Activity Evaluation Methodology for the Disposed Medical Linear Accelerators

被引:0
|
作者
Kwon, Na Hye [1 ,2 ]
Jang, Young Jae [3 ,4 ]
Kim, Kum Bae [4 ,5 ]
Yu, Ji Hyun [6 ]
Kim, Jinsung [1 ,2 ,7 ]
Kim, Dong Wook [1 ,2 ]
Choi, Sang Hyoun [4 ,5 ]
机构
[1] Yonsei Univ, Heavy Ion Therapy Res Inst, Yonsei Canc Ctr, Dept Radiat Oncol,Coll Med, Seoul 03722, South Korea
[2] Yonsei Univ, Med Phys & Biomed Engn Lab MPBEL, Coll Med, Seoul 03722, South Korea
[3] Korea Univ, Dept Accelerator Sci, Sejong 30015, South Korea
[4] Korea Inst Radiol & Med Sci, Res Team Radiol Phys & Engn, Seoul 01812, South Korea
[5] Korea Inst Radiol & Med Sci, Dept Radiat Oncol, Seoul 01812, South Korea
[6] Sae An Enertech Corp, R&D Inst, Daejeon 34016, South Korea
[7] Oncosoft Inc, Seoul 03787, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 01期
基金
新加坡国家研究基金会;
关键词
radioactive waste; disposed linear accelerators; radioactivation; in situ HPGe detectors; gamma spectroscopy;
D O I
10.3390/app13010528
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
For the medical linear accelerators (linac) that utilize more than 10 MV of photon energy, components inside the linac head become radioactivate during the 10-15-year operating cycle. Prior to disposal, radioactive waste must be evaluated for activity, and the same procedure should be followed for medical linacs. In the Republic of Korea, regulation and methodology for the radioactivity evaluation for the medical linac is not established yet. In this study, we employed gamma spectroscopy and a survey meter for evaluating the radioactivity of medical linac components. The components of the Siemens linac considered in this study were classified after decommissioning, and dose rates were measured to up to a 5 cm distance from the component surfaces by using a survey meter. Radionuclides from components were detected using an in situ HPGe detector. Based on the type of radionuclides and dose rate, we estimated the radioactivity of the components. We studied the feasibility of the methodology for disposing of radioactive components by using the in situ HPGe detector.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Analysis of Activated Materials of Disposed Medical Linear Accelerators according to Clearance Level for Self-Disposal
    Jang, Young Jae
    Kwon, Na Hye
    Park, Seong Hee
    Choi, Yona
    Kim, Kum Bae
    Kim, Dong Wook
    Bhang, Suk Ho
    Choi, Sang Hyoun
    SUSTAINABILITY, 2023, 15 (05)
  • [2] Characteristics of induced activity from medical linear accelerators
    Wang, Y
    Evans, M
    Podgorsak, E
    MEDICAL PHYSICS, 2005, 32 (06) : 2020 - 2020
  • [3] Characteristics of induced activity from medical linear accelerators
    Wang, YZ
    Evans, MDC
    Podgorsak, EB
    MEDICAL PHYSICS, 2005, 32 (09) : 2899 - 2910
  • [4] Neutron dose rate evaluation for medical linear accelerators
    Facure, A
    Falcao, RC
    Da Silva, AX
    Crispim, VR
    RADIATION PROTECTION DOSIMETRY, 2004, 111 (01) : 101 - 103
  • [5] Endpoint energy of linear medical accelerators
    Krmar, M
    Ganezer, K
    Pantelic, G
    Krstonosic, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 532 (03): : 533 - 537
  • [6] Medical applications of electron linear accelerators
    Wambersie, A
    Gahbauer, RA
    CAS - CERN ACCELERATOR SCHOOL - CYCLOTRONS, LINACS AND THEIR APPLICATIONS, 1996, 96 (02): : 229 - 248
  • [7] USE FACTORS FOR MEDICAL LINEAR ACCELERATORS
    COBB, PD
    BJARNGARD, BE
    HEALTH PHYSICS, 1976, 31 (05): : 463 - 465
  • [8] Production of medical radioisotopes with linear accelerators
    Starovoitova, Valeriia N.
    Tchelidze, Lali
    Wells, Douglas P.
    APPLIED RADIATION AND ISOTOPES, 2014, 85 : 39 - 44
  • [9] HAZARD REVIEWS AND MEDICAL LINEAR ACCELERATORS
    FAREL, DG
    QUALITY PROGRESS, 1983, 16 (02) : 34 - 34
  • [10] Automating Laser Calibration for Medical Linear Accelerators
    VanGenderen, B.
    Appeldoorn, C.
    Ramaseshan, R.
    Dearden, C.
    Ho, J.
    Long, X. L.
    2016 IEEE SENSORS, 2016,