Activity Evaluation Methodology for the Disposed Medical Linear Accelerators

被引:0
|
作者
Kwon, Na Hye [1 ,2 ]
Jang, Young Jae [3 ,4 ]
Kim, Kum Bae [4 ,5 ]
Yu, Ji Hyun [6 ]
Kim, Jinsung [1 ,2 ,7 ]
Kim, Dong Wook [1 ,2 ]
Choi, Sang Hyoun [4 ,5 ]
机构
[1] Yonsei Univ, Heavy Ion Therapy Res Inst, Yonsei Canc Ctr, Dept Radiat Oncol,Coll Med, Seoul 03722, South Korea
[2] Yonsei Univ, Med Phys & Biomed Engn Lab MPBEL, Coll Med, Seoul 03722, South Korea
[3] Korea Univ, Dept Accelerator Sci, Sejong 30015, South Korea
[4] Korea Inst Radiol & Med Sci, Res Team Radiol Phys & Engn, Seoul 01812, South Korea
[5] Korea Inst Radiol & Med Sci, Dept Radiat Oncol, Seoul 01812, South Korea
[6] Sae An Enertech Corp, R&D Inst, Daejeon 34016, South Korea
[7] Oncosoft Inc, Seoul 03787, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 01期
基金
新加坡国家研究基金会;
关键词
radioactive waste; disposed linear accelerators; radioactivation; in situ HPGe detectors; gamma spectroscopy;
D O I
10.3390/app13010528
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
For the medical linear accelerators (linac) that utilize more than 10 MV of photon energy, components inside the linac head become radioactivate during the 10-15-year operating cycle. Prior to disposal, radioactive waste must be evaluated for activity, and the same procedure should be followed for medical linacs. In the Republic of Korea, regulation and methodology for the radioactivity evaluation for the medical linac is not established yet. In this study, we employed gamma spectroscopy and a survey meter for evaluating the radioactivity of medical linac components. The components of the Siemens linac considered in this study were classified after decommissioning, and dose rates were measured to up to a 5 cm distance from the component surfaces by using a survey meter. Radionuclides from components were detected using an in situ HPGe detector. Based on the type of radionuclides and dose rate, we estimated the radioactivity of the components. We studied the feasibility of the methodology for disposing of radioactive components by using the in situ HPGe detector.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] REGULATIONS, STANDARDS AND GUIDELINES FOR USE OF MEDICAL ELECTRON LINEAR ACCELERATORS
    TURNER, AP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (08): : 1048 - 1048
  • [42] A Monte Carlo investigation of photoneutron shielding for medical linear accelerators
    Biggs, P
    Gierga, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1437 - 1437
  • [43] Beam matching evaluation of two similar linear accelerators
    Sistani, Soroush
    Babaeifar, Hamidreza
    Khoramian, Daryoush
    Arani, Mahmud Naraqi
    Sarvizadeh, Mostafa
    Kalantari, Faraz
    Ebrahimi, Ali
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (04) : 347 - 355
  • [44] Evaluation of CdZnTe as neutron detector around medical accelerators
    Martin-Martin, A.
    Iniguez, M. P.
    Luke, P. N.
    Barquero, R.
    Lorente, A.
    Morchon, J.
    Gallego, E.
    Quincoces, G.
    Marti-Climent, J. M.
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 193 - 199
  • [45] Evaluation of the photon monitor backscatter in medical electron accelerators
    Zrenner, M
    Krieger, H
    STRAHLENTHERAPIE UND ONKOLOGIE, 1999, 175 (10) : 515 - 523
  • [46] Evaluation of neutron dose in the maze of medical electron accelerators
    Carinou, E
    Kamenopoulou, V
    Stamatelatos, IE
    MEDICAL PHYSICS, 1999, 26 (12) : 2520 - 2525
  • [47] Evaluation of the effectiveness of steel for shielding photoneutrons produced in medical linear accelerators: A Monte Carlo particle transport study
    Moghaddasi, Leyla
    Colyer, Christopher
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 98 : 53 - 62
  • [48] LINEAR ACCELERATORS
    SLATER, JC
    ANNUAL REVIEW OF NUCLEAR SCIENCE, 1952, 1 : 199 - 206
  • [49] Linear accelerators
    Sidorin, A.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2007, 958 : 46 - 52
  • [50] LINEAR ACCELERATORS
    FRY, DW
    WALKINSHAW, W
    REPORTS ON PROGRESS IN PHYSICS, 1948, 12 : 102 - &