Calibration of patient-specific boundary conditions for coupled CFD models of the aorta derived from 4D Flow-MRI

被引:13
|
作者
Black, Scott MacDonald [1 ]
Maclean, Craig [2 ]
Hall Barrientos, Pauline [3 ]
Ritos, Konstantinos [4 ,5 ]
McQueen, Alistair [6 ]
Kazakidi, Asimina [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, Glasgow, Scotland
[2] Terumo Aortic, Res & Dev, Glasgow, Scotland
[3] NHS Greater Glasgow & Clyde, Queen Elizabeth Univ Hosp, Clin Phys, Glasgow, Scotland
[4] Univ Strathclyde, Dept Mech & Aerosp Engn, Glasgow, Scotland
[5] Univ Thessaly, Dept Mech Engn, Volos, Greece
[6] Univ Glasgow, Dept Biomed Engn, Glasgow, Scotland
基金
英国工程与自然科学研究理事会; 英国科研创新办公室;
关键词
CFD; 4D Flow-MRI; boundary conditions; calibration; Windkessel; aortic dissection; patient-specific; WALL SHEAR-STRESS; PULSE-WAVE VELOCITY; BLOOD-FLOW; TEAR SIZE; ARCH; HEMODYNAMICS; PRESSURE; SIMULATION; ATHEROSCLEROSIS; BIFURCATION;
D O I
10.3389/fbioe.2023.1178483
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: Patient-specific computational fluid dynamics (CFD) models permit analysis of complex intra-aortic hemodynamics in patients with aortic dissection (AD), where vessel morphology and disease severity are highly individualized. The simulated blood flow regime within these models is sensitive to the prescribed boundary conditions (BCs), so accurate BC selection is fundamental to achieve clinically relevant results. Methods: This study presents a novel reduced-order computational framework for the iterative flow-based calibration of 3-Element Windkessel Model (3EWM) parameters to generate patient-specific BCs. These parameters were calibrated using time-resolved flow information derived from retrospective four-dimensional flow magnetic resonance imaging (4D Flow-MRI). For a healthy and dissected case, blood flow was then investigated numerically in a fully coupled zero dimensional-three dimensional (0D-3D) numerical framework, where the vessel geometries were reconstructed from medical images. Calibration of the 3EWM parameters was automated and required similar to 3.5 min per branch. Results: With prescription of the calibrated BCs, the computed near-wall hemodynamics (time-averaged wall shear stress, oscillatory shear index) and perfusion distribution were consistent with clinical measurements and previous literature, yielding physiologically relevant results. BC calibration was particularly important in the AD case, where the complex flow regime was captured only after BC calibration. Discussion: This calibration methodology can therefore be applied in clinical cases where branch flow rates are known, for example, via 4D Flow-MRI or ultrasound, to generate patient-specific BCs for CFD models. It is then possible to elucidate, on a case-by-case basis, the highly individualized hemodynamics which occur due to geometric variations in aortic pathology high spatiotemporal resolution through CFD.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Patient-specific CFD models for intraventricular flow analysis from 3D ultrasound imaging: Comparison of three clinical cases
    Bavo, A. M.
    Pouch, A. M.
    Degroote, J.
    Vierendeels, J.
    Gorman, J. H.
    Gorman, R. C.
    Segers, P.
    JOURNAL OF BIOMECHANICS, 2017, 50 : 144 - 150
  • [32] Dynamic 4D Blood Flow Representation in the Aorta and Analysis from Cine-MRI in Patients
    Xavier, M.
    Lalande, A.
    Walker, P. M.
    Boichot, C.
    Cochet, A.
    Bouchot, O.
    Steinmetz, E.
    Legrand, L.
    Brunotte, F.
    COMPUTERS IN CARDIOLOGY 2007, VOL 34, 2007, 34 : 375 - +
  • [33] Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta
    van Ooij, Pim
    Powell, Alexander L.
    Potters, Wouter V.
    Carr, James C.
    Markl, Michael
    Barker, Alex J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 236 - 248
  • [34] Quantification and comparison of 4D Flow MRI derived wall shear stress and MRE derived wall shear stiffness of abdominal aorta
    Venkata Sita Priyanka Illapani
    Julio Garcia
    Ria Mazumder
    Richard D White
    Michael Markl
    Arunark Kolipaka
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [35] 4-D Flow MRI-Based Computational Analysis of Blood Flow in Patient-Specific Aortic Dissection
    Pirola, Selene
    Guo, Baolei
    Menichini, Claudia
    Saitta, Simone
    Fu, Weiguo
    Dong, Zhihui
    Xu, Xiao Yun
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (12) : 3411 - 3419
  • [36] Reproducibility and inter-observer variability of velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta
    Pim van Ooij
    Alexander L Powell
    Wouter V Potters
    Alex J Barker
    Michael Markl
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [37] Fluid mechanics of blood flow in human fetal left ventricles based on patient-specific 4D ultrasound scans
    Chang Quan Lai
    Guat Ling Lim
    Muhammad Jamil
    Citra Nurfarah Zaini Mattar
    Arijit Biswas
    Choon Hwai Yap
    Biomechanics and Modeling in Mechanobiology, 2016, 15 : 1159 - 1172
  • [38] Fluid mechanics of blood flow in human fetal left ventricles based on patient-specific 4D ultrasound scans
    Lai, Chang Quan
    Lim, Guat Ling
    Jamil, Muhammad
    Mattar, Citra Nurfarah Zaini
    Biswas, Arijit
    Yap, Choon Hwai
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2016, 15 (05) : 1159 - 1172
  • [39] Fluoroscopic 3D Image Generation from Patient-Specific PCA Motion Models Derived from 4D-CBCT Patient Datasets: A Feasibility Study
    Dhou, Salam
    Alkhodari, Mohanad
    Ionascu, Dan
    Williams, Christopher
    Lewis, John H.
    JOURNAL OF IMAGING, 2022, 8 (02)
  • [40] 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images
    Dhou, S.
    Ionascu, D.
    Cai, W.
    Hurwitz, M.
    Williams, C.
    Lewis, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3328 - 3328