Circular External Fixator Assisted Open Reduction Combined With Locking Plate Fixation for Intra-articular Comminuted Fractures of the Calcaneus

被引:2
|
作者
Hou, Jiguang [1 ]
Zhang, Nan [2 ]
Chen, Guodong [1 ]
Wang, Qi [1 ]
Zhang, Shenghua [1 ]
Yang, Kun [1 ]
Zang, Hongwei [1 ]
机构
[1] First Hosp Qinhuangdao, Dept Orthpaed, Qinhuangdao, Hebei, Peoples R China
[2] First Hosp Qinhuangdao, Dept Anesthesiol, Qinhuangdao, Hebei, Peoples R China
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2023年 / 62卷 / 03期
关键词
auxiliary reduction; annular external fixator; extended lateral approach traction; 3-dimensional adjustment; INTERNAL-FIXATION; PERCUTANEOUS FIXATION; OPERATIVE TREATMENT; SURGICAL-TREATMENT; COMPLICATIONS;
D O I
10.1053/j.jfas.2022.10.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Comminuted fractures of the calcaneus are relatively common and generally require surgical treatment. The quality of fracture reduction is crucial. The extended lateral approach (ELA) can better expose the fracture end and facilitate the reduction of the fracture, while it has a higher risk of postoperative skin complications. In this study, the ELA was adopted, and the calcaneal comminuted fractures were treated with circular external fixator assisted reduction to achieve the purpose of good reduction of the fracture and fewer skin complications. During 64 months, a total of 61 cases of unilateral calcaneal fractures were treated by the same surgeon and followed up for 19.28 +/- 5.28 months. During the operation, a circular external fixator was employed to fix the midfoot and the distal end of the tibia, and the calcaneal tubercle; then, the calcaneal tubercle was distracted to restore the 3-dimensional structure of the calcaneus. The ELA was utilized to reduce the articular surface fracture. The fracture was fixated with a locking plate. Postoperative radiographs were regularly reviewed. Meanwhile, Boeurohler's angle and Gissane's angle were measured. Visual analogue scale and American Orthopedic Foot and Ankle Society Score assessments were performed at the final follow-up. All fractures healed. The mean preoperative Boeurohler's angle was 9.3 +/- 10.1 degrees; the mean Gissane's angle was 110.5 +/- 14.7 degrees; the immediate postoperative mean Boeurohler's angle was 31.3 +/- 5.5 degrees; mean Gissane's angle was 110.9 +/- 5.9 degrees. Local superficial necrosis of surgical incision occurred in 2 cases, which healed well after dressing changes. Skin necrosis appeared in 1 case, where debridement and local flap transfer were performed. At the final follow-up, the mean visual analogue scale score was 1.48 +/- 1.30, and the mean American Orthopedic Foot and Ankle Society Score was 90.16 +/- 7.19. The ELA combined with a circular external fixator to assist in the reduction of calcaneal fractures achieved good reduction quality and effectively reduced postoperative complications. (c) 2022 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:437 / 443
页数:7
相关论文
共 50 条
  • [21] Temporary external fixation facilitates open reduction and internal fixation of intra-articular calcaneal fractures
    Elgamal, Tarek A.
    Tanagho, Andy E.
    Ferdinand, Rupert D.
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (06): : 738 - 741
  • [22] Intra-articular comminution worsens outcomes of distal radial fractures treated by open reduction and palmar locking plate fixation
    Yoon, J. O.
    You, S. L.
    Kim, J. K.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2017, 42 (03) : 260 - 265
  • [23] OPEN REDUCTION AND INTERNAL-FIXATION OF DISPLACED, COMMINUTED INTRA-ARTICULAR FRACTURES OF THE DISTAL END OF THE RADIUS
    BRADWAY, JK
    AMADIO, PC
    COONEY, WP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (06): : 839 - 847
  • [25] Open Reduction and External Fixation of a Comminuted Intra-articular Fifth Metacarpal Head Fracture: A Case Report
    Seaton, David
    Sidhu, Gur
    Kitsis, Christos
    Ashwood, Neil
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [26] Management of distal tibial intra-articular fractures with circular external fixation
    Lovisetti, G.
    Agus, M. A.
    Pace, F.
    Capitani, D.
    Sala, F.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2009, 4 (01): : 1 - 6
  • [27] Provisional Reduction and External Fixation of Acute Displaced Intra-articular Calcaneus Fractures: Surgical Technique and Clinical Results
    Yan, Alan Y.
    Shafiq, Babar
    Canton, Stephen P.
    Olson, Joshua T.
    Cole, Peter A.
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2023, 22 (01): : 35 - 43
  • [28] Combined Volar and Dorsal Approach for Fixation of Comminuted Intra-Articular Distal Radial Fractures
    Medlock, G.
    Smith, M.
    Johnstone, A. J.
    JOURNAL OF WRIST SURGERY, 2018, 7 (03) : 219 - 226
  • [29] The use of calcaneal anatomic plate in arthroscopically-assisted open reduction and internal fixation of intra-articular calcaneal fractures
    Wang Hong
    Zhang Qingsong
    Duan Deyu
    Yan Lijun
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2006, 26 (3): : 319 - 321
  • [30] The Use of Calcaneal Anatomic Plate in Arthroscopically-assisted Open Reduction and Internal Fixation of Intra-articular Calcaneal Fractures
    王洪
    张青松
    段德宇
    严力军
    华中科技大学学报(医学英德文版), 2006, (03) : 319 - 321