Circular External Fixator Assisted Open Reduction Combined With Locking Plate Fixation for Intra-articular Comminuted Fractures of the Calcaneus

被引:2
|
作者
Hou, Jiguang [1 ]
Zhang, Nan [2 ]
Chen, Guodong [1 ]
Wang, Qi [1 ]
Zhang, Shenghua [1 ]
Yang, Kun [1 ]
Zang, Hongwei [1 ]
机构
[1] First Hosp Qinhuangdao, Dept Orthpaed, Qinhuangdao, Hebei, Peoples R China
[2] First Hosp Qinhuangdao, Dept Anesthesiol, Qinhuangdao, Hebei, Peoples R China
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2023年 / 62卷 / 03期
关键词
auxiliary reduction; annular external fixator; extended lateral approach traction; 3-dimensional adjustment; INTERNAL-FIXATION; PERCUTANEOUS FIXATION; OPERATIVE TREATMENT; SURGICAL-TREATMENT; COMPLICATIONS;
D O I
10.1053/j.jfas.2022.10.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Comminuted fractures of the calcaneus are relatively common and generally require surgical treatment. The quality of fracture reduction is crucial. The extended lateral approach (ELA) can better expose the fracture end and facilitate the reduction of the fracture, while it has a higher risk of postoperative skin complications. In this study, the ELA was adopted, and the calcaneal comminuted fractures were treated with circular external fixator assisted reduction to achieve the purpose of good reduction of the fracture and fewer skin complications. During 64 months, a total of 61 cases of unilateral calcaneal fractures were treated by the same surgeon and followed up for 19.28 +/- 5.28 months. During the operation, a circular external fixator was employed to fix the midfoot and the distal end of the tibia, and the calcaneal tubercle; then, the calcaneal tubercle was distracted to restore the 3-dimensional structure of the calcaneus. The ELA was utilized to reduce the articular surface fracture. The fracture was fixated with a locking plate. Postoperative radiographs were regularly reviewed. Meanwhile, Boeurohler's angle and Gissane's angle were measured. Visual analogue scale and American Orthopedic Foot and Ankle Society Score assessments were performed at the final follow-up. All fractures healed. The mean preoperative Boeurohler's angle was 9.3 +/- 10.1 degrees; the mean Gissane's angle was 110.5 +/- 14.7 degrees; the immediate postoperative mean Boeurohler's angle was 31.3 +/- 5.5 degrees; mean Gissane's angle was 110.9 +/- 5.9 degrees. Local superficial necrosis of surgical incision occurred in 2 cases, which healed well after dressing changes. Skin necrosis appeared in 1 case, where debridement and local flap transfer were performed. At the final follow-up, the mean visual analogue scale score was 1.48 +/- 1.30, and the mean American Orthopedic Foot and Ankle Society Score was 90.16 +/- 7.19. The ELA combined with a circular external fixator to assist in the reduction of calcaneal fractures achieved good reduction quality and effectively reduced postoperative complications. (c) 2022 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:437 / 443
页数:7
相关论文
共 50 条
  • [1] Open Reduction Assisted With an External Fixator and Internal Fixation With Calcaneal Locking Plate for Intra-articular Calcaneal Fractures
    Yao, Hui
    Lu, Huading
    Zhao, Huiqing
    Lv, Lulu
    Hou, Gang
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (10) : 1107 - 1114
  • [2] Open reduction assisted with an external fixator and internal fixation with calcaneal locking plate for intra-articular calcaneal fractures (vol 38, pg 1107, 2017)
    Yao, H.
    Lu, H.
    Zhao, H.
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (12) : 1404 - 1404
  • [3] Open reduction and internal fixation of displaced intra-articular fractures of the calcaneus
    Huang, PJ
    Huang, HT
    Chen, TB
    Chen, JC
    Lin, YK
    Cheng, YM
    Lin, SY
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 52 (05): : 946 - 950
  • [4] Treatment of severely comminuted intra-articular fractures of the distal end of the radius by open reduction and combined internal and external fixation
    Rogachefsky, RA
    Lipson, SR
    Applegate, B
    Ouellette, EA
    Savenor, AM
    McAuliffe, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (04): : 509 - 519
  • [5] Open Reduction and Internal Fixation of Displaced Calcaneum, Intra-Articular Fractures by Locking Calcaneal Plate
    Santosha
    Gulrez, Shams
    Singh, Arambam Mahendra
    Waikhom, Sanjib
    Pakhrin, Vishal
    Mukherjee, Sagnik
    Debbarma, Rajkumar
    Prashant, Prabhu Shrinivas
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (12) : RC18 - RC21
  • [6] Open reduction and internal fixation of type II intra-articular calcaneus fractures
    Crosby, LA
    Fitzgibbons, TC
    FOOT & ANKLE INTERNATIONAL, 1996, 17 (05) : 253 - 258
  • [7] Supracutaneous plating: Use of locking compression plate as external fixator for intra-articular compound fractures
    Shakti, Panda S.
    Damodar, Panda
    Nikhil, Suri
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2016, 5 (08): : 62 - 67
  • [8] Percutaneous Reduction and Fixation of Displaced Intra-Articular Calcaneus Fractures
    DeWall, Matthew
    Henderson, Christopher E.
    McKinley, Todd O.
    Phelps, Thomas
    Dolan, Lori
    Marsh, J. L.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (08) : 466 - 472
  • [9] External Fixation with Supercutaneous Calcaneal Locking Plate for Displaced Intra-articular Calcaneal Fractures
    Zhang, Guozhu
    Jiang, Xieyuan
    Wang, Manyi
    FOOT & ANKLE INTERNATIONAL, 2012, 33 (12) : 1113 - 1118
  • [10] Open Reduction and Plate Fixation, External Fixator, and Conservative Treatment for Intra- articular Distal Radius Fractures
    Akdemir, Mehmet
    Kilic, Ali Ihsan
    Kurt, Cengizhan
    Capkin, Sercan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)