Activity Evaluation Methodology for the Disposed Medical Linear Accelerators

被引:0
|
作者
Kwon, Na Hye [1 ,2 ]
Jang, Young Jae [3 ,4 ]
Kim, Kum Bae [4 ,5 ]
Yu, Ji Hyun [6 ]
Kim, Jinsung [1 ,2 ,7 ]
Kim, Dong Wook [1 ,2 ]
Choi, Sang Hyoun [4 ,5 ]
机构
[1] Yonsei Univ, Heavy Ion Therapy Res Inst, Yonsei Canc Ctr, Dept Radiat Oncol,Coll Med, Seoul 03722, South Korea
[2] Yonsei Univ, Med Phys & Biomed Engn Lab MPBEL, Coll Med, Seoul 03722, South Korea
[3] Korea Univ, Dept Accelerator Sci, Sejong 30015, South Korea
[4] Korea Inst Radiol & Med Sci, Res Team Radiol Phys & Engn, Seoul 01812, South Korea
[5] Korea Inst Radiol & Med Sci, Dept Radiat Oncol, Seoul 01812, South Korea
[6] Sae An Enertech Corp, R&D Inst, Daejeon 34016, South Korea
[7] Oncosoft Inc, Seoul 03787, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 01期
基金
新加坡国家研究基金会;
关键词
radioactive waste; disposed linear accelerators; radioactivation; in situ HPGe detectors; gamma spectroscopy;
D O I
10.3390/app13010528
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
For the medical linear accelerators (linac) that utilize more than 10 MV of photon energy, components inside the linac head become radioactivate during the 10-15-year operating cycle. Prior to disposal, radioactive waste must be evaluated for activity, and the same procedure should be followed for medical linacs. In the Republic of Korea, regulation and methodology for the radioactivity evaluation for the medical linac is not established yet. In this study, we employed gamma spectroscopy and a survey meter for evaluating the radioactivity of medical linac components. The components of the Siemens linac considered in this study were classified after decommissioning, and dose rates were measured to up to a 5 cm distance from the component surfaces by using a survey meter. Radionuclides from components were detected using an in situ HPGe detector. Based on the type of radionuclides and dose rate, we estimated the radioactivity of the components. We studied the feasibility of the methodology for disposing of radioactive components by using the in situ HPGe detector.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Nuclear reactions in linear medical accelerators and their exposure consequences
    Polaczek-Grelik, Kinga
    Karaczyn, Barbara
    Konefal, Adam
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (10) : 2332 - 2339
  • [22] Optimized Shielding Calculations for Medical Linear Accelerators (LINACs)
    Muhammad, W.
    Lee, S.
    Hussain, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3765 - 3765
  • [23] POSSIBLE MEDICAL AND INDUSTRIAL APPLICATION OF LINEAR ELECTRON ACCELERATORS
    BARBER, WC
    ELDREDGE, AL
    GINZTON, EL
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1953, 41 (03): : 422 - 422
  • [24] A beam-matching concept for medical linear accelerators
    Sjostrom, David
    Bjelkengren, Ulf
    Ottosson, Wiviann
    Behrens, Claus F.
    ACTA ONCOLOGICA, 2009, 48 (02) : 192 - 200
  • [25] ACTIVATION OF DOSIMETERS USED IN QA OF MEDICAL LINEAR ACCELERATORS
    Polaczek-Grelik, Kinga
    Nowacka, Magdalena
    Raczkowski, Maciej
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [26] WORKLOAD AND USE FACTOR OF MEDICAL LINEAR ACCELERATORS IN RADIOTHERAPY
    KRON, T
    ALDRICH, B
    JOVANOVIC, K
    HOWLETT, S
    HAMILTON, C
    HEALTH PHYSICS, 1995, 69 (06): : 971 - 975
  • [27] A study of neutron spectra from medical linear accelerators
    Facure, A
    Falcao, RC
    Silva, AX
    Crispim, VR
    Vitorelli, JC
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (01) : 69 - 72
  • [28] Evaluation of air photoactivation at linear accelerators for radiotherapy
    Tana, Luigi
    Ciolini, Riccardo
    Ciuffardi, Eva
    Romei, Chiara
    d'Errico, Francesco
    JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (02) : 239 - 248
  • [29] A methodology for computationally generating phase space files for Monte Carlo simulations applied to treatment plans for medical linear accelerators
    Oliver, S.
    Juste, B.
    Miro, R.
    Verdu, G.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 224
  • [30] Characteristics of neutron equivalent dose around medical linear accelerators
    Wang, Y
    Evans, M
    Podgorsak, E
    MEDICAL PHYSICS, 2005, 32 (06) : 2020 - 2020