The Effect of the CT Number for Each CT on Photon Dose Calculation

被引:0
|
作者
Cho, Kwang Hwan [1 ,2 ]
Shin, Dongho [3 ]
Cho, Sam Ju [2 ]
Jang, Jisun [2 ]
Lee, Sang Hoon [2 ]
Kim, Yong Ho [1 ]
Choi, Doo Ho [1 ]
Kim, Eun Seog [1 ]
Kwon, Soo Il [2 ]
机构
[1] Soonchunhyang Univ, Coll Med, Dept Radiat Oncol, Puchon, South Korea
[2] Kyonggi Univ, Dept Med Phys, Suwon, South Korea
[3] Natl Canc Ctr, Ctr Proton Therapy, Ilsan, South Korea
关键词
Electron density; CT number; Dose calculation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The CT numbers obtained from computed tomography (CT) are potentially useful for inhomogeneity correction in CT based treatment planning. The purpose of this study is to evaluate the variation of CT number from each scanner and the effect of this variation on photon dose calculations. Five kinds of CT scanners were used to obtain images of electron density calibration phantom (Gammex RMI 467). The images were transferred to treatment planning system (Pinnacle, USA) and drawing contour of each materials for obtaining the CT number. We obtained relationship between the CT numbers and electron densities from each CT scanner. In order to investigate the influence of CT number to dose calculation, patients' thoracic CT images were used. Difference of dose was evaluated with organ (Heart, Esophagus, Tumor, Lung, Liver, Vertebra body). The differences between CT numbers for each scanner were +/-2% in homogeneous medium and 9.5% in high density medium. The maximum dose difference was 0.48% for each organ. It acquired the phantom images inserted high density material in the water phantom. Comparing the doses calculated with CT images from each CT scanner, the maximum dose difference was 2.1% in 20 cm. There was not significant difference of CT number and dose in general condition but it was different in high density medium. The exact density to CT number conversion according to CT scanner is required to minimize the uncertainty of dose depends on CT number. Especially the each hospital with various CT scanners has to discriminate CT numbers for each CT scanner. Moreover a periodic quality assurance is required for reproducibility of CT number.
引用
收藏
页码:1984 / +
页数:2
相关论文
共 50 条
  • [2] Impact of radiation dose level on CT number accuracy in photon counting CT
    Zhang, Ran
    Cruz-Bastida, Juan P.
    Gomez-Cardona, Daniel
    Hayes, John
    Li, Ke
    Chen, Guang-Hong
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [3] Accuracy Assessment of Photon-Counting CT for Dose Calculation in Photon Therapy
    Wu, X.
    Shah, J.
    Wohlfahrt, P.
    Wu, Q.
    Wu, Q. J.
    Sheng, Y.
    MEDICAL PHYSICS, 2024, 51 (10) : 7669 - 7669
  • [4] Dose Calculation Using Dual Energy CT in Photon Radiation Therapy
    Qin, Y.
    Bunker, A.
    Foster, R.
    Xu, M.
    Soen, J.
    Pankuch, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E722 - E722
  • [5] Evaluation of Varian iCBCT CT Number Accuracy For Radiation Dose Calculation
    Baillie, Devin
    Rathee, Satyapal
    MEDICAL PHYSICS, 2022, 49 (08) : 5646 - 5646
  • [6] A review of dose calculation approaches with cone beam CT in photon and proton therapy
    Giacometti, Valentina
    Hounsell, Alan R.
    McGarry, Conor K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 243 - 276
  • [7] Comparison of CT number calibration techniques for CBCT-based dose calculation
    Dunlop, Alex
    McQuaid, Dualta
    Nill, Simeon
    Murray, Julia
    Poludniowski, Gavin
    Hansen, Vibeke N.
    Bhide, Shreerang
    Nutting, Christopher
    Harrington, Kevin
    Newbold, Kate
    Oelfke, Uwe
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (12) : 970 - 978
  • [8] The Effect of Reducing CT Dose on Proton Therapy Dose Calculation - Phantom Study
    Elhamiasl, M.
    Salvo, K.
    Sterpin, E.
    Nuyts, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1512 - S1513
  • [9] A Quantitative Evaluation of the Effect of CT Scanning Parameters On CT Number to Density Calibration and Dose Calculations
    Refaei, S.
    Lamba, M.
    Elson, H.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [10] Dose calculation on cone beam CT (CBCT)
    Chi, Y.
    Wu, Q.
    Yan, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2438 - 2438