Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria

被引:0
|
作者
Olaniyan T.A. [1 ]
Aborisade C.A. [1 ]
Balogun F.A. [2 ]
Ogunsina S.A. [1 ]
Saidu A. [3 ]
Ibrahim M.B. [1 ]
机构
[1] Department of Physics, Faculty of Sciences, Obafemi Awolowo University, Ile-Ife
[2] Centre for Energy Research and Development, Obafemi Awolowo University, Ile-Ife
[3] Department of Physics, Faculty of Sciences, Usmanu Danfodiyo University, Sokoto
关键词
BEIR VII model; Computed tomography (CT); Eeffective dose; Radiation protection; Risk assessment;
D O I
10.22038/ijmp.2018.23516.1234
中图分类号
学科分类号
摘要
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT examinations in Ondo, Nigeria. Material and Methods: The study was conducted on 160 patients undergoing eight most common types of CT examinations performed at the center, from December 5, 2015 to February 28, 2016. Body mass index (BMI) was calculated for each patient using demographic data, PSD was determined and estimation of the lifetime attributable risk (LAR) of cancer was accomplished using the Biologic Effects of Ionizing Radiation VII (2006) report phase 2 models. Results: From the results, radiation doses varied significantly within and between the types of CT examinations. The mean ED was 5.88±3.75 mSv in a range of 0.78-19.00 mSv. The mean PSD was 0.274±0.229 mSv/kgm -2 in a range of 0.024-1.555 mSv/kgm -2 and the mean LAR of cancer incidence was 0.04861±0.03996 Sv -1 in a range of 0.00004-0.21942 Sv -1 . Conclusion: ED and PSD varied within and across the CT examinations. In this regard, the coefficients of variation of ED for abdominal, cranial, craniocervical, abdomen/pelvis, thoracic, thoracoabdominal, cervical spine, and pelvis were 5.7%, 6.6%, 3.9%, 8.9%, 3.7%, 6.0%, 44.7%, and 19.2%, respectively. Accordingly, the coefficients of variation of PSD were 9.0%, 7.9%, 7.0%, 10.1%, 5.6%, 23.8%, 47.7%, and 14.2%. © 2019, Mashhad University of Medical Sciences.
引用
收藏
页码:85 / 90
页数:5
相关论文
共 50 条
  • [1] Diagnostic reference level of computed tomography examinations and need for dose optimization in Ondo State, Nigeria
    Oyedokun O.S.
    Arogunjo A.M.
    Fatukasi J.I.
    Egberongbe A.A.
    Oyedokun, Oluwakayode Samuel (osoyedokun@futa.edu.ng), 1600, Mashhad University of Medical Sciences (17): : 266 - 272
  • [2] Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    RADIOLOGY, 2011, 259 (03) : 862 - 874
  • [3] Radiation Dose Associated With Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of Cancer
    Smith-Bindman, Rebecca
    Lipson, Jafi
    Marcus, Ralph
    Kim, Kwang-Pyo
    Mahesh, Mahadevappa
    Gould, Robert
    de Gonzalez, Amy Berrington
    Miglioretti, Diana L.
    ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) : 2078 - 2086
  • [4] Patient dose considerations in computed tomography examinations
    Tsalafoutas, Ioannis A.
    Koukourakis, Georgios V.
    WORLD JOURNAL OF RADIOLOGY, 2010, 2 (07): : 262 - 268
  • [5] Effective radiation dose and radiogenic cancer risk during contrast enhanced abdominal computed tomography examinations
    Sulieman, A.
    Tamam, N.
    Elnour, Abdelrahman
    Alkhorayef, M.
    Babikir, E.
    Al-Mohammed, Huda I.
    Abuhadi, N.
    Khandaker, Mayeen Uddin
    Bradley, David A.
    Radiation Physics and Chemistry, 2022, 200
  • [6] Effective radiation dose and radiogenic cancer risk during contrast enhanced abdominal computed tomography examinations
    Sulieman, A.
    Tamam, N.
    Elnour, Abdelrahman
    Alkhorayef, M.
    Babikir, E.
    Al-Mohammed, Huda I.
    Abuhadi, N.
    Khandaker, Mayeen Uddin
    Bradley, David A.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [7] Patient-specific organ and effective dose estimates in pediatric oncology computed tomography
    Gao, Yiming
    Quinn, Brian
    Pandit-Taskar, Neeta
    Behr, Gerald
    Mahmood, Usman
    Long, Daniel
    Xu, X. George
    St.Germain, Jean
    Dauer, Lawrence T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 146 - 155
  • [8] PATIENT-SPECIFIC DOSE ESTIMATES IN DYNAMIC COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION EXAMINATION
    Sundell, V-M
    Kortesniemil, M.
    Siiskonen, T.
    Kosunen, A.
    Rosendahl, S.
    Bueermann, L.
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (01) : 24 - 36
  • [9] Triple-Rule-Out Computed Tomography Angiography With 256-Slice Computed Tomography Scanners Patient-Specific Assessment of Radiation Burden and Associated Cancer Risk
    Perisinakis, Kostas
    Seimenis, Ioannis
    Tzedakis, Antonis
    Papadakis, Antonios E.
    Damilakis, John
    INVESTIGATIVE RADIOLOGY, 2012, 47 (02) : 109 - 115
  • [10] From patient-informed to patient-specific organ dose estimation in clinical computed tomography
    Fu, Wanyi
    Segars, William P.
    Abadi, Ehsan
    Sharma, Shobhit
    Kapadia, Anuj J.
    Samei, Ehsan
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573