Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence

被引:6
|
作者
Ferrero, Andrea [1 ]
Powell, Garret M. [1 ]
Adaaquah, Dennis K. [1 ]
Rajendran, Kishore [1 ]
Thorne, Jamison E. [1 ]
Krych, Aaron J. [2 ]
Horst, Kelly K. [1 ]
McCollough, Cynthia H. [1 ]
Baffour, Francis I. [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 1st St SW, Rochester, MN 55902 USA
[2] Mayo Clin, Dept Orthoped Surg & Sports Med, Rochester, MN USA
关键词
Photon-counting CT; Femoroacetabular impingement; Radiation dose reduction; Pelvis CT; COMPUTED-TOMOGRAPHY; HIP ARTHROSCOPY; COMMON;
D O I
10.1007/s00256-023-04325-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective The feasibility of low-dose photon-counting detector (PCD) CT to measure alpha and acetabular version angles of femoroacetabular impingement (FAI). Material and methods FAI patients undergoing an energy-integrating detector (EID) CT underwent an IRB-approved prospective ultra-high-resolution (UHR) PCD-CT between 5/2021 and 12/2021. PCD-CT was dose-matched to the EID-CT or acquired at 50% dose. Simulated 50% dose EID-CT images were generated. Two radiologists evaluated randomized EID-CT and PCD-CT images and measured alpha and acetabular version angles on axial image slices. Image quality (noise, artifacts, and visualization of cortex) and confidence in non-FAI pathology were rated on a 4-point scale (3 = adequate). Preference tests of standard dose PCD-CT, 50% dose PCD-CT, and 50% dose EID-CT relative to standard dose EID-CT were performed using Wilcoxon Rank test. Results 20 patients underwent standard dose EID-CT (similar to CTDIvol, 4.5 mGy); 10 patients, standard dose PCD-CT (4.0 mGy); 10 patients, 50% PCD-CT (2.6 mGy). Standard dose EID-CT images were scored as adequate for diagnostic task in all categories (range 2.8-3.0). Standard dose PCD-CT images scored higher than the reference in all categories (range 3.5-4, p < 0.0033). Half-dose PCD-CT images also scored higher for noise and cortex visualization (p < 0.0033) and equivalent for artifacts and visualization of non-FAI pathology. Finally, simulated 50% EID-CT images scored lower in all categories (range 1.8-2.4, p < 0.0033). Conclusions Dose-matched PCD-CT is superior to EID-CT for alpha angle and acetabular version measurement in the work up of FAI. UHR-PCD-CT enables 50% radiation dose reduction compared to EID while remaining adequate for the imaging task.
引用
收藏
页码:1651 / 1659
页数:9
相关论文
共 50 条
  • [31] Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes: a dynamic phantom study
    Magdalena M. Dobrolinska
    Niels R. van der Werf
    Judith van der Bie
    Joël de Groen
    Marcel Dijkshoorn
    Ronald Booij
    Ricardo P. J. Budde
    Marcel J. W. Greuter
    Marcel van Straten
    European Radiology, 2023, 33 : 4668 - 4675
  • [32] Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT
    El-Ali, Alexander M.
    Strubel, Naomi
    Pinkney, Lynne
    Xue, Christine
    Dane, Bari
    Lala, Shailee V.
    PEDIATRIC RADIOLOGY, 2024, 54 (12) : 1984 - 1995
  • [33] Photon-counting detector CT allows significant reduction in radiation dose while maintaining image quality and noise on non-contrast chest CT
    Donuru, Achala
    Araki, Tetsuro
    Dako, Farouk
    Dave, Jaydev K.
    Perez, Raul Porto
    Xu, Dongming
    Nachiappan, Arun C.
    Barbosa Jr, Eduardo Mortani
    Noel, Peter
    Litt, Harold
    Knollman, Friedrich
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 11
  • [34] Improved coronary calcium detection and quantification with low-dose full field-of-view photon-counting CT: a phantom study
    N. R. van der Werf
    P. A. Rodesch
    S. Si-Mohamed
    R. W. van Hamersvelt
    M. J. W. Greuter
    T. Leiner
    L. Boussel
    M. J. Willemink
    P. Douek
    European Radiology, 2022, 32 : 3447 - 3457
  • [35] Low-dose photon-counting CT with penalized-likelihood basis-image reconstruction: image quality evaluation
    Persson, Mats U.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [36] Improved coronary calcium detection and quantification with low-dose full field-of-view photon-counting CT: a phantom study
    van der Werf, N. R.
    Rodesch, P. A.
    Si-Mohamed, S.
    van Hamersvelt, R. W.
    Greuter, M. J. W.
    Leiner, T.
    Boussel, L.
    Willemink, M. J.
    Douek, P.
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 3447 - 3457
  • [37] Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography
    Ayx, Isabelle
    Lichti, Lena
    Buettner, Sylvia
    Papavassiliu, Theano
    Sopova, Kateryna
    Schoenberg, Stefan O.
    Kuru, Mustafa
    Marschner, Constantin Arndt
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183
  • [38] Photon-counting detector CT: improving interstitial lung disease classification using ultra-high resolution at a fraction of the radiation dose?
    Kishore Rajendran
    Chi Wan Koo
    European Radiology, 2023, 33 : 5526 - 5527
  • [39] Photon-counting detector CT: improving interstitial lung disease classification using ultra-high resolution at a fraction of the radiation dose?
    Rajendran, Kishore
    Koo, Chi Wan
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5526 - 5527
  • [40] A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT
    Kammerling, Nina
    Tesselaar, Erik
    Booij, Ronald
    Fornander, Lotta
    Persson, Anders
    Farnebo, Simon
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 173