Calibration of patient-specific boundary conditions for coupled CFD models of the aorta derived from 4D Flow-MRI

被引:13
|
作者
Black, Scott MacDonald [1 ]
Maclean, Craig [2 ]
Hall Barrientos, Pauline [3 ]
Ritos, Konstantinos [4 ,5 ]
McQueen, Alistair [6 ]
Kazakidi, Asimina [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, Glasgow, Scotland
[2] Terumo Aortic, Res & Dev, Glasgow, Scotland
[3] NHS Greater Glasgow & Clyde, Queen Elizabeth Univ Hosp, Clin Phys, Glasgow, Scotland
[4] Univ Strathclyde, Dept Mech & Aerosp Engn, Glasgow, Scotland
[5] Univ Thessaly, Dept Mech Engn, Volos, Greece
[6] Univ Glasgow, Dept Biomed Engn, Glasgow, Scotland
基金
英国工程与自然科学研究理事会; 英国科研创新办公室;
关键词
CFD; 4D Flow-MRI; boundary conditions; calibration; Windkessel; aortic dissection; patient-specific; WALL SHEAR-STRESS; PULSE-WAVE VELOCITY; BLOOD-FLOW; TEAR SIZE; ARCH; HEMODYNAMICS; PRESSURE; SIMULATION; ATHEROSCLEROSIS; BIFURCATION;
D O I
10.3389/fbioe.2023.1178483
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: Patient-specific computational fluid dynamics (CFD) models permit analysis of complex intra-aortic hemodynamics in patients with aortic dissection (AD), where vessel morphology and disease severity are highly individualized. The simulated blood flow regime within these models is sensitive to the prescribed boundary conditions (BCs), so accurate BC selection is fundamental to achieve clinically relevant results. Methods: This study presents a novel reduced-order computational framework for the iterative flow-based calibration of 3-Element Windkessel Model (3EWM) parameters to generate patient-specific BCs. These parameters were calibrated using time-resolved flow information derived from retrospective four-dimensional flow magnetic resonance imaging (4D Flow-MRI). For a healthy and dissected case, blood flow was then investigated numerically in a fully coupled zero dimensional-three dimensional (0D-3D) numerical framework, where the vessel geometries were reconstructed from medical images. Calibration of the 3EWM parameters was automated and required similar to 3.5 min per branch. Results: With prescription of the calibrated BCs, the computed near-wall hemodynamics (time-averaged wall shear stress, oscillatory shear index) and perfusion distribution were consistent with clinical measurements and previous literature, yielding physiologically relevant results. BC calibration was particularly important in the AD case, where the complex flow regime was captured only after BC calibration. Discussion: This calibration methodology can therefore be applied in clinical cases where branch flow rates are known, for example, via 4D Flow-MRI or ultrasound, to generate patient-specific BCs for CFD models. It is then possible to elucidate, on a case-by-case basis, the highly individualized hemodynamics which occur due to geometric variations in aortic pathology high spatiotemporal resolution through CFD.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] PATIENT-SPECIFIC MODELING OF LEFT HEART ANATOMY, DYNAMICS AND HEMODYNAMICS FROM HIGH RESOLUTION 4D CT
    Mihalef, Viorel
    Ionasec, Razvan
    Wang, Yang
    Zheng, Yefeng
    Georgescu, Bogdan
    Comaniciu, Dorin
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 504 - 507
  • [42] 4D Flow MRI in 3D Printed Models of Aorta Grafted With a Ventricular Assist Device Allows Detailed Embolic Trajectory Analysis
    Amili, O.
    Coletti, F.
    MacIver, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S59 - S59
  • [43] Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation: comparison with young healthy volunteers
    Rengier, Fabian
    Delles, Michael
    Eichhorn, Joachim
    Azad, Yoo-Jin
    von Tengg-Kobligk, Hendrik
    Ley-Zaporozhan, Julia
    Dillmann, Ruediger
    Kauczor, Hans-Ulrich
    Unterhinninghofen, Roland
    Ley, Sebastian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (04): : 823 - 830
  • [44] Patient-Specific Model of Left Heart Anatomy, Dynamics and Hemodynamics from 4D TEE: A First Validation Study
    Voigt, Ingmar
    Mansi, Tommaso
    Mihalef, Viorel
    Ionasec, Razvan Ioan
    Calleja, Anna
    Mengue, Etienne Assoumou
    Sharma, Puneet
    Houle, Helene
    Georgescu, Bogdan
    Hornegger, Joachim
    Comaniciu, Dorin
    FUNCTIONAL IMAGING AND MODELING OF THE HEART, 2011, 6666 : 341 - 349
  • [45] Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation: comparison with young healthy volunteers
    Fabian Rengier
    Michael Delles
    Joachim Eichhorn
    Yoo-Jin Azad
    Hendrik von Tengg-Kobligk
    Julia Ley-Zaporozhan
    Rüdiger Dillmann
    Hans-Ulrich Kauczor
    Roland Unterhinninghofen
    Sebastian Ley
    The International Journal of Cardiovascular Imaging, 2015, 31 : 823 - 830
  • [46] Application of anatomically accurate, patient-specific 3D printed models from MRI data in urological oncology
    Wake, N.
    Chandarana, H.
    Huang, W. C.
    Taneja, S. S.
    Rosenkrantz, A. B.
    CLINICAL RADIOLOGY, 2016, 71 (06) : 610 - 614
  • [47] Circulation derived from 4D flow MRI correlates with right ventricular dysfunction in patients with tetralogy of Fallot
    Tsuchiya, Nanae
    Nagao, Michinobu
    Shiina, Yumi
    Miyazaki, Shohei
    Inai, Kei
    Murayama, Sadayuki
    Sakai, Shuji
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [48] Circulation derived from 4D flow MRI correlates with right ventricular dysfunction in patients with tetralogy of Fallot
    Nanae Tsuchiya
    Michinobu Nagao
    Yumi Shiina
    Shohei Miyazaki
    Kei Inai
    Sadayuki Murayama
    Shuji Sakai
    Scientific Reports, 11
  • [49] Non-invasive pulmonary blood flow analysis and blood pressure mapping derived from 4D flow MRI
    Delles, Michael
    Rengier, Fabian
    Azad, Yoo-Jin
    Bodenstedt, Sebastian
    von Tengg-Kobligk, Hendrik
    Ley, Sebastian
    Unterhinninghofen, Roland
    Kauczor, Hans-Ulrich
    Dillmann, Ruediger
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [50] Aortic hemodynamics assessment prior and after valve sparing reconstruction: A patient-specific 4D flow-based FSI model
    Nannini, Guido
    Caimi, Alessandro
    Palumbo, Maria Chiara
    Saitta, Simone
    Girardi, Leonard N.
    Gaudino, Mario
    Roman, Mary J.
    Weinsaft, Jonathan W.
    Redaelli, Alberto
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 135