Impact of radiation dose level on CT number accuracy in photon counting CT

被引:0
|
作者
Zhang, Ran [1 ]
Cruz-Bastida, Juan P. [1 ]
Gomez-Cardona, Daniel [1 ]
Hayes, John [1 ]
Li, Ke [1 ,2 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, Madison, WI 53706 USA
关键词
TUBE CURRENT MODULATION; ITERATIVE RECONSTRUCTION; REDUCTION;
D O I
10.1117/12.2293907
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is well known that when radiation dose is reduced in x-ray computed tomography, image noise increases and noise induced streaks may appear. However, to quantify the accuracy of the image reconstruction, another source of error, known as the statistical bias, also needs to be considered. In the projection domain, signal bias originates in the quantum nature of the x-ray photon fluctuations as well as the nonlinear nature of the logarithmic transform used to generate line integral data. The bias in the projection domain is then propagated into the image domain through the image reconstruction process to generate CT number biases. The purpose of this work is to experimentally study the dependence of CT number bias on the radiation dose.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Accuracy Assessment of Photon-Counting CT for Dose Calculation in Photon Therapy
    Wu, X.
    Shah, J.
    Wohlfahrt, P.
    Wu, Q.
    Wu, Q. J.
    Sheng, Y.
    MEDICAL PHYSICS, 2024, 51 (10) : 7669 - 7669
  • [2] Radiation Dose Constraint to Maintain CT Number Accuracy
    Zhang, R.
    Cruz-Bastida, J.
    Gomez-Cardona, D.
    Hayes, J.
    Li, K.
    Chen, G.
    MEDICAL PHYSICS, 2018, 45 (06) : E135 - E135
  • [3] The Effect of the CT Number for Each CT on Photon Dose Calculation
    Cho, Kwang Hwan
    Shin, Dongho
    Cho, Sam Ju
    Jang, Jisun
    Lee, Sang Hoon
    Kim, Yong Ho
    Choi, Doo Ho
    Kim, Eun Seog
    Kwon, Soo Il
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1984 - +
  • [4] Evaluation of Varian iCBCT CT Number Accuracy For Radiation Dose Calculation
    Baillie, Devin
    Rathee, Satyapal
    MEDICAL PHYSICS, 2022, 49 (08) : 5646 - 5646
  • [5] Small animal photon counting cone-beam CT on a preclinical radiation research platform to improve radiation dose calculation accuracy
    Hu, Xiaoyu
    Zhong, Yuncheng
    Lai, Youfang
    Shen, Chenyang
    Yang, Kai
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (19):
  • [6] Photon-Counting Computed Tomography (PC-CT) of the spine: impact on diagnostic confidence and radiation dose
    Rau, Alexander
    Straehle, Jakob
    Stein, Thomas
    Diallo, Thierno
    Rau, Stephan
    Faby, Sebastian
    Nikolaou, Konstantin
    Schoenberg, Stefan O.
    Overhoff, Daniel
    Beck, Juergen
    Urbach, Horst
    Klingler, Jan-Helge
    Bamberg, Fabian
    Weiss, Jakob
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5578 - 5586
  • [7] Photon-Counting Computed Tomography (PC-CT) of the spine: impact on diagnostic confidence and radiation dose
    Alexander Rau
    Jakob Straehle
    Thomas Stein
    Thierno Diallo
    Stephan Rau
    Sebastian Faby
    Konstantin Nikolaou
    Stefan O. Schoenberg
    Daniel Overhoff
    Jürgen Beck
    Horst Urbach
    Jan-Helge Klingler
    Fabian Bamberg
    Jakob Weiss
    European Radiology, 2023, 33 : 5578 - 5586
  • [8] Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT
    Rajendran, Kishore
    Baffour, Francis
    Powell, Garret
    Glazebrook, Katrina
    Thorne, Jamison
    Larson, Nicholas
    Leng, Shuai
    McCollough, Cynthia
    Fletcher, Joel
    SKELETAL RADIOLOGY, 2023, 52 (01) : 23 - 29
  • [9] Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT
    Kishore Rajendran
    Francis Baffour
    Garret Powell
    Katrina Glazebrook
    Jamison Thorne
    Nicholas Larson
    Shuai Leng
    Cynthia McCollough
    Joel Fletcher
    Skeletal Radiology, 2023, 52 : 23 - 29
  • [10] Clinical Low Dose Photon Counting CT for the Detection of Urolithiasis: Evaluation of Image Quality and Radiation Dose
    Niehoff, Julius Henning
    Carmichael, Alexandra Fiona
    Woeltjen, Matthias Michael
    Boriesosdick, Jan
    Schmidt, Ingo Lopez
    Michael, Arwed Elias
    Hokamp, Nils Grosse
    Piechota, Hansjuergen
    Borggrefe, Jan
    Kroeger, Jan Robert
    TOMOGRAPHY, 2022, 8 (04) : 1666 - 1675