Wear estimation of hip implants with varying chamfer geometry at the trunnion junction: a finite element analysis

被引:24
|
作者
Gutmann, Celine [1 ]
Shaikh, Numa [2 ]
Shenoy, B. Satish [3 ]
Bhat, N. Shaymasunder [4 ]
Keni, Laxmikant G. [3 ]
Chethan, K. N. [3 ]
机构
[1] Univ Appl Sci Northwestern Switzerland, Inst Med Engn & Med Informat, Sch Life Sci HLS, FHNW, Windisch, Switzerland
[2] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Mech & Ind Engn, Manipal, Karnataka, India
[3] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Aeronaut & Automobile Engn, Manipal, Karnataka, India
[4] Manipal Acad Higher Educ, Kasturba Med Coll, Dept Orthopaed, Manipal, Karnataka, India
关键词
hip implant; finite element analysis; ansys; linear wear; pressure; TAPER JUNCTION; FRETTING WEAR; ARTHROPLASTY; STEM; REPLACEMENTS; FAILURE; RATES;
D O I
10.1088/2057-1976/acb710
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The hip joint helps the upper body to transfer its weight to lower body. Along with age, there are various reasons for the degeneration of the hip joint. The artificial hip implant replaces the degenerated hip. Wear between the joints is the primary cause of the hip implant becoming loose. The wear can occur due to various reasons. Due to this revision surgery are most common in young and active patients. In the design phase of the implant if this is taken care then life expectancy of the implant can be improved. Small design changes can significantly enhance the implant's life. In this work, elliptical-shaped hip implant stem is designed, and linear wear is estimated at trunnion junction. In this work, a 28 mm diameter femoral head with a 4 mm thick acetabular cup and a 2 mm thick backing cup is used. The top surface taper radiuses are changed. Solid works was used to create the models. Ansys was used to perform the analysis. It was found that as the radius of the TTR decreased, the wear rate decreased. The least wear rate was found in 12/14 mm taper with a value of 1.15E(-02) mm year(-1) for the first material combination and with a value of 1.23E (-02) mm year(-1) for the second material combination. In the comparison between the models with 1 mm chamfer and no chamfer, it was found that the wear rate was lower for the models with 1 mm chamfer. When the chamfer was increased (more than 1 mm), the linear wear increased. Wear is the main reason for the loosening of hip implants, which leads to a revision of an implant. It was found that with a decrease in TTR, there was a small increase in the linear wear rate. Overall, the implant with TTR 6 mm and a chamfer of 1 mm was found to have the least wear rate. To validate these results, the implant can be 3D printed and tested on a hip simulator.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] FINITE-ELEMENT ANALYSIS OF DENTAL IMPLANTS
    COOK, SD
    KLAWITTER, J
    JOURNAL OF DENTAL RESEARCH, 1978, 57 : 259 - 259
  • [32] How does bicycling affect the longevity of Total Hip Arthroplasty? A finite element wear analysis
    Toh, Shawn Ming Song
    Ashkanfar, Ariyan
    English, Russell
    Rothwell, Glynn
    Langton, David J.
    Joyce, Thomas J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 139
  • [33] Finite element analysis of narrow dental implants
    Valera-Jimenez, J. F.
    Burgueno-Barris, G.
    Gomez-Gonzalez, S.
    Lopez-Lopez, J.
    Valmaseda-Castellon, E.
    Fernandez-Aguado, E.
    DENTAL MATERIALS, 2020, 36 (07) : 927 - 935
  • [34] Local head roughening as a factor contributing to variability of total hip wear: A finite element analysis
    Brown, TD
    Stewart, KJ
    Nieman, JC
    Pedersen, DR
    Callaghan, JJ
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (06): : 691 - 698
  • [35] Finite element modeling of a generic stemless hip implant design in comparison with conventional hip implants
    Asgari, SA
    Hamouda, AMS
    Mansor, SB
    Singh, H
    Mahdi, E
    Wirza, R
    Prakash, B
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2004, 40 (15) : 2027 - 2047
  • [36] Finite element simulation of early creep and wear in total hip arthroplasty
    Bevill, SL
    Bevill, GR
    Penmetsa, JR
    Petrella, AJ
    Rullkoetter, PJ
    JOURNAL OF BIOMECHANICS, 2005, 38 (12) : 2365 - 2374
  • [37] FINITE ELEMENT ANALYSIS OF CUSTOMIZED KNEE IMPLANTS BY VARYING LOADS DURING FLEXION-EXTENSION MOVEMENT
    Alshewaier, Shady A. A.
    Alshehri, Majed Ali Ghurmallah
    Begum, S. Sabarunisha
    Sikkandar, Mohamed Yacin
    Almukil, Ali Abdullah A.
    Alhazmi, Aishah Mohammad
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (06)
  • [38] Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
    Darwich, Ayham
    Nazha, Hasan
    Daoud, Monzer
    JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS, 2020, 6 (02): : 284 - 295
  • [39] Finite element analysis of torsional fretting wear
    Zhang, Yu-Mei
    Deng, Sha-Sha
    Tan, Tian-Cai
    Liu, Juan
    Shen, Huo-Ming
    Sichuan Daxue Xuebao (Gongcheng Kexue Ban)/Journal of Sichuan University (Engineering Science Edition), 2010, 42 (SUPPL. 2): : 110 - 112
  • [40] Analysis of modified surface topographies of titanium-based hip implants using finite element method
    Vulovic, Aleksandra
    Warchomicka, Fernando Gustavo
    Pixner, Florian
    Filipovic, Nenad
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (02) : 1123 - 1133