Visualization of Forward Light Scatter in Opacified Intraocular Lenses and Straylight Assessment

被引:9
|
作者
Son, Hyeck-Soo [1 ,2 ]
Labuz, Grzegorz [1 ,2 ]
Khoramnia, Ramin [1 ,2 ]
Yildirim, Timur M. [1 ,2 ]
Choi, Chul Young [1 ,2 ,3 ]
Knorz, Michael C. [4 ]
Auffarth, Gerd U. [1 ,2 ]
机构
[1] Heidelberg Univ, David J Apple Int Lab Ocular Pathol, D-69117 Heidelberg, Germany
[2] Heidelberg Univ, Int Vis Correct Res Ctr IVCRC, Dept Ophthalmol, D-69117 Heidelberg, Germany
[3] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Ophthalmol, Sch Med, Seoul 03181, South Korea
[4] Heidelberg Univ, FreeVis LASIK Ctr, Med Fac Mannheim, D-68167 Mannheim, Germany
关键词
ray propagation; imaging technique; intraocular lens; opacification; straylight; CALCIFICATION;
D O I
10.3390/diagnostics11081512
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Qualitative visualization of forward light scatter and quantitative straylight measurement of intraocular lenses (IOLs). Methods: We analyzed two calcified IOL-explants, the Euromaxx ALI313Y (Argonoptics GmbH) and the LS-312 MF30 (Oculentis BV), one IOL with artificially induced glistenings (PC-60AD, Hoya), and one control (CT Asphina 409MP, Carl Zeiss Meditec AG) free of any opacification. Analysis included light microscopy, qualitative light scatter visualization using ray propagation imaging technique, and quantitative straylight measurement using C-Quant (Oculus). Results: More light scattering effect-visible as increased light intensity outside the IOUs main focus-was evident in all opacified IOLs than the control. The highest straylight levels were observed in the Euromaxx (289.71 deg(2)/sr), which showed extensive granular deposits throughout its optic, followed by the MF30 (78.58 deg(2)/sr), which only showed opacification in its center. The glistenings-IOL demonstrated numerous microvacuoles within the optic and had straylight levels of 22.6 deg(2)/sr, while the control showed the lowest straylight levels (1.7 deg(2)/sr). Conclusions: Ray propagation imaging technique allowed qualitative assessment of off-axis veils of light that result from increased forward light scattering. Straylight was increased in all opacified lenses compared to the clear control lens. The IOL opacifications are significant sources of glare.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Optical Pathway Imaging and Straylight Evaluation of Opacified Intraocular Lenses
    Son, Hyeck Soo
    Yildirim, Timur Mert
    Labuz, Grzegorz
    Auffarth, Gerd
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [2] Technique for measuring forward light scatter in intraocular lenses
    Das, Kamal K.
    Stover, John C.
    Schwiegerling, Jim
    Karakelle, Mutlu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05): : 770 - 778
  • [3] Method for in vitro assessment of straylight from intraocular lenses
    Labuz, Grzegorz
    Vargas-Martin, Fernando
    van den Berg, Thomas J. T. P.
    Lopez-Gil, Norberto
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (11): : 4457 - 4464
  • [4] Forward Light Scatter, Stray Light and Image Quality in Intraocular Lenses at Various Light Scattering Angles
    Das, Kamal K.
    Werner, Liliana
    Stover, John
    Schwiegerling, Jim
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [5] Light-scattering characteristics of explanted opacified Aquasense intraocular lenses
    van der Meulen, I. J. E.
    Porooshani, H.
    van den Berg, T. J. T. P.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (06) : 830 - 832
  • [6] Straylight in Different Types of Intraocular Lenses
    Arias, Augusto
    Ginis, Harilaos
    Artal, Pablo
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (12): : 1 - 7
  • [7] Straylight from explanted intraocular lenses
    Labuz, Grzegorz
    Papadatou, Eleni
    Van den Berg, Thomas J. T. P.
    Vargas-Martin, Fernando
    Lopez-Gil, Norberto
    Reus, Nicolaas J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [8] Forward Light Scatter, Modulation Transfer Function and Image Quality Measurements for AcrySof Natural Intraocular Lenses
    Das, Kamal
    Schwiegerling, Jim
    Karakelle, Mutlu
    Stover, John
    Ong, Marcia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [9] Imaging Function and Relative Light Transmission of Explanted Opacified Hydrophilic Acrylic Intraocular Lenses
    Naujokaitis, Tadas
    Khoramnia, Ramin
    Labuz, Grzegorz
    Choi, Chul Young
    Auffarth, Gerd U.
    Tandogan, Tamer
    DIAGNOSTICS, 2023, 13 (10)
  • [10] Exchange technique for opacified hydrophilic acrylic intraocular lenses
    Voros, GM
    Strong, NP
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (04) : 465 - 467