Commentary: There is more value in photon counting detector CT for children than in radiation dose reduction

被引:0
|
作者
Horst, Kelly K. [1 ]
Yu, Lifeng [1 ]
机构
[1] Mayo Clin, Rochester, NY 55902 USA
关键词
D O I
10.1007/s00247-024-06084-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
引用
收藏
页码:1996 / 1997
页数:2
相关论文
共 50 条
  • [1] Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT
    Rajendran, Kishore
    Baffour, Francis
    Powell, Garret
    Glazebrook, Katrina
    Thorne, Jamison
    Larson, Nicholas
    Leng, Shuai
    McCollough, Cynthia
    Fletcher, Joel
    SKELETAL RADIOLOGY, 2023, 52 (01) : 23 - 29
  • [2] Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT
    Kishore Rajendran
    Francis Baffour
    Garret Powell
    Katrina Glazebrook
    Jamison Thorne
    Nicholas Larson
    Shuai Leng
    Cynthia McCollough
    Joel Fletcher
    Skeletal Radiology, 2023, 52 : 23 - 29
  • [3] Photon-Counting Detector CT With Quantum Iterative Reconstruction Impact on Liver Lesion Detection and Radiation Dose Reduction
    Racine, Damien
    Mergen, Victor
    Viry, Anais
    Eberhard, Matthias
    Becce, Fabio
    Rotzinger, David C.
    Alkadhi, Hatem
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2023, 58 (04) : 245 - 252
  • [4] Potential of Photon-Counting Detector CT for Radiation Dose Reduction for the Assessment of Interstitial Lung Disease in Patients With Systemic Sclerosis
    Jungblut, Lisa
    Euler, Andre
    von Spiczak, Jochen
    Sartoretti, Thomas
    Mergen, Victor
    Englmaier, Vanessa
    Landsmann, Anna
    Mihai, Carmen-Marina
    Distler, Oliver
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Martini, Katharina
    INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 773 - 779
  • [5] Photon- Counting Detector CT Versus Energy- Integrating Detector CT of the Lumbar Spine: Comparison of Radiation Dose and Image Quality
    Marth, Adrian A.
    Marcus, Roy P.
    Feuerriegel, Georg C.
    Nanz, Daniel
    Sutter, Reto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (01)
  • [6] Photon-counting detector CT allows significant reduction in radiation dose while maintaining image quality and noise on non-contrast chest CT
    Donuru, Achala
    Araki, Tetsuro
    Dako, Farouk
    Dave, Jaydev K.
    Perez, Raul Porto
    Xu, Dongming
    Nachiappan, Arun C.
    Barbosa Jr, Eduardo Mortani
    Noel, Peter
    Litt, Harold
    Knollman, Friedrich
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 11
  • [7] Photon-Counting Detector CT
    Marth, Adrian A.
    Goller, Sophia S.
    Kajdi, Georg W.
    Marcus, Roy P.
    Sutter, Reto
    INVESTIGATIVE RADIOLOGY, 2024, 59 (08) : 545 - 553
  • [8] Impact of radiation dose level on CT number accuracy in photon counting CT
    Zhang, Ran
    Cruz-Bastida, Juan P.
    Gomez-Cardona, Daniel
    Hayes, John
    Li, Ke
    Chen, Guang-Hong
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [9] Comparison of Image Quality and Radiation Dose in Pediatric Temporal Bone CT Using Photon-Counting Detector CT and Energy-Integrating Detector CT
    Lee, Jeong Sub
    Kim, John
    Bapuraj, Jayapalli R.
    Srinivasan, Ashok
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (09) : 1322 - 1326
  • [10] Lesion Detectability and Radiation Dose in Spiral Breast CT With Photon-Counting Detector Technology A Phantom Study
    Shim, Sojin
    Saltybaeva, Natalia
    Berger, Nicole
    Marcon, Magda
    Alkadhi, Hatem
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2020, 55 (08) : 515 - 523