Mineral quantitative characterization method based on basis material decomposition model by dual-energy computed tomography

被引:0
|
作者
Zhi, Weijuan [1 ]
Zou, Jing [1 ]
Zhao, Jintao [2 ]
Xia, Xiaoqin [3 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300000, Peoples R China
[2] Tianjin Univ Technol & Educ, Tianjin Key Lab Informat Sensing & Intelligent Co, Tianjin, Peoples R China
[3] Zhejiang Normal Univ, Coll Math Med, Jinhua, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual-energy computed tomography; basis material decomposition; mineral quantitative characterization; basis material determination; ATOMIC-NUMBER; CT; OPTIMIZATION; DENSITY;
D O I
10.3233/XST-221324
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Dual-energy computed tomography (DECT) can reconstruct electron density rho(e) and effective atomic number Z(eff) distribution for material discrimination. Image-domain basis material decomposition (IBMD) method is a widely used DECT method. However, IBMD method cannot be used for mineral identification directly due to limitations of complex basis material determination, beam hardening artifacts, and inherent errors caused by approximate empirical formulas. OBJECTIVE: This study proposes an improved IBMD (IIBMD) method to overcome the above limitations. METHODS: In IIBMD method, the composition of basis material is optimized to obtain accurate decomposition coefficients, which enables accurate rho(e) and Zeff distribution. Moreover, the thickness of basis material is optimized to reduce the effect of beam hardening. Furthermore, two formulas in place of empirical formulas are proposed to calculate rho(e) and Zeff. Finally, a threshold technique is applied to separate different mineral phases. RESULTS: Numerical simulations and practical experiments using a photon-counting detector CT system are implemented to verify IIBMD method. Results show that the relative errors of rho(e) and Z(eff) for seven common minerals are down to 5%, lower than most of the existing DECT methods for rocks. Reasonable volume fraction results of mineral phases are thus obtained through threshold segmentation. CONCLUSIONS: This study demonstrates that the proposed IIBMD method has high practical value in mineralogical identification.
引用
收藏
页码:373 / 391
页数:19
相关论文
共 50 条
  • [31] A novel image optimization method for dual-energy computed tomography
    Hao, Jia
    Kang, Kejun
    Zhang, Li
    Chen, Zhiqiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 722 : 34 - 42
  • [32] SYSTEMATIC BIAS IN BASIS MATERIAL DECOMPOSITION APPLIED TO QUANTITATIVE DUAL-ENERGY X-RAY-IMAGING
    GINGOLD, EL
    HASEGAWA, BH
    MEDICAL PHYSICS, 1992, 19 (01) : 25 - 33
  • [33] Quantitative Study of Vertebral Body and Paravertebral Muscle Degeneration Based on Dual-Energy Computed Tomography: Correlation With Bone Mineral Density
    Liu, Zhenghua
    Zhang, Yuting
    Huang, Dageng
    Ma, Xiaowen
    Duan, Yaqing
    Jiang, Yonghong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (01) : 86 - 92
  • [34] Dual-Energy Computed Tomography Virtual Noncalcium Technique in Diagnosing Osteoporosis: Correlation With Quantitative Computed Tomography
    Liu, Zhenghua
    Zhang, Yuting
    Liu, Zhou
    Kong, Jiangtao
    Huang, Dageng
    Zhang, Xiaoyue
    Jiang, Yonghong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 452 - 457
  • [35] Achilles Tendinopathy and Partial Tear Diagnosis Using Dual-Energy Computed Tomography Collagen Material Decomposition Application
    Mallinson, Paul I.
    Stevens, Chris
    Reisinger, Clemens
    Nicolaou, Savvas
    Munk, Peter L.
    Ouellette, Hugue
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 475 - 477
  • [36] Dual-energy computed tomography material decomposition improves prediction accuracy of hematoma expansion in traumatic intracranial hemorrhage
    Lee, Jungbin
    Park, Sung-Tae
    Hwang, Sun-Chul
    Kim, Jung Youn
    Lee, A. Leum
    Chang, Kee-Hyun
    PLOS ONE, 2023, 18 (07):
  • [37] Dual-Energy Computed Tomography Dose Reduction, Series Reduction, and Contrast Load Reduction in Dual-Energy Computed Tomography
    Parakh, Anushri
    Macri, Francesco
    Sahani, Dushyant
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 601 - +
  • [38] Dual-Energy Computed Tomography for Stone Type Assessment: A Pilot Study of Dual-Energy Computed Tomography with Five Indices
    Rudenko, Vadim
    Serova, Natalia
    Kapanadze, Lida
    Taratkin, Mark
    Okhunov, Zhamshid
    Leonard, Stephen P.
    Ritter, Manuel
    Kriegmair, Maximilian
    Snurnitsyna, Olesya
    Kozlov, Vasiliy
    Laukhtina, Ekaterina
    Arshiev, Magomed
    Aleksandrova, Ksenia
    Salomon, Georg
    Enikeev, Dmitry
    Glybochko, Petr
    JOURNAL OF ENDOUROLOGY, 2020, 34 (09) : 893 - 899
  • [39] Characterization of ureteral stents by dual-energy computed tomography: Clinical implications
    Ibrahim, El-Sayed H.
    Haley, William E.
    Jepperson, Maria A.
    Wehle, Michael J.
    Cernigliaro, Joseph G.
    WORLD JOURNAL OF RADIOLOGY, 2014, 6 (08): : 625 - 628
  • [40] COMPARISON OF DUAL-PHOTON ABSORPTIOMETRY AND DUAL-ENERGY COMPUTED-TOMOGRAPHY FOR VERTEBRAL MINERAL
    MAZESS, RB
    VETTER, J
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (03) : 624 - 625