Cone beam computed tomography image guidance within a magnetic resonance imaging-only planning workflow

被引:1
|
作者
O'Connor, Laura M. [1 ,2 ,6 ]
Quinn, Alesha [1 ]
Denley, Samuel [1 ]
Leigh, Lucy [3 ]
Martin, Jarad [1 ]
Dowling, Jason A. [4 ]
Skehan, Kate [1 ]
Warren-Forward, Helen [2 ]
Greer, Peter B. [1 ,5 ]
机构
[1] Calvary Mater Hosp, Dept Radiat Oncol, Edith St, Newcastle, NSW 2298, Australia
[2] Univ Newcastle, Sch Hlth Sci, Univ Dr, Newcastle, NSW 2308, Australia
[3] Hunter Med Res Inst, Lot 1 Kookaburra Ct, New Lambton Hts, NSW 2305, Australia
[4] Commonwealth Sci & Ind Res Org CSIRO, Australian Ehlth Res Ctr, Bowen Bridge Rd, Herston, Qld 4029, Australia
[5] Univ Newcastle, Sch Informat & Phys Sci, Univ Dr, Newcastle, NSW 2308, Australia
[6] Calvary Mater Hosp, Dept Radiat Oncol, 20 Edith St, Newcastle, NSW 2298, Australia
关键词
Radiotherapy; Image-guided radiation therapy; MRI-only radiotherapy planning; Cone Beam Computed Tomography; MRI guided radiation therapy; Magnetic resonance imaging; RADIOTHERAPY; CT;
D O I
10.1016/j.phro.2023.100472
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Magnetic Resonance Imaging (MRI)-only planning workflows offer many advantages but raises challenges regarding image guidance. The study aimed to assess the viability of MRI to Cone Beam Computed Tomography (CBCT) based image guidance for MRI-only planning treatment workflows.Materials and methods: An MRI matching training package was developed. Ten radiation therapists, with a range of clinical image guidance experience and experience with MRI, completed the training package prior to matching assessment. The matching assessment was performed on four match regions: prostate gold seed, prostate soft tissue, rectum/anal canal and gynaecological. Each match region consisted of five patients, with three CBCTs per patient, resulting in fifteen CBCTs for each match region. The ten radiation therapists performed the CBCT image matching to CT and to MRI for all regions and recorded the match values.Results: The median inter-observer variation for MRI-CBCT matching and CT-CBCT matching for all regions were within 2 mm and 1 degree. There was no statistically significant association in the inter-observer variation in mean match values and radiation therapist image guidance experience levels. There was no statistically signif-icant association in inter-observer variation in mean match values for MRI experience levels for prostate soft tissue and gynaecological match regions, while there was a statistically significant difference for prostate gold seed and rectum match regions.Conclusion: The results of this study support the concept that with focussed training, an MRI to CBCT image guidance approach can be successfully implemented in a clinical planning workflow.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Three Dimensional Virtual Planning Through Cone Beam Computed Tomography for Surgical Guidance Production
    Antunes, Kaline Thume
    d'Ornellas, Marcos Cordeiro
    Noedel, Daniani Deliberalli
    Dotto, Gustavo Nogara
    Ghres, Renesio Armindo
    MEDINFO 2017: PRECISION HEALTHCARE THROUGH INFORMATICS, 2017, 245 : 1250 - 1250
  • [32] Counterpoint: Opportunities and Challenges of a Magnetic Resonance Imaging-Only Radiotherapy Work Flow
    Nyholm, Tufve
    Jonsson, Joakim
    SEMINARS IN RADIATION ONCOLOGY, 2014, 24 (03) : 175 - 180
  • [33] The relationship between the articular disc in magnetic resonance imaging and the condyle in cone beam computed tomography: A retrospective study
    Chen, Benyi
    Li, Chuanjie
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2024, 125 (05)
  • [34] Cone beam computed tomography-the need for future guidance
    Efird, Jimmy T.
    Jindal, Charulata
    Podder, Tarun K.
    Kang, Kylie H.
    Biswas, Tithi
    JOURNAL OF THORACIC DISEASE, 2022, 14 (10) : 3681 - 3683
  • [35] Assessment of dosimetric and positioning accuracy of a magnetic resonance imaging-only solution for external beam radiotherapy of pelvic anatomy
    Kemppainen, Reko
    Suilamo, Sami
    Ranta, Iiro
    Pesola, Marko
    Halkola, Aleksi
    Eufemio, Alvin
    Minn, Heikki
    Keyrilainen, Jani
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 11 : 1 - 8
  • [36] Cone Beam Computed Tomography Image Guidance System for a Dedicated Intracranial Radiosurgery Treatment Unit
    Ruschin, Mark
    Komljenovic, Philip T.
    Ansell, Steve
    Menard, Cynthia
    Bootsma, Gregory
    Cho, Young-Bin
    Chung, Caroline
    Jaffray, David
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (01): : 243 - 250
  • [37] Accuracy in automatic image registration between MV cone beam computed tomography and planning kV computed tomography in image guided radiotherapy
    Kanakavelu, Nithya
    Samuel, E. James Jebaseelan
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (05) : 487 - 494
  • [38] Accuracy of magnetic resonance imaging compared with computed tomography for implant planning
    Aguiar, Marcelo F.
    Marques, Alexandre P.
    Carvalho, Antonio Carlos P.
    Cavalcanti, Marcelo G. P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (04) : 362 - 365
  • [39] Examining the Image Quality of Cone Beam Computed Tomography
    Gazarin, A.
    Moustakis, C.
    Stoeber, U.
    Eich, H. T.
    Haverkamp, U.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 : S154 - S154
  • [40] Single Magnetic Resonance Imaging vs Magnetic Resonance Imaging/Computed Tomography Planning in Cervical Cancer Brachytherapy
    Beriwal, S.
    Kim, H.
    Coon, D.
    Mogus, R.
    Heron, D. E.
    Li, X.
    Huq, M. S.