Double-Tuned Birdcage Radio Frequency Coil for 7 T MRI: Optimization, Construction and Workbench Validation

被引:0
|
作者
Retico, Alessandra [1 ]
Maggiorelli, Francesca [1 ,2 ,3 ]
Giovannetti, Giulio [4 ]
Boskamp, Eddy [5 ]
Robb, Fraser [6 ]
Fantasia, Marco [7 ]
Galante, Angelo [7 ,8 ,9 ]
Alecci, Marcello [7 ,8 ,9 ]
Tiberi, Gianluigi [10 ,11 ]
Tosetti, Michela [3 ,12 ]
机构
[1] Natl Inst Nucl Phys INFN, Pisa Div, I-56127 Pisa, Italy
[2] Univ Siena, Dept Phys Sci Earth & Environm DSFTA, I-53100 Siena, Italy
[3] Imago7 Fdn, I-56128 Pisa, Italy
[4] Natl Res Council CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[5] Hyperfine Res Inc, Guilford, CT 06437 USA
[6] GE Healthcare Inc, Aurora, OH 44202 USA
[7] Univ Aquila, Dept Life Hlth & Environm Sci MESVA, I-67100 Laquila, Italy
[8] INFN, Gran Sasso Natl Lab, I-67100 Laquila, Italy
[9] Univ Aquila, CNR, SPIN, Dept Phys & Chem Sci, I-67100 Laquila, Italy
[10] London South Bank Univ, Sch Engn, London SE1 0AA, England
[11] Umbria Bioengn Technol UBT Srl, I-06081 Perugia, Italy
[12] IRCCS Stella Maris Fdn, I-56128 Pisa, Italy
关键词
UHF MRI; 7 T MRI; RF coils; double tuned; sodium imaging; TISSUE SODIUM CONCENTRATION; HUMAN BRAIN; MYOCARDIAL-INFARCTION; NA-23; MRI; QUADRATURE; DESIGN; SPECTROSCOPY; MUSCLE; PERFORMANCE; VIABILITY;
D O I
10.3390/electronics12040901
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim of the present study is the optimization, construction, and workbench validation of a double-tuned H-1- Na-23 volume radio frequency (RF) coil suitable for human head imaging at 7 T, based on the birdcage geometry. The birdcage-like design which is considered is the four-ring model, in which two standard birdcage-like structures with the same diameters are nested along the longitudinal axis. Simulations based on Maxwell's equations are performed to evaluate the RF magnetic field homogeneity and the RF coil efficiency varying the coil geometrical parameters. The RF magnetic field homogeneity is evaluated both on the transverse (z = 0) and longitudinal (y = 0) planes without performing the impedance matching procedure, so that the RF coil symmetry is not perturbed by the matching network. The RF coil efficiency is instead dependent on the effective coil input RF power, and it is evaluated after matching the coil, so that the reflected power is minimized, assuming that the stimulation power is totally delivered to the RF coil. Considering the simulation results and the target application, the useful RF coil geometrical parameters are fixed. The four-ring model, which showed the best performances, has been built and tested on a workbench, using a cylindrical phantom filled with a 0.05 M saline solution as load. This provides the first example of a four-ring realization intended H-1- Na-23 for human head imaging at 7 T.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] An Extended Theory and Method for Double-Tuned Conformal Birdcage Coil in MRI
    Xie, Junyao
    Guan, Jinglong
    Yao, Kaiwen
    Liu, Min
    You, Xueqiu
    Sun, Huijun
    Chen, Zhong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 11
  • [2] A DESIGN FOR A DOUBLE-TUNED BIRDCAGE COIL FOR USE IN AN INTEGRATED MRI/MRS EXAMINATION
    ISAAC, G
    SCHNALL, MD
    LENKINSKI, RE
    VOGELE, K
    JOURNAL OF MAGNETIC RESONANCE, 1990, 89 (01): : 41 - 50
  • [3] Use of Tailored Higher Modes of a Birdcage to Design a Simple Double-Tuned Proton/Phosphorus Coil for Human Calf Muscle Studies at 7 T
    Webb, A. G.
    Smith, N. B.
    Aussenhofer, S.
    Kan, H. E.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2011, 39B (02) : 89 - 97
  • [4] Numerical and Workbench Design of 2.35 T Double-Tuned (1H/23Na) Nested RF Birdcage Coils Suitable for Animal Size MRI
    Fantasia, Marco
    Galante, Angelo
    Maggiorelli, Francesca
    Retico, Alessandra
    Fontana, Nunzia
    Monorchio, Agostino
    Alecci, Marcello
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (10) : 3175 - 3186
  • [5] Design and use of a folded four-ring double-tuned birdcage coil for rat brain sodium imaging at 9.4 T
    Ha, YongHyun
    Choi, Chang-Hoon
    Worthoff, Wieland A.
    Shymanskaya, Aliaksandra
    Schoeneck, Michael
    Willuweit, Antje
    Felder, Joerg
    Shah, N. Jon
    JOURNAL OF MAGNETIC RESONANCE, 2018, 286 : 110 - 114
  • [6] Design, construction, and use of a tapered-spiral, quadrature 1H/23Na double-tuned coil for in ovo MRI at 7 T
    Choi, Chang-Hoon
    Hong, Suk-Min
    Felder, Joerg
    Bruch, Maximilian
    Worthoff, Wieland A.
    Krause, Sandra
    Shah, N. Jon
    MEDICAL PHYSICS, 2024, 51 (12) : 8761 - 8767
  • [7] Computational and Experimental Optimization of a Double-Tuned 1H/31P Four-Ring Birdcage Head Coil for MRS at 3T
    Duan, Yunsuo
    Peterson, Bradley S.
    Liu, Feng
    Brown, Truman R.
    Ibrahim, Tamer S.
    Kangarlu, Alayar
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (01) : 13 - 22
  • [8] Double-Tuned Surface 1H-23Na Radio Frequency Coils at 7 T: Comparison of Three Decoupling Methods
    Maggiorelli, Francesca
    Boskamp, Eddy B.
    Tiberi, Gianluigi
    Retico, Alessandra
    Symms, Mark R.
    Tosetti, Michela
    Robb, Fraser
    APPLIED MAGNETIC RESONANCE, 2019, 50 (05) : 649 - 661
  • [9] Double-Tuned Surface 1H–23Na Radio Frequency Coils at 7 T: Comparison of Three Decoupling Methods
    Francesca Maggiorelli
    Eddy B. Boskamp
    Gianluigi Tiberi
    Alessandra Retico
    Mark R. Symms
    Michela Tosetti
    Fraser Robb
    Applied Magnetic Resonance, 2019, 50 : 649 - 661
  • [10] DESIGN AND CONSTRUCTION OF A SIMPLE DOUBLE-TUNED, SINGLE-INPUT SURFACE-COIL PROBE
    GONNELLA, NC
    SILVERMAN, RF
    JOURNAL OF MAGNETIC RESONANCE, 1989, 85 (01): : 24 - 34