Fatigue Performance of a Novel Steel-Concrete Joint of a Long-Span High-Speed Railway Hybrid Girder-Cable-Stayed Bridge

被引:2
|
作者
Shi, Zhou [1 ]
Li, Yingming [1 ]
Yang, Yi [1 ]
Zhao, Xupo [1 ]
Yu, Wanqing [1 ]
机构
[1] Southwest Jiaotong Univ, Dept Bridge Engn, 111 Sect Northbound 1,Second Ring Rd, Chengdu 610031, Peoples R China
关键词
High-speed railway; Hybrid girder-cable-stayed bridge; Steel-concrete joint; Fatigue performance; Model test; Parametric analysis; SHEAR CONNECTOR; BEHAVIOR;
D O I
10.1061/JBENF2.BEENG-6425
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The steel-concrete joint (SCJ) of a railway hybrid girder-cable-stayed bridge transmits tremendous internal forces, resulting in complex structure and stress. The existing complex SCJs lead to difficulties in on-site concrete construction, and the complex stress of the SCJ under train load is prone to diseases such as steel concrete fatigue detachment and cracking. To investigate the complex fatigue performance of a novel SCJ for a long-span high-speed railway hybrid box girder-cable-stayed bridge with a main span of 672 m, finite-element analysis (FEA) and a 1:2 scaled fatigue model test with 2.15 million cycles were conducted. The results showed that the numerical fatigue stresses of the SCJ exhibited a significant shear lag effect in the transverse direction with unfavorable fatigue stresses at the side box. After 1.70 million loading cycles, all the steel plates of the test model remained intact, indicating good fatigue resistance during the design life. Cracks appeared at the junction between the horizontal diaphragm and the web of the steel transition segment (STS) after 1.85 million cycles, showing a fatigue life of 118 years. The measured fatigue crack life of the concrete deck over the postanchor position of the prestressed tendons in the STS was 30.5 years for the local concentrated tensile stress, which can be improved by casting the concrete after the tendons are prestressed. No fracture or other abnormalities occurred in the shear studs and perforated rib (PBL) rebars, and the deflection of the test model and the slip between the steel and concrete were insignificant during the fatigue tests, indicating the good fatigue performance of the SCJ, which was better than that of the STS. The thickness of the bearing plate and diameter of the shear studs for the actual SCJ were suggested to be 40-60 and 16-25 mm, respectively, based on a parametric study.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Deformation Control Limits for Long-Span Concrete Arch Bridge of High-Speed Railway
    Zheng X.
    Xu X.
    Chen K.
    You L.
    Zhongguo Tiedao Kexue/China Railway Science, 2019, 40 (03): : 60 - 64
  • [42] Study on the Effect of Temperature on the Alignment of a Long-Span Steel-Concrete Composite Beam Track Cable-Stayed Bridge
    Li, Xiaogang
    Huang, Xiangsheng
    Ding, Peng
    Chen, Xiaohu
    Wang, Qiansong
    Cen, Sihan
    APPLIED SCIENCES-BASEL, 2024, 14 (22):
  • [43] Study of Adaptability of Ballastless Tracks on Long-Span High-Speed Railway Steel Bridge
    Li, Wei
    Bridge Construction, 2020, 50 : 41 - 47
  • [44] Finite element analysis of steel and concrete joint section of railway hybrid box girder cable-stayed bridge
    Yao, Ya-Dong
    Yang, Yong-Qing
    Liu, Zhen-Biao
    Pu, Qian-Hui
    Shi, Zhou
    Bridge Construction, 2015, 45 (01) : 45 - 50
  • [45] Lateral Isolation System of a Long-Span Cable-Stayed Bridge with Heavyweight Concrete Girder in a High Seismic Region
    Guan, Zhongguo
    You, Han
    Li, Jian-zhong
    JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (01)
  • [46] Dynamic Responses of Long-Span Steel Truss Girder Cable-Stayed Bridge With a Single Pylon
    Zeng, Yong
    Wei, Jiahao
    Zeng, Yutong
    Xiao, Yunchuan
    Mao, Hongwei
    Huang, Ming
    Xiang, Zhongfu
    Zhou, Jianting
    ADVANCES IN CIVIL ENGINEERING, 2025, 2025 (01)
  • [47] Load transfer mechanism of steel-concrete joint in hybrid girder cable-stayed bridges
    Wang, Taiqi
    Liu, Yuqing
    Wang, Shumin
    Ma, Guang
    Yang, Xinran
    Wang, Sihao
    Journal of Constructional Steel Research, 2025, 230
  • [48] Sensitivity analysis on finished state of a long-span arch supported single pylon cable-stayed bridge for high-speed railway
    Zhu, Jiachong
    Huang, Tianli
    Zhou, Chaoyang
    Xu, Buqi
    Journal of Railway Science and Engineering, 2021, 18 (09) : 2244 - 2254
  • [49] Parametric analysis on buffeting performance of a long-span high-speed railway suspension bridge
    Zhao Kai-yong
    Wang Hao
    Tao Tian-you
    Gao Hui
    Wu Tong
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2022, 29 (08) : 2574 - 2588
  • [50] Performance analysis of slab track structures on long-span high-speed railway bridge
    Ding, Yu
    Xin, Tao
    Wang, Pengsong
    Huo, Hailong
    Chen, Peng
    International Journal of COMADEM, 2019, 22 (03): : 39 - 44