Cone beam computed tomography image guidance within a magnetic resonance imaging-only planning workflow

被引:1
|
作者
O'Connor, Laura M. [1 ,2 ,6 ]
Quinn, Alesha [1 ]
Denley, Samuel [1 ]
Leigh, Lucy [3 ]
Martin, Jarad [1 ]
Dowling, Jason A. [4 ]
Skehan, Kate [1 ]
Warren-Forward, Helen [2 ]
Greer, Peter B. [1 ,5 ]
机构
[1] Calvary Mater Hosp, Dept Radiat Oncol, Edith St, Newcastle, NSW 2298, Australia
[2] Univ Newcastle, Sch Hlth Sci, Univ Dr, Newcastle, NSW 2308, Australia
[3] Hunter Med Res Inst, Lot 1 Kookaburra Ct, New Lambton Hts, NSW 2305, Australia
[4] Commonwealth Sci & Ind Res Org CSIRO, Australian Ehlth Res Ctr, Bowen Bridge Rd, Herston, Qld 4029, Australia
[5] Univ Newcastle, Sch Informat & Phys Sci, Univ Dr, Newcastle, NSW 2308, Australia
[6] Calvary Mater Hosp, Dept Radiat Oncol, 20 Edith St, Newcastle, NSW 2298, Australia
关键词
Radiotherapy; Image-guided radiation therapy; MRI-only radiotherapy planning; Cone Beam Computed Tomography; MRI guided radiation therapy; Magnetic resonance imaging; RADIOTHERAPY; CT;
D O I
10.1016/j.phro.2023.100472
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Magnetic Resonance Imaging (MRI)-only planning workflows offer many advantages but raises challenges regarding image guidance. The study aimed to assess the viability of MRI to Cone Beam Computed Tomography (CBCT) based image guidance for MRI-only planning treatment workflows.Materials and methods: An MRI matching training package was developed. Ten radiation therapists, with a range of clinical image guidance experience and experience with MRI, completed the training package prior to matching assessment. The matching assessment was performed on four match regions: prostate gold seed, prostate soft tissue, rectum/anal canal and gynaecological. Each match region consisted of five patients, with three CBCTs per patient, resulting in fifteen CBCTs for each match region. The ten radiation therapists performed the CBCT image matching to CT and to MRI for all regions and recorded the match values.Results: The median inter-observer variation for MRI-CBCT matching and CT-CBCT matching for all regions were within 2 mm and 1 degree. There was no statistically significant association in the inter-observer variation in mean match values and radiation therapist image guidance experience levels. There was no statistically signif-icant association in inter-observer variation in mean match values for MRI experience levels for prostate soft tissue and gynaecological match regions, while there was a statistically significant difference for prostate gold seed and rectum match regions.Conclusion: The results of this study support the concept that with focussed training, an MRI to CBCT image guidance approach can be successfully implemented in a clinical planning workflow.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Megavoltage and Kilovoltage Cone-Beam Computed Tomography Image Guidance for Lung Radiotherapy
    Vlad, M.
    Sixel, K.
    Kosowan, S.
    Hart, M.
    Iqbal, F.
    El-Mallah, M.
    Vandermeer, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [22] The Accuracy of Stereotactic Radiosurgery With Cone Beam Computed Tomography Image Guidance for Trigeminal Neuralgia
    Lee, Joon K.
    Snyder, Karen C.
    Li, Haisen
    Huang, Yimei
    Wen, Ning
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 101 (02): : E42 - E43
  • [23] Influence of the Milliamperage Settings on Cone Beam Computed Tomography Imaging for Implant Planning
    Vasconcelos, Taruska Ventorini
    Neves, Frederico Sampaio
    de Freitas, Deborah Queiroz
    Flores Campos, Paulo Sergio
    Aranha Watanabe, Plauto Christopher
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (06) : 1364 - 1368
  • [24] Magnetic Resonance Imaging only Workflow for Radiotherapy Simulation and Planning in Prostate Cancer
    Kerkmeijer, L. G. W.
    Maspero, M.
    Meijer, G. J.
    van Zyp, J. R. N. van der Voort
    de Boer, C. J.
    van den Berg, C. A. T.
    CLINICAL ONCOLOGY, 2018, 30 (11) : 692 - 701
  • [25] Image acquisition: Ultrasound, computed tomography, and magnetic resonance imaging
    Langer, SG
    Carter, SJ
    Haynor, DR
    Maravella, KR
    Mattes, D
    Strandness, ED
    Stewart, BK
    WORLD JOURNAL OF SURGERY, 2001, 25 (11) : 1428 - 1437
  • [26] Image Acquisition: Ultrasound, Computed Tomography, and Magnetic Resonance Imaging
    Steve G. Langer, Ph.D.
    Stephen J. Carter, M.D.
    David R. Haynor, M.D., Ph.D.
    Kenneth R. Maravella, M.D.
    David Mattes, B.S.
    Eugene D. Strandness, Jr., M.D.
    Brent K. Stewart, Ph.D.
    World Journal of Surgery, 2001, 25 : 1428 - 1437
  • [27] Comparison of Synthetic Computed Tomography Generation Methods, Incorporating Male and Female Anatomical Differences, for Magnetic Resonance Imaging-Only Definitive Pelvic Radiotherapy
    O'Connor, Laura M.
    Choi, Jae H.
    Dowling, Jason A.
    Warren-Forward, Helen
    Martin, Jarad
    Greer, Peter B.
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [28] Assessment of image quality in maxillofacial cone-beam computed tomography imaging
    Gamache, Casey
    English, Jeryl D.
    Salas-Lopez, Anna M.
    Rong, John
    Akyalcin, Sercan
    SEMINARS IN ORTHODONTICS, 2015, 21 (04) : 248 - 253
  • [29] Validation of cone-beam computed tomography and magnetic resonance imaging of the porcine spine: a comparative study with multidetector computed tomography and anatomical specimens
    Costa de Freitas, Ricardo Miguel
    Andrade, Celi Santos
    Mendes Pereira Caldas, Jose Guilherme
    Kanas, Alexandre Fligelman
    Cabral, Richard Halti
    Tsunemi, Miriam Harumi
    Cervantes Rodriguez, Hernan Joel
    Rabbani, Said Rahnamaye
    SPINE JOURNAL, 2015, 15 (05): : 992 - 999
  • [30] Perspectives of Cone-beam Computed Tomography in Interventional Radiology: Techniques for Planning, Guidance, and Monitoring
    Barral, Matthias
    Chevallier, Olivier
    Cornelis, Francois H.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 26 (03)