Photon-counting detector CT allows significant reduction in radiation dose while maintaining image quality and noise on non-contrast chest CT

被引:4
|
作者
Donuru, Achala [1 ,3 ]
Araki, Tetsuro [1 ,3 ]
Dako, Farouk [1 ,3 ]
Dave, Jaydev K. [2 ]
Perez, Raul Porto [1 ,3 ]
Xu, Dongming [1 ,3 ]
Nachiappan, Arun C. [1 ,3 ]
Barbosa Jr, Eduardo Mortani [1 ,3 ]
Noel, Peter [1 ,3 ]
Litt, Harold [1 ,3 ]
Knollman, Friedrich [1 ,3 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[3] 3400 Spruce St, Philadelphia, PA 19104 USA
关键词
Photon counting computed tomography; Energy integrating detectors; Virtual monoenergetic imaging; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.ejro.2023.100538
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol.Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner.Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p < 0.001). The median DLP with the PCD-CT was 182.0 mGy.cm and EID system was 262.60 mGy.cm (p < 0.001). The contrast to noise ratio (CNR) was superior on the PCD-CT system 59.2 compared to the EID-CT 53.3; (p < 0.001). Kappa statistic showed that there was poor agreement between the readers over the image quality from the PCD and EID scanners (kappa = 0.19; 95 % CI: 0.12 - 0.27; p < 0.001). Chi-square analysis revealed that 3 out of 5 readers showed a significant preference for images from the PCDCT (p <= 0.012). There was no significant difference in the preferences of two readers between EID-CT and PCD-CT images.Conclusion: The first clinical PCD-CT system allows a significant reduction in radiation exposure while maintaining image quality and image noise using a standardized non-contrast chest CT protocol.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma
    Rau, Alexander
    Neubauer, Jakob
    Taleb, Laetitia
    Stein, Thomas
    Schuermann, Till
    Rau, Stephan
    Faby, Sebastian
    Wenger, Sina
    Engelhardt, Monika
    Bamberg, Fabian
    Weiss, Jakob
    KOREAN JOURNAL OF RADIOLOGY, 2023, 24 (10) : 1006 - 1016
  • [42] Radiation Dose Reduction in Contrast-Enhanced Abdominal CT: Comparison of Photon-Counting Detector CT with 2nd Generation Dual-Source Dual-Energy CT in an oncologic cohort
    Wrazidlo, Robin
    Walder, Lukas
    Estler, Arne
    Gutjahr, Ralf
    Schmidt, Bernhard
    Faby, Sebastian
    Fritz, Jan
    Nikolaou, Konstantin
    Horger, Marius
    Hagen, Florian
    ACADEMIC RADIOLOGY, 2023, 30 (05) : 855 - 862
  • [43] Radiation dose reduction using spectral shaping in pediatric non-contrast sinus CT
    Zhou, Wei
    Malave, Maricarmen Nazario
    Maloney, John A.
    White, Christina
    Weinman, Jason P.
    Huo, Donglai
    Neuberger, Ilana
    PEDIATRIC RADIOLOGY, 2023, 53 (10) : 2069 - 2078
  • [44] Radiation dose reduction using spectral shaping in pediatric non-contrast sinus CT
    Wei Zhou
    Maricarmen Nazario Malave
    John A. Maloney
    Christina White
    Jason P. Weinman
    Donglai Huo
    Ilana Neuberger
    Pediatric Radiology, 2023, 53 : 2069 - 2078
  • [45] Commentary: There is more value in photon counting detector CT for children than in radiation dose reduction
    Horst, Kelly K.
    Yu, Lifeng
    PEDIATRIC RADIOLOGY, 2024, 54 (12) : 1996 - 1997
  • [46] Dose Savings and Image Quality in Dual-Energy Non-Contrast CT Scans
    Anthony, G.
    Liang, Y.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [47] Accuracy of Nodule Volume and Airway Wall Thickness Measurement Using Low-Dose Chest CT on a Photon-Counting Detector CT Scanner
    Dunning, Chelsea A. S.
    Marsh, Jeffrey F., Jr.
    Winfree, Timothy
    Rajendran, Kishore
    Leng, Shuai
    Levin, David L.
    Johnson, Tucker F.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    INVESTIGATIVE RADIOLOGY, 2023, 58 (04) : 283 - 292
  • [48] Photon-Counting Detector CT for Temporal Bone Imaging: Up to Three Times the Resolution at Half the Radiation Dose
    Macielak, Robert J.
    Benson, John C.
    Lane, John I.
    Carlson, Matthew L.
    Leng, Shuai
    OTOLOGY & NEUROTOLOGY, 2022, 43 (10) : E1205 - E1207
  • [49] Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter
    Rajendran, Kishore
    Voss, Benjamin A.
    Zhou, Wei
    Tao, Shengzhen
    DeLone, David R.
    Lane, John, I
    Weaver, Jayse M.
    Carlson, Matthew L.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2020, 55 (02) : 91 - 100
  • [50] Assessment of visibility of bone structures in the wrist using normal and half of the radiation dose with photon-counting detector CT
    Booij, Ronald
    Kammerling, Nina F.
    Oei, Edwin H. G.
    Persson, Anders
    Tesselaar, Erik
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 159