Photon-counting detector CT allows significant reduction in radiation dose while maintaining image quality and noise on non-contrast chest CT

被引:4
|
作者
Donuru, Achala [1 ,3 ]
Araki, Tetsuro [1 ,3 ]
Dako, Farouk [1 ,3 ]
Dave, Jaydev K. [2 ]
Perez, Raul Porto [1 ,3 ]
Xu, Dongming [1 ,3 ]
Nachiappan, Arun C. [1 ,3 ]
Barbosa Jr, Eduardo Mortani [1 ,3 ]
Noel, Peter [1 ,3 ]
Litt, Harold [1 ,3 ]
Knollman, Friedrich [1 ,3 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[3] 3400 Spruce St, Philadelphia, PA 19104 USA
关键词
Photon counting computed tomography; Energy integrating detectors; Virtual monoenergetic imaging; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.ejro.2023.100538
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol.Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner.Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p < 0.001). The median DLP with the PCD-CT was 182.0 mGy.cm and EID system was 262.60 mGy.cm (p < 0.001). The contrast to noise ratio (CNR) was superior on the PCD-CT system 59.2 compared to the EID-CT 53.3; (p < 0.001). Kappa statistic showed that there was poor agreement between the readers over the image quality from the PCD and EID scanners (kappa = 0.19; 95 % CI: 0.12 - 0.27; p < 0.001). Chi-square analysis revealed that 3 out of 5 readers showed a significant preference for images from the PCDCT (p <= 0.012). There was no significant difference in the preferences of two readers between EID-CT and PCD-CT images.Conclusion: The first clinical PCD-CT system allows a significant reduction in radiation exposure while maintaining image quality and image noise using a standardized non-contrast chest CT protocol.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT
    El-Ali, Alexander M.
    Strubel, Naomi
    Pinkney, Lynne
    Xue, Christine
    Dane, Bari
    Lala, Shailee V.
    PEDIATRIC RADIOLOGY, 2024, 54 (12) : 1984 - 1995
  • [2] Potential dose reduction and image quality improvement in chest CT with a photon-counting CT compared to a new dual-source CT
    Greffier, Joel
    Dabli, Djamel
    Faby, Sebastian
    Pastor, Maxime
    de Oliveira, Fabien
    Croisille, Cedric
    Erath, Julien
    Beregi, Jean-Paul
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 127
  • [3] Comparison of Image Quality and Radiation Dose in Pediatric Temporal Bone CT Using Photon-Counting Detector CT and Energy-Integrating Detector CT
    Lee, Jeong Sub
    Kim, John
    Bapuraj, Jayapalli R.
    Srinivasan, Ashok
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (09) : 1322 - 1326
  • [4] Comparison of Radiation Dose and Image Quality of Pediatric High-Resolution Chest CT Between Photon-Counting Detector CT and Energy-Integrated Detector CT: A Matched Study
    Siegel, Marilyn J.
    Bugenhagen, Scott M.
    Sanchez, Adrian
    Kim, Stacy
    Abadia, Andres
    Ramirez-Giraldo, Juan C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 221 (03) : 363 - 371
  • [5] The reliability of virtual non-contrast reconstructions of photon-counting detector CT scans in assessing abdominal organs
    Dudas, Ibolyka
    Schultz, Leona
    Benke, Marton
    Szucs, Akos
    Kaposi, Pal Novak
    Szijarto, Attila
    Maurovich-Horvat, Pal
    Budai, Bettina Katalin
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [6] Influence of Threshold Calibration On CT Image Quality of a Photon-Counting Detector
    Rodesch, P.
    Richtsmeier, D.
    Zalavari, L.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E174 - E174
  • [7] Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT
    Higashigaito, Kai
    Euler, Andre
    Eberhard, Matthias
    Flohr, Thomas G.
    Schmidt, Bernhard
    Alkadhi, Hatem
    ACADEMIC RADIOLOGY, 2022, 29 (05) : 689 - 697
  • [8] Reducing contrast media and radiation dose in CT angiography at low tube voltage: animal study with photon-counting detector CT
    Konstantin Klambauer
    Thomas Flohr
    Lukas Jakob Moser
    Victor Mergen
    Matthias Eberhard
    Andreas Prokein
    Hatem Alkadhi
    Hubertus Pietsch
    Gregor Jost
    European Radiology Experimental, 9 (1)
  • [9] Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction
    Pannenbecker, Pauline
    Huflage, Henner
    Grunz, Jan-Peter
    Gruschwitz, Philipp
    Patzer, Theresa S.
    Weng, Andreas M.
    Heidenreich, Julius F.
    Bley, Thorsten A.
    Petritsch, Bernhard
    EUROPEAN RADIOLOGY, 2023, 33 (11) : 7830 - 7839
  • [10] Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction
    Pauline Pannenbecker
    Henner Huflage
    Jan-Peter Grunz
    Philipp Gruschwitz
    Theresa S. Patzer
    Andreas M. Weng
    Julius F. Heidenreich
    Thorsten A. Bley
    Bernhard Petritsch
    European Radiology, 2023, 33 : 7830 - 7839