Wear estimation of hip implants with varying chamfer geometry at the trunnion junction: a finite element analysis

被引:24
|
作者
Gutmann, Celine [1 ]
Shaikh, Numa [2 ]
Shenoy, B. Satish [3 ]
Bhat, N. Shaymasunder [4 ]
Keni, Laxmikant G. [3 ]
Chethan, K. N. [3 ]
机构
[1] Univ Appl Sci Northwestern Switzerland, Inst Med Engn & Med Informat, Sch Life Sci HLS, FHNW, Windisch, Switzerland
[2] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Mech & Ind Engn, Manipal, Karnataka, India
[3] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Aeronaut & Automobile Engn, Manipal, Karnataka, India
[4] Manipal Acad Higher Educ, Kasturba Med Coll, Dept Orthopaed, Manipal, Karnataka, India
关键词
hip implant; finite element analysis; ansys; linear wear; pressure; TAPER JUNCTION; FRETTING WEAR; ARTHROPLASTY; STEM; REPLACEMENTS; FAILURE; RATES;
D O I
10.1088/2057-1976/acb710
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The hip joint helps the upper body to transfer its weight to lower body. Along with age, there are various reasons for the degeneration of the hip joint. The artificial hip implant replaces the degenerated hip. Wear between the joints is the primary cause of the hip implant becoming loose. The wear can occur due to various reasons. Due to this revision surgery are most common in young and active patients. In the design phase of the implant if this is taken care then life expectancy of the implant can be improved. Small design changes can significantly enhance the implant's life. In this work, elliptical-shaped hip implant stem is designed, and linear wear is estimated at trunnion junction. In this work, a 28 mm diameter femoral head with a 4 mm thick acetabular cup and a 2 mm thick backing cup is used. The top surface taper radiuses are changed. Solid works was used to create the models. Ansys was used to perform the analysis. It was found that as the radius of the TTR decreased, the wear rate decreased. The least wear rate was found in 12/14 mm taper with a value of 1.15E(-02) mm year(-1) for the first material combination and with a value of 1.23E (-02) mm year(-1) for the second material combination. In the comparison between the models with 1 mm chamfer and no chamfer, it was found that the wear rate was lower for the models with 1 mm chamfer. When the chamfer was increased (more than 1 mm), the linear wear increased. Wear is the main reason for the loosening of hip implants, which leads to a revision of an implant. It was found that with a decrease in TTR, there was a small increase in the linear wear rate. Overall, the implant with TTR 6 mm and a chamfer of 1 mm was found to have the least wear rate. To validate these results, the implant can be 3D printed and tested on a hip simulator.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Finite element contact analysis of the hip joint
    Bachtar, Fuziansyah
    Chen, Xian
    Hisada, Toshiaki
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (08) : 643 - 651
  • [42] Finite element analysis of hip stem designs
    Bennett, David
    Goswami, Tarun
    MATERIALS & DESIGN, 2008, 29 (01) : 45 - 60
  • [43] FINITE ELEMENT ANALYSIS OF MODIFIED HIP PROSTHESIS
    Shinge, Abhijit. R.
    Anasane, Sandip S.
    Aitavade, Eknath N.
    Mahadik, Sachinkumar S.
    Mulik, Pramod V.
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2011, 2 (02): : 278 - 285
  • [44] Finite element contact analysis of the hip joint
    Fuziansyah Bachtar
    Xian Chen
    Toshiaki Hisada
    Medical and Biological Engineering and Computing, 2006, 44 : 643 - 651
  • [45] Finite element-based preclinical testing of cemented total hip implants
    Stolk, Jan
    Janssen, Dennis
    Huiskes, Rik
    Verdonschot, Nico
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (456) : 138 - 147
  • [46] Can finite element models detect clinically inferior cemented hip implants?
    Stolk, J
    Maher, SA
    Verdonschot, N
    Prendergast, PJ
    Huiskes, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (409) : 138 - 150
  • [47] Evolution of different designs and wear studies in total hip prosthesis using finite element analysis: A review
    Chethan, K. N.
    Bhat, Shyamasunder N.
    Zuber, Mohammad
    Shenoy, Satish B.
    COGENT ENGINEERING, 2022, 9 (01):
  • [48] Experimental and Finite Element Wear Study of Silicon Nitride Against Alumina for Hip Implants with Bio-Lubricant for Various Gait Activities
    Shankar, S.
    Nithyaprakash, R.
    Sugunesh, A. P.
    Selvamani, A.
    Uddin, M. S.
    SILICON, 2021, 13 (03) : 633 - 644
  • [49] Experimental and Finite Element Wear Study of Silicon Nitride Against Alumina for Hip Implants with Bio-Lubricant for Various Gait Activities
    S. Shankar
    R. Nithyaprakash
    A. P. Sugunesh
    K. A. Selvamani
    M. S. Uddin
    Silicon, 2021, 13 : 633 - 644
  • [50] Finite element analysis of hip implant with varying in taper neck lengths under static loading conditions
    Chethan, K. N.
    Bhat, N. Shyamasunder
    Zuber, Mohammad
    Shenoy, B. Satish
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 208