Visualization of Forward Light Scatter in Opacified Intraocular Lenses and Straylight Assessment

被引:9
|
作者
Son, Hyeck-Soo [1 ,2 ]
Labuz, Grzegorz [1 ,2 ]
Khoramnia, Ramin [1 ,2 ]
Yildirim, Timur M. [1 ,2 ]
Choi, Chul Young [1 ,2 ,3 ]
Knorz, Michael C. [4 ]
Auffarth, Gerd U. [1 ,2 ]
机构
[1] Heidelberg Univ, David J Apple Int Lab Ocular Pathol, D-69117 Heidelberg, Germany
[2] Heidelberg Univ, Int Vis Correct Res Ctr IVCRC, Dept Ophthalmol, D-69117 Heidelberg, Germany
[3] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Ophthalmol, Sch Med, Seoul 03181, South Korea
[4] Heidelberg Univ, FreeVis LASIK Ctr, Med Fac Mannheim, D-68167 Mannheim, Germany
关键词
ray propagation; imaging technique; intraocular lens; opacification; straylight; CALCIFICATION;
D O I
10.3390/diagnostics11081512
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Qualitative visualization of forward light scatter and quantitative straylight measurement of intraocular lenses (IOLs). Methods: We analyzed two calcified IOL-explants, the Euromaxx ALI313Y (Argonoptics GmbH) and the LS-312 MF30 (Oculentis BV), one IOL with artificially induced glistenings (PC-60AD, Hoya), and one control (CT Asphina 409MP, Carl Zeiss Meditec AG) free of any opacification. Analysis included light microscopy, qualitative light scatter visualization using ray propagation imaging technique, and quantitative straylight measurement using C-Quant (Oculus). Results: More light scattering effect-visible as increased light intensity outside the IOUs main focus-was evident in all opacified IOLs than the control. The highest straylight levels were observed in the Euromaxx (289.71 deg(2)/sr), which showed extensive granular deposits throughout its optic, followed by the MF30 (78.58 deg(2)/sr), which only showed opacification in its center. The glistenings-IOL demonstrated numerous microvacuoles within the optic and had straylight levels of 22.6 deg(2)/sr, while the control showed the lowest straylight levels (1.7 deg(2)/sr). Conclusions: Ray propagation imaging technique allowed qualitative assessment of off-axis veils of light that result from increased forward light scattering. Straylight was increased in all opacified lenses compared to the clear control lens. The IOL opacifications are significant sources of glare.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Light scattering, straylight, and optical quality in hydrophobic acrylic intraocular lenses with subsurface nanoglistenings
    Werner, Liliana
    Stover, John C.
    Schwiegerling, Jim
    Das, Kamal K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 148 - 156
  • [12] Straylight from glistenings in intraocular lenses: In vitro study
    Labuz, Grzegorz
    Reus, Nicolaas J.
    van den Berg, Thomas J. T. P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (01): : 102 - 108
  • [13] Effect of yellow tinted spectacle lenses on intraocular straylight
    Ikaunieks, G.
    Stepanovs, A.
    Ozolinsh, M.
    PERCEPTION, 2010, 39 : 169 - 169
  • [14] Straylight measurements in intraocular lenses with an optical integration method
    Pennos, Alexandros
    Ginis, Harilaos S.
    Gambin, Adrian
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [15] Retinal straylight in patients with monofocal and multifocal intraocular lenses
    Cervino, Alejandro
    Hosking, Sarah L.
    Montes-Mico, Robert
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 441 - 446
  • [16] Spectroscopic study of explanted opacified hydrophilic acrylic intraocular lenses
    Fodor, Mariann
    Petrovski, Goran
    Moe, Morten C.
    Biro, Zsolt
    Nemeth, Gabor
    Dinya, Zoltan
    Tornai, Ildiko
    Ujvari, Tamas
    Berta, Andras
    Facsko, Andrea
    ACTA OPHTHALMOLOGICA, 2011, 89 (02) : E161 - E166
  • [17] Assessment of straylight and the modulation transfer function of intraocular lenses with centrally localized opacification associated with the intraocular injection of gas
    Labuz, Grzegorz
    Yildirim, Timur M.
    van den Berg, Thomas J. T. P.
    Khoramnia, Ramin
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (05): : 615 - 622
  • [18] Combining in vitro test methods for measuring light scatter in intraocular lenses
    van der Mooren, Marrie
    van den Berg, Tom
    Coppens, Joris
    Piers, Patricia
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (03): : 505 - 510
  • [19] Laboratory evaluation of higher-order aberrations and light scattering in explanted opacified intraocular lenses
    Grzegorz Łabuz
    Timur M. Yildirim
    Gerd U. Auffarth
    Hyeck-Soo Son
    Ramin Khoramnia
    Eye and Vision, 8
  • [20] Laboratory evaluation of higher-order aberrations and light scattering in explanted opacified intraocular lenses
    Labuz, Grzegorz
    Yildirim, Timur M.
    Auffarth, Gerd U.
    Son, Hyeck-Soo
    Khoramnia, Ramin
    EYE AND VISION, 2021, 8 (01)