Neutron dose rate evaluation for medical linear accelerators

被引:8
|
作者
Facure, A
Falcao, RC
Da Silva, AX
Crispim, VR
机构
[1] Comis Nacl Energia Atom, BR-22294900 Rio De Janeiro, Brazil
[2] UFRJ, CT, EE, DNC,COPPE,PEN, BR-21945970 Rio De Janeiro, Brazil
关键词
D O I
10.1093/rpd/nch369
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During X-ray therapeutic irradiation with energies above the threshold of (X,n) reactions in the structural materials of medical accelerators, a photoneutron fluence is generated. In Brazil, no measurements of neutron doses in radiotherapy rooms are being done yet, when licensing these equipment. Consequently, it is very important to obtain accurate analytical formulae and/or simulation of these dose rates, in order to estimate the increase in dose received by the patient and staff, as well as to correctly project the additional shielding for the treatment room. In this work, we present MCNP simulation of dosimetric quantities at the isocentre of some models of high-energy linear accelerators, and compare it with the values given by the manufacturers, finding good agreement between both.
引用
收藏
页码:101 / 103
页数:3
相关论文
共 50 条
  • [1] Evaluation of neutron dose in the maze of medical electron accelerators
    Carinou, E
    Kamenopoulou, V
    Stamatelatos, IE
    MEDICAL PHYSICS, 1999, 26 (12) : 2520 - 2525
  • [2] Characteristics of neutron equivalent dose around medical linear accelerators
    Wang, Y
    Evans, M
    Podgorsak, E
    MEDICAL PHYSICS, 2005, 32 (06) : 2020 - 2020
  • [3] THE NEUTRON DOSE EQUIVALENT AROUND HIGH ENERGY MEDICAL ELECTRON LINEAR ACCELERATORS
    Poje, Marina
    Ivkovic, Ana
    Jurkovic, Slaven
    Zauhar, Gordana
    Vukovic, Branko
    Radolic, Vanja
    Miklavcic, Igor
    Kaliman, Zoran
    Planinic, Josip
    Brkic, Hrvoje
    Faj, Dario
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2014, 29 (03): : 207 - 212
  • [4] DOSE MONITORING METHODS IN MEDICAL LINEAR ACCELERATORS
    SUTHERLAND, WH
    BRITISH JOURNAL OF RADIOLOGY, 1969, 42 (503): : 864 - +
  • [5] NEUTRON PHOTON DOSE MEASUREMENTS AT THE ENTRANCEWAYS TO LINEAR ACCELERATORS
    DEGUZMAN, A
    SCHULZ, RJ
    MEDICAL PHYSICS, 1987, 14 (04) : 712 - 712
  • [6] A study of neutron spectra from medical linear accelerators
    Facure, A
    Falcao, RC
    Silva, AX
    Crispim, VR
    Vitorelli, JC
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (01) : 69 - 72
  • [7] Accuracy of empirical formulas in evaluation of neutron dose equivalent inside the 60Co vaults reconstructed for medical linear accelerators
    Ivkovic, A.
    Faj, D.
    Galic, S.
    Karimi, A. H.
    Kasabasic, M.
    Brkic, H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (01): : 99 - 107
  • [8] ESTIMATION OF NEUTRON DOSE CONTRIBUTIONS TO PERSONNEL WORKING WITH HIGH-ENERGY MEDICAL LINEAR ACCELERATORS.
    Elezaj, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S237 - S237
  • [9] Evaluation of CdZnTe as neutron detector around medical accelerators
    Martin-Martin, A.
    Iniguez, M. P.
    Luke, P. N.
    Barquero, R.
    Lorente, A.
    Morchon, J.
    Gallego, E.
    Quincoces, G.
    Marti-Climent, J. M.
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 193 - 199
  • [10] Ambient dose equivalent meter for neutron dosimetry around medical accelerators
    Golnik, N.
    RECENT ADVANCES IN MECHATRONICS, 2007, : 206 - 210