Estimating size specific dose estimate from computed tomography radiograph localizer with radiation risk assessment

被引:1
|
作者
Burton, Christiane Sarah [1 ]
Al-Ward, Shahad [2 ]
机构
[1] St Jude Childrens Res Hosp, Dept Diagnost Imaging, Memphis, TN 38105 USA
[2] St Jude Childrens Res Hosp, Dept Radiat Oncol, Memphis, TN USA
来源
关键词
CT; localizer; SSDE; water-equivalent diameter; BODY CT; ABDOMEN;
D O I
10.1002/acm2.13989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundQuantifying radiation burden is necessary for optimizing imaging protocols. The normalized dose coefficient (NDC) is determined from the water-equivalent diameter (WED) and is used to scale the CTDIvol based on body habitus to determine the size specific dose estimate (SSDE). In this study we determine the SSDE prior to the CT scan and how sensitive the SSDE from WED is to the lifetime attributable risk (LAR) from BEIR VII. MethodFor calibration, phantom images are used to relate the mean pixel values along a profile (PPV over bar $\overline {{\rm{PPV}}} $) of the CT localizer to the water-equivalent area (A(W)) of the CT axial scan at the same z-location. Images of the CTDIvol phantoms (32 cm, 16 cm, and similar to 1 cm) and ACR phantom (Gammex 464) were acquired on four scanners. The relationship between the A(W) and PPV over bar $\overline {{\rm{PPV}}} $ was used to calculate the WED from the CT localizer for patient scans. A total of 790 CT examinations of the chest and abdominopelvic regions were used in this study. The effective diameter (ED) was calculated from the CT localizer. The LAR was calculated based on the patient chest and abdomen using the National Cancer Institute Dosimetry System for Computed Tomography (NCICT). The radiation sensitivity index (RSI) and risk differentiability index (RDI) were calculated for SSDE and CTDIvol. ResultsThe WED from CT localizers and CT axials scans show good correlation (R-2 = 0.96) with the maximum percentage difference being 13.45%. The NDC from WED correlates poorly with LAR for lungs (R-2 = 0.18) and stomach (R-2 = 0.19), however that is the best correlation. ConclusionThe SSDE can be determined within 20% as recommended by the report of AAPM TG 220. The CTDIvol and SSDE are not good surrogates for radiation risk, however the sensitivity for SSDE improves when using WED instead of ED.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A simple manual method to estimate water-equivalent diameter for calculating size-specific dose estimate in chest computed tomography
    Mihailidis, Dimitris
    Tsapaki, Virginia
    Tomara, Pelagia
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1117):
  • [32] Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria
    Olaniyan T.A.
    Aborisade C.A.
    Balogun F.A.
    Ogunsina S.A.
    Saidu A.
    Ibrahim M.B.
    Iranian Journal of Medical Physics, 2019, 16 (01) : 85 - 90
  • [33] ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY (vol 178, pg 8, 2018)
    Boos, Johannes
    Kropil, Patric
    Bethge, Oliver Th
    Aissa, Joel
    Schleich, Christoph
    Sawicki, Lino Morris
    Heinzler, Niklas
    Antoch, Gerald
    Thomas, Christoph
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (03) : 343 - 343
  • [34] Size specific dose estimate (SSDE) for estimating patient dose from CT in myocardial perfusion SPECT/CT
    Rajaraman, V.
    Ponnusamy, M.
    Halanaik, D.
    Pandit, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S735 - S735
  • [35] Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Abdelrahman, Mostafa
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [36] EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED-TOMOGRAPHY OF THE MAXILLOFACIAL COMPLEX
    FREDERIKSEN, NL
    BENSON, BW
    SOKOLOWSKI, TW
    DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (01) : 55 - 58
  • [37] Radiation Dose from Diagnostic Computed Tomography in Saskatchewan
    Leswick, David A.
    Syed, Nida S.
    Dumaine, Chance S.
    Lim, Hyun J.
    Fladeland, Derek A.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2009, 60 (02): : 71 - 78
  • [38] Radiation risk to children from computed tomography
    Brody, Alan S.
    Frush, Donald P.
    Huda, Walter
    Brent, Robert L.
    PEDIATRICS, 2007, 120 (03) : 677 - 682
  • [39] Radiation risk to children from computed tomography
    Kirpalani, Haresh
    Nahmias, Claude