Imaging Function and Relative Light Transmission of Explanted Opacified Hydrophilic Acrylic Intraocular Lenses

被引:4
|
作者
Naujokaitis, Tadas [1 ]
Khoramnia, Ramin [1 ]
Labuz, Grzegorz [1 ]
Choi, Chul Young [1 ,2 ]
Auffarth, Gerd U. [1 ]
Tandogan, Tamer [1 ,3 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, David J Apple Ctr Vis Res, D-69120 Heidelberg, Germany
[2] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Ophthalmol, Seoul 03181, South Korea
[3] Augenklin Pallas, CH-4600 Olten, Switzerland
关键词
intraocular lens; hydrophilic; opacification; calcification; optical quality; modulation transfer function; light transmission; OPTICAL-PERFORMANCE; OPACIFICATION; CALCIFICATION; STRAYLIGHT; EXCHANGE; TRANSMITTANCE; SCATTERING; OUTCOMES;
D O I
10.3390/diagnostics13101804
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the influence of intraocular lens (IOL) opacification on the optical performance of explanted hydrophilic acrylic IOLs. We performed a laboratory analysis of 32 Lentis LS-502-1 (Oculentis GmbH, Berlin, Germany) IOLs, explanted due to opacification, in comparison with six clear unused samples of the same IOL model. Using an optical bench setup, we obtained modulation transfer function (MTF), Strehl ratio, two-dimensional MTF, and United States Air Force (USAF) chart images. In addition, we assessed light transmission through the IOLs. The MTF values of opacified IOLs at 3-mm aperture were similar to those of clear lenses, with the median (interquartile range) values of 0.74 (0.01) vs. 0.76 (0.03) at the spatial frequency of 50 line pairs per millimeter in clear and opacified IOLs, respectively. The Strehl ratio of opacified lenses was not lower than that of clear lenses. The USAF-chart analysis showed a considerable reduction in brightness in opacified IOLs. The median (interquartile range) relative light transmission of opacified IOLs in comparison to clear lenses was 55.6% (20.8%) at the aperture size of 3 mm. In conclusion, the explanted opacified IOLs had comparable MTF values to those of clear lenses but significantly reduced light transmission.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Optical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study
    Tandogan, Tamer
    Khoramnia, Ramin
    Choi, Chul Young
    Scheuerle, Alexander
    Wenzel, Martin
    Hugger, Philipp
    Auffarth, Gerd U.
    BMC OPHTHALMOLOGY, 2015, 15
  • [32] Delayed postoperative opacification of foldable hydrophilic acrylic intraocular lenses
    Huang, Yusen
    Xie, Lixin
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2011, 96B (02) : 386 - 391
  • [33] Role of silicon contamination on calcification of hydrophilic acrylic intraocular lenses
    Werner, L
    Hunter, B
    Stevens, S
    Chew, JJL
    Mamalis, N
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) : 35 - 43
  • [34] Progressive opacification of hydrophilic acrylic intraocular lenses in diabetic patients
    Lee, DH
    Seo, Y
    Joo, CK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07): : 1271 - 1275
  • [35] Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses
    Ventura, Bruna Vieira
    Ventura, Marcelo
    Lira, Wagner
    Ventura, Camila Vieira
    Santhiago, Marcony Rodrigues
    Werner, Liliana
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (03) : 149 - 154
  • [36] Calcification of hydrophilic acrylic intraocular lenses: clinical and pathological aspects
    Kocabora, MS
    Engin, G
    Kaya, G
    Yilmazli, C
    Taskapili, M
    Engin, K
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2004, 27 (08): : 871 - 876
  • [37] Surface abnormalities on hydrophilic acrylic intraocular lenses implanted by an injector
    Faschinger, CW
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (06): : 845 - 849
  • [38] Calcification of hydrophilic acrylic intraocular lenses in combined phacovitrectomy surgery
    Walker, Nathan J.
    Saldanha, Mario J.
    Sharp, John A. H.
    Porooshani, Hamid
    McDonald, Brendan M.
    Ferguson, David J. P.
    Patel, Chetan K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08): : 1427 - 1431
  • [39] Visualization of Forward Light Scatter in Opacified Intraocular Lenses and Straylight Assessment
    Son, Hyeck-Soo
    Labuz, Grzegorz
    Khoramnia, Ramin
    Yildirim, Timur M.
    Choi, Chul Young
    Knorz, Michael C.
    Auffarth, Gerd U.
    DIAGNOSTICS, 2021, 11 (08)
  • [40] Raman Spectroscopy of six explanted acrylic hydrophobic foldable intraocular lenses with glistening
    Bhattacharjee, Harsha
    Bhattacharjee, Kasturi
    Das, Dipankar
    Javeri, Henal
    Buragohain, Suklengmung
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2872 - 2876