Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT

被引:93
|
作者
Li, Xiang [1 ]
Samei, Ehsan [1 ]
Segars, W. Paul [1 ]
Sturgeon, Gregory M. [1 ]
Colsher, James G. [1 ]
Frush, Donald P. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27705 USA
基金
美国国家卫生研究院;
关键词
COMPUTED-TOMOGRAPHY; LENGTH PRODUCT; IMAGE QUALITY; ORGAN; MDCT; REDUCTION; SIZE; AGE;
D O I
10.1148/radiol.11101900
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. Materials and Methods: The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0-16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDIvol) or dose-length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Results: Organ dose normalized by tube current-time product or CTDIvol decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current-time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current-time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (< 10% variation). Conclusion: The correlations of dose and risk with patient size and age can be used to estimate patient-specific dose and risk. They can further guide the design and optimization of pediatric chest CT protocols. (C) RSNA, 2011
引用
收藏
页码:862 / 874
页数:13
相关论文
共 50 条
  • [1] Patient-Specific Radiation Dose and Cancer Risk Estimation in Pediatric Chest CT: A Study in 30 Patients
    Lia, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [2] Patient-specific dose estimation for pediatric chest CT
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5821 - 5828
  • [3] Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
    Susan D. Kost
    Nicholas D. Fraser
    Diana E. Carver
    David R. Pickens
    Ronald R. Price
    Marta Hernanz-Schulman
    Michael G. Stabin
    [J]. Pediatric Radiology, 2015, 45 : 1771 - 1780
  • [4] Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
    Kost, Susan D.
    Fraser, Nicholas D.
    Carver, Diana E.
    Pickens, David R.
    Price, Ronald R.
    Hernanz-Schulman, Marta
    Stabin, Michael G.
    [J]. PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1771 - 1780
  • [5] Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization
    Bacher, K
    Bogaert, E
    Lapere, R
    De Wolf, D
    Thierens, H
    [J]. CIRCULATION, 2005, 111 (01) : 83 - 89
  • [6] Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Toncheva, Greta
    Yoshizumi, Terry T.
    Frush, Donald P.
    [J]. MEDICAL PHYSICS, 2011, 38 (01) : 408 - 419
  • [7] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Franck, Caro
    Vandevoorde, Charlot
    Goethals, Ingeborg
    Smeets, Peter
    Achten, Eric
    Verstraete, Koenraad
    Thierens, Hubert
    Bacher, Klaus
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (08) : 2646 - 2655
  • [8] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Caro Franck
    Charlot Vandevoorde
    Ingeborg Goethals
    Peter Smeets
    Eric Achten
    Koenraad Verstraete
    Hubert Thierens
    Klaus Bacher
    [J]. European Radiology, 2016, 26 : 2646 - 2655
  • [9] Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria
    Olaniyan T.A.
    Aborisade C.A.
    Balogun F.A.
    Ogunsina S.A.
    Saidu A.
    Ibrahim M.B.
    [J]. Iranian Journal of Medical Physics, 2019, 16 (01) : 85 - 90
  • [10] Patient-specific radiation dose for Chinese pediatric patients undergoing whole-body PET/CT examinations
    Jia, Haoran
    Xue, Mengjia
    Li, Xianru
    Zhuang, Mingzan
    Xie, Tianwu
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (12):