Calibration of patient-specific boundary conditions for coupled CFD models of the aorta derived from 4D Flow-MRI

被引:13
|
作者
Black, Scott MacDonald [1 ]
Maclean, Craig [2 ]
Hall Barrientos, Pauline [3 ]
Ritos, Konstantinos [4 ,5 ]
McQueen, Alistair [6 ]
Kazakidi, Asimina [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, Glasgow, Scotland
[2] Terumo Aortic, Res & Dev, Glasgow, Scotland
[3] NHS Greater Glasgow & Clyde, Queen Elizabeth Univ Hosp, Clin Phys, Glasgow, Scotland
[4] Univ Strathclyde, Dept Mech & Aerosp Engn, Glasgow, Scotland
[5] Univ Thessaly, Dept Mech Engn, Volos, Greece
[6] Univ Glasgow, Dept Biomed Engn, Glasgow, Scotland
基金
英国工程与自然科学研究理事会; 英国科研创新办公室;
关键词
CFD; 4D Flow-MRI; boundary conditions; calibration; Windkessel; aortic dissection; patient-specific; WALL SHEAR-STRESS; PULSE-WAVE VELOCITY; BLOOD-FLOW; TEAR SIZE; ARCH; HEMODYNAMICS; PRESSURE; SIMULATION; ATHEROSCLEROSIS; BIFURCATION;
D O I
10.3389/fbioe.2023.1178483
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: Patient-specific computational fluid dynamics (CFD) models permit analysis of complex intra-aortic hemodynamics in patients with aortic dissection (AD), where vessel morphology and disease severity are highly individualized. The simulated blood flow regime within these models is sensitive to the prescribed boundary conditions (BCs), so accurate BC selection is fundamental to achieve clinically relevant results. Methods: This study presents a novel reduced-order computational framework for the iterative flow-based calibration of 3-Element Windkessel Model (3EWM) parameters to generate patient-specific BCs. These parameters were calibrated using time-resolved flow information derived from retrospective four-dimensional flow magnetic resonance imaging (4D Flow-MRI). For a healthy and dissected case, blood flow was then investigated numerically in a fully coupled zero dimensional-three dimensional (0D-3D) numerical framework, where the vessel geometries were reconstructed from medical images. Calibration of the 3EWM parameters was automated and required similar to 3.5 min per branch. Results: With prescription of the calibrated BCs, the computed near-wall hemodynamics (time-averaged wall shear stress, oscillatory shear index) and perfusion distribution were consistent with clinical measurements and previous literature, yielding physiologically relevant results. BC calibration was particularly important in the AD case, where the complex flow regime was captured only after BC calibration. Discussion: This calibration methodology can therefore be applied in clinical cases where branch flow rates are known, for example, via 4D Flow-MRI or ultrasound, to generate patient-specific BCs for CFD models. It is then possible to elucidate, on a case-by-case basis, the highly individualized hemodynamics which occur due to geometric variations in aortic pathology high spatiotemporal resolution through CFD.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Patient-specific flow simulation of the left ventricle from 4D echocardiography - feasibility and robustness evaluation
    Larsson, David
    Spuhler, Jeannette H.
    Nordenfur, Tim
    Hoffman, Johan
    Colarieti-Tosti, Massimiliano
    Gao, Hang
    Larsson, Matilda
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [22] Methodology of generation of CFD meshes and 4D shape reconstruction of coronary arteries from patient-specific dynamic CT
    Krzysztof Psiuk-Maksymowicz
    Damian Borys
    Bartlomiej Melka
    Maria Gracka
    Wojciech P. Adamczyk
    Marek Rojczyk
    Jaroslaw Wasilewski
    Jan Głowacki
    Mariusz Kruk
    Marcin Nowak
    Ziemowit Ostrowski
    Ryszard A. Bialecki
    Scientific Reports, 14
  • [23] Methodology of generation of CFD meshes and 4D shape reconstruction of coronary arteries from patient-specific dynamic CT
    Psiuk-Maksymowicz, Krzysztof
    Borys, Damian
    Melka, Bartlomiej
    Gracka, Maria
    Adamczyk, Wojciech P.
    Rojczyk, Marek
    Wasilewski, Jaroslaw
    Glowacki, Jan
    Kruk, Mariusz
    Nowak, Marcin
    Ostrowski, Ziemowit
    Bialecki, Ryszard A.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [24] Patient-specific CFD modelling in the thoracic aorta with PC-MRI-based boundary conditions: A least-square three-element Windkessel approach
    Romarowski, Rodrigo M.
    Lefieux, Adrien
    Morganti, Simone
    Veneziani, Alessandro
    Auricchio, Ferdinando
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2018, 34 (11)
  • [25] Enhanced 4D Flow MRI-Based CFD with Adaptive Mesh Refinement for Flow Dynamics Assessment in Coarctation of the Aorta
    Shahid, Labib
    Rice, James
    Berhane, Haben
    Rigsby, Cynthia
    Robinson, Joshua
    Griffin, Lindsay
    Markl, Michael
    Roldan-Alzate, Alejandro
    ANNALS OF BIOMEDICAL ENGINEERING, 2022, 50 (08) : 1001 - 1016
  • [26] Enhanced 4D Flow MRI-Based CFD with Adaptive Mesh Refinement for Flow Dynamics Assessment in Coarctation of the Aorta
    Labib Shahid
    James Rice
    Haben Berhane
    Cynthia Rigsby
    Joshua Robinson
    Lindsay Griffin
    Michael Markl
    Alejandro Roldán-Alzate
    Annals of Biomedical Engineering, 2022, 50 : 1001 - 1016
  • [27] 4D phase contrast MRI in intracranial aneurysms: a comparison with patient-specific computational fluid dynamics with temporal and spatial velocity boundary conditions as measured with 3D phase contrast MRI
    Pim van Ooij
    Joppe Schneiders
    Henk Marquering
    Charles B Majoie
    Ed vanBavel
    Aart Nederveen
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [28] PHASE CONTRAST MRI DERIVED BOUNDARY CONDITIONS FOR PATIENT SPECIFIC AAA FLUID FLOW MODELING
    Chandra, Santanu
    Raut, Samarth S.
    Malve, Mauro
    Scotti, Christine M.
    Finol, Ender A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 235 - 236
  • [29] On the relevance of boundary conditions and viscosity models in blood flow simulations in patient-specific aorto-coronary bypass models
    Jonasova, Alena
    Vimmr, Jan
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (04)
  • [30] COMBINING 4D MRI WITH CFD FOR INVESTIGATING PATIENT-SPECIFIC CARDIOVASCULAR FLOWS: A COMPREHENSIVE COMPARISON OF ANSYS, COMSOL, AND SIMVASCULAR ILLUSTRATED WITH THE PREDICTION OF THORACIC AORTIC HEMODYNAMICS
    Tajeddini, Farshad
    Romero, David A.
    McClarty, Davis
    Chung, Jennifer
    Amon, Cristina H.
    PROCEEDINGS OF ASME 2022 FLUIDS ENGINEERING DIVISION SUMMER MEETING, FEDSM2022, VOL 2, 2022,