Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria

被引:0
|
作者
Olaniyan T.A. [1 ]
Aborisade C.A. [1 ]
Balogun F.A. [2 ]
Ogunsina S.A. [1 ]
Saidu A. [3 ]
Ibrahim M.B. [1 ]
机构
[1] Department of Physics, Faculty of Sciences, Obafemi Awolowo University, Ile-Ife
[2] Centre for Energy Research and Development, Obafemi Awolowo University, Ile-Ife
[3] Department of Physics, Faculty of Sciences, Usmanu Danfodiyo University, Sokoto
关键词
BEIR VII model; Computed tomography (CT); Eeffective dose; Radiation protection; Risk assessment;
D O I
10.22038/ijmp.2018.23516.1234
中图分类号
学科分类号
摘要
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT examinations in Ondo, Nigeria. Material and Methods: The study was conducted on 160 patients undergoing eight most common types of CT examinations performed at the center, from December 5, 2015 to February 28, 2016. Body mass index (BMI) was calculated for each patient using demographic data, PSD was determined and estimation of the lifetime attributable risk (LAR) of cancer was accomplished using the Biologic Effects of Ionizing Radiation VII (2006) report phase 2 models. Results: From the results, radiation doses varied significantly within and between the types of CT examinations. The mean ED was 5.88±3.75 mSv in a range of 0.78-19.00 mSv. The mean PSD was 0.274±0.229 mSv/kgm -2 in a range of 0.024-1.555 mSv/kgm -2 and the mean LAR of cancer incidence was 0.04861±0.03996 Sv -1 in a range of 0.00004-0.21942 Sv -1 . Conclusion: ED and PSD varied within and across the CT examinations. In this regard, the coefficients of variation of ED for abdominal, cranial, craniocervical, abdomen/pelvis, thoracic, thoracoabdominal, cervical spine, and pelvis were 5.7%, 6.6%, 3.9%, 8.9%, 3.7%, 6.0%, 44.7%, and 19.2%, respectively. Accordingly, the coefficients of variation of PSD were 9.0%, 7.9%, 7.0%, 10.1%, 5.6%, 23.8%, 47.7%, and 14.2%. © 2019, Mashhad University of Medical Sciences.
引用
收藏
页码:85 / 90
页数:5
相关论文
共 50 条
  • [31] Radiation dose of chaperones during common pediatric computed tomography examinations
    Overhoff, Daniel
    Weis, Meike
    Riffel, Philipp
    Sudarski, Sonja
    Froelich, Matthias F.
    Fries, Peter
    Schoenberg, Stefan
    Gawlitza, Joshua
    [J]. PEDIATRIC RADIOLOGY, 2020, 50 (08) : 1078 - 1082
  • [32] Radiation dose of chaperones during common pediatric computed tomography examinations
    Daniel Overhoff
    Meike Weis
    Philipp Riffel
    Sonja Sudarski
    Matthias F. Froelich
    Peter Fries
    Stefan Schönberg
    Joshua Gawlitza
    [J]. Pediatric Radiology, 2020, 50 : 1078 - 1082
  • [33] Radiation dose of head and abdomen-pelvis computed tomography examinations using size-specific dose estimate
    Ahmadifard, M.
    Bakhshandeh, M.
    Mohammadbeigi, A.
    Khoshgard, K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 185 - 189
  • [34] Physical dose quantities in computed tomography - How effective for describing the patient dose and the radiation risk?
    Hidajat, N
    Wolf, M
    Felix, R
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 171 - 174
  • [35] Patient effective dose estimation for routine computed tomography examinations in Iran
    Deevband, M. R.
    Ghorbani, M.
    Eshraghi, A.
    Salimi, Y.
    Saeedzadeh, E.
    Kardan, M. R.
    Sadeghi, S.
    Divband, D.
    Ahmadi, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (01): : 63 - 73
  • [36] Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography
    Paul Deak
    Marcel van Straten
    Paul C. Shrimpton
    Maria Zankl
    Willi A. Kalender
    [J]. European Radiology, 2008, 18 : 759 - 772
  • [37] Multi-organ segmentation in clinical computed tomography for patient-specific image quality and dose metrology
    Fu, Wanyi
    Sharma, Shobhit
    Smith, Taylor
    Hou, Rui
    Abadi, Ehsan
    Selvakumaran, Vignesh
    Tang, Ruixiang
    Lo, Joseph Y.
    Segars, W. Paul
    Kapadia, Anuj J.
    Solomon, Justin B.
    Rubin, Geoffrey D.
    Samei, Ehsan
    [J]. MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [38] Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography
    Deak, Paul
    van Straten, Marcel
    Shrimpton, Paul C.
    Zankl, Maria
    Kalender, Willi A.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (04) : 759 - 772
  • [39] Computed tomography radiation doses for common computed tomography examinations: a nationwide dose survey in United Arab Emirates
    Abuzaid, Mohamed M.
    Elshami, Wiam
    Tekin, Huseyin Ozan
    Ghonim, Hatem
    Shawki, Mona
    Salama, Dina H.
    [J]. INSIGHTS INTO IMAGING, 2020, 11 (01)
  • [40] Computed tomography radiation doses for common computed tomography examinations: a nationwide dose survey in United Arab Emirates
    Mohamed M. Abuzaid
    Wiam Elshami
    Huseyin Ozan Tekin
    Hatem Ghonim
    Mona Shawki
    Dina H. Salama
    [J]. Insights into Imaging, 11