fracture and fewer skin complications. During 64 months, a total of 61 cases of unilateral calcaneal fractures were treated by the same surgeon and followed up for 19.28 +/- 5.28 months. During the operation, a circular external fixator was employed to fix the midfoot and the distal end of the tibia, and the calcaneal tubercle; then, the calcaneal tubercle was distracted to restore the 3-dimensional structure of the calcaneus. The ELA was utilized to reduce the articular surface fracture. The fracture was fixated with a locking plate. Postoperative radiographs were regularly reviewed. Meanwhile, Boeurohler's angle and Gissane's angle were measured. Visual analogue scale and American Orthopedic Foot and Ankle Society Score assessments were performed at the final follow-up. All fractures healed. The mean preoperative Boeurohler's angle was 9.3 +/- 10.1 degrees; the mean Gissane's angle was 110.5 +/- 14.7 degrees; the immediate postoperative mean Boeurohler's angle was 31.3 +/- 5.5 degrees; mean Gissane's angle was 110.9 +/- 5.9 degrees. Local superficial necrosis of surgical incision occurred in 2 cases, which healed well after dressing changes. Skin necrosis appeared in 1 case, where debridement and local flap transfer were performed. At the final follow-up, the mean visual analogue scale score was 1.48 +/- 1.30, and the mean American Orthopedic Foot and Ankle Society Score was 90.16 +/- 7.19. The ELA combined with a circular external fixator to assist in the reduction of calcaneal fractures achieved good reduction quality and effectively reduced postoperative complications. (c) 2022 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:437 / 443
页数:7
相关论文
共 50 条
  • [31] Limited Open Reduction and Percutaneous Screw Fixation of Displaced Intra-Articular Fracture of Calcaneus: Review of 48 Fractures
    El Khalifa, Tariq
    El Bagali, Mohammed
    Yousif, Waseem
    Hashem, Feras
    BAHRAIN MEDICAL BULLETIN, 2011, 33 (02) : 97 - 102
  • [32] Displaced intra-articular calcaneus fractures treated with the Galveston plate
    Laughlin, RT
    Carson, JG
    Calhoun, JH
    FOOT & ANKLE INTERNATIONAL, 1996, 17 (02) : 71 - 78
  • [34] Displaced Intra-Articular Fractures of the Distal Radius: Open Reduction With Internal Fixation Versus Bridging External Fixation
    Fakoor, Mohammad
    Fakoor, Morteza
    Mohammadhoseini, Payam
    TRAUMA MONTHLY, 2015, 20 (03)
  • [35] Open Reduction and Internal Fixation of Intra-articular Calcaneal Fractures in Children
    Yu, Guang-rong
    Zhao, Hong-mou
    Yang, Yun-feng
    Zhou, Jia-qian
    Li, Hai-feng
    ORTHOPEDICS, 2012, 35 (06) : E874 - E879
  • [36] LIMITED OPEN REDUCTION OF THE LUNATE FACET IN COMMINUTED INTRA-ARTICULAR FRACTURES OF THE DISTAL RADIUS
    AXELROD, T
    GREEN, J
    MCMURTRY, RY
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (03): : 372 - 377
  • [37] Cost-Effectiveness of Volar Locking Plate Compared with Augmented External Fixation for Displaced Intra-Articular Wrist Fractures
    Hammer, Ola-Lars
    Jakobsen, Rune Bruhn
    Clementsen, Stale
    Fuglesang, Hendrik
    Bjornelv, Gudrun Waaler
    Randsborg, Per-Henrik
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (23): : 2049 - 2059
  • [38] Comparison of external and percutaneous pin fixation with plate fixation for intra-articular distal radial fractures
    Macnair, Rory D.
    Ingham, Christopher J.
    Davis, Benjamin J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (08): : 1784 - 1784
  • [39] Comparison of external and percutaneous pin fixation with plate fixation for intra-articular distal radial fractures
    Leung, Frankie
    Tu, Yuan-Kun
    Chew, Winston Y. C.
    Chow, Shew-Ping
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (01): : 16 - 22
  • [40] Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
    Kumbaraci M.
    Kucuk L.
    Karapinar L.
    Kurt C.
    Coskunol E.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 173 - 178