Mineral quantitative characterization method based on basis material decomposition model by dual-energy computed tomography

被引:0
|
作者
Zhi, Weijuan [1 ]
Zou, Jing [1 ]
Zhao, Jintao [2 ]
Xia, Xiaoqin [3 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300000, Peoples R China
[2] Tianjin Univ Technol & Educ, Tianjin Key Lab Informat Sensing & Intelligent Co, Tianjin, Peoples R China
[3] Zhejiang Normal Univ, Coll Math Med, Jinhua, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual-energy computed tomography; basis material decomposition; mineral quantitative characterization; basis material determination; ATOMIC-NUMBER; CT; OPTIMIZATION; DENSITY;
D O I
10.3233/XST-221324
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Dual-energy computed tomography (DECT) can reconstruct electron density rho(e) and effective atomic number Z(eff) distribution for material discrimination. Image-domain basis material decomposition (IBMD) method is a widely used DECT method. However, IBMD method cannot be used for mineral identification directly due to limitations of complex basis material determination, beam hardening artifacts, and inherent errors caused by approximate empirical formulas. OBJECTIVE: This study proposes an improved IBMD (IIBMD) method to overcome the above limitations. METHODS: In IIBMD method, the composition of basis material is optimized to obtain accurate decomposition coefficients, which enables accurate rho(e) and Zeff distribution. Moreover, the thickness of basis material is optimized to reduce the effect of beam hardening. Furthermore, two formulas in place of empirical formulas are proposed to calculate rho(e) and Zeff. Finally, a threshold technique is applied to separate different mineral phases. RESULTS: Numerical simulations and practical experiments using a photon-counting detector CT system are implemented to verify IIBMD method. Results show that the relative errors of rho(e) and Z(eff) for seven common minerals are down to 5%, lower than most of the existing DECT methods for rocks. Reasonable volume fraction results of mineral phases are thus obtained through threshold segmentation. CONCLUSIONS: This study demonstrates that the proposed IIBMD method has high practical value in mineralogical identification.
引用
收藏
页码:373 / 391
页数:19
相关论文
共 50 条
  • [41] Development of a Dual-Energy Computed Tomography-Based Segmentation Method for Collateral Ligaments: A Porcine Knee Model
    Du, Yeh-Ming
    Yang, Qing-Fang
    Shen, Wan-Ting
    Huang, Hsuan-Ming
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2019, 39 (01) : 96 - 101
  • [42] Development of a Dual-Energy Computed Tomography-Based Segmentation Method for Collateral Ligaments: A Porcine Knee Model
    Yeh-Ming Du
    Qing-Fang Yang
    Wan-Ting Shen
    Hsuan-Ming Huang
    Journal of Medical and Biological Engineering, 2019, 39 : 96 - 101
  • [43] Numerical Simulation for Basis Material Decomposition and Image Reconstruction of Dual-energy CT
    He, Fangfang
    Sun, Fengrong
    Wang, Naishun
    Wu, Lijun
    Babyn, Paul
    Yao, Guihua
    Zhong, Hai
    PROCEEDINGS OF 2019 IEEE 3RD INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC 2019), 2019, : 1314 - 1318
  • [44] Material decomposition with dual- and multi-energy computed tomography
    Rajesh Bhayana
    Anushri Parakh
    Avinash Kambadakone
    MRS Communications, 2020, 10 : 558 - 565
  • [45] Material decomposition with dual- and multi-energy computed tomography
    Bhayana, Rajesh
    Parakh, Anushri
    Kambadakone, Avinash
    MRS COMMUNICATIONS, 2020, 10 (04) : 558 - 565
  • [46] Multi-material gap measurements using dual-energy computed tomography
    Jansson, Anton
    Hermanek, Petr
    Pejryd, Lars
    Carmignato, Simone
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2018, 54 : 420 - 426
  • [47] An algorithm for noise correction of dual-energy computed tomography material density images
    Rafael Simon Maia
    Christian Jacob
    Amy K. Hara
    Alvin C. Silva
    William Pavlicek
    Mitchell J. Ross
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 87 - 100
  • [48] Dual-energy computed tomography diagnostics for gout
    Rech, H. J.
    Cavallaro, A.
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 2017, 76 (07): : 580 - 588
  • [49] Imaging of nanoparticles with dual-energy computed tomography
    Ducote, J. L.
    Alivov, Y.
    Molloi, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07): : 2031 - 2044
  • [50] An algorithm for noise correction of dual-energy computed tomography material density images
    Maia, Rafael Simon
    Jacob, Christian
    Hara, Amy K.
    Silva, Alvin C.
    Pavlicek, William
    Ross, Mitchell J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (01) : 87 - 100