The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis

被引:17
|
作者
Fan, Shengchi [1 ,2 ]
Saenz-Ravello, Gustavo [3 ]
Diaz, Leonardo [4 ]
Wu, Yiqun [2 ]
Davo, Ruben [5 ]
Wang, Feng [2 ]
Magic, Marko [6 ]
Al-Nawas, Bilal [1 ]
Kaemmerer, Peer W. [1 ]
机构
[1] Univ Med Ctr Mainz, Dept Oral & Maxillofacial Surg, Plast Operat, D-55131 Mainz, Germany
[2] Shanghai Jiao Tong Univ, Peoples Hosp 9, Shanghai Res Inst Stomatol, Coll Stomatol,Dent Clin 2,Sch Med,Shanghai Key Lab, Shanghai 200011, Peoples R China
[3] Univ Chile, Fac Dent, Ctr Epidemiol & Surveillance Oral Dis CESOD, Santiago 8380420, Chile
[4] Univ Chile, Fac Dent, Postgrad Sch, Santiago 8380420, Chile
[5] Vithas Davo Inst Dent, Dept Implantol & Maxillofacial Surg, Alicante 03016, Spain
[6] Univ Belgrade, Sch Dent Med, Belgrade 11000, Serbia
关键词
zygomatic implant; edentulous; computer-aided surgery; navigation; guided surgery; SURGICAL NAVIGATION; GUIDED SURGERY; REHABILITATION; MANAGEMENT; MAXILLA; ERROR;
D O I
10.3390/jcm12165418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla. Methods: Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS. Results: A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34-2.29) at the entry point and 2.95 mm (95% CI: 1.66-4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04-4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83-1.54) at the entry point and 1.80 mm (95% CI: 1.10-2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43-2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69-2.39) at the entry point and 3.23 mm (95% CI: 2.34-4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86-5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups (p < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements. Conclusion: Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] The Accuracy of Dental Implant Placement With Different Methods of Computer-Assisted Implant Surgery: A Network Meta-Analysis of Clinical Studies
    Mahardawi, Basel
    Jiaranuchart, Sirimanas
    Arunjaroensuk, Sirida
    Dhanesuan, Kanit
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (01) : 1 - 16
  • [32] Three-Dimensional Accuracy of Surgical Guides for Static Computer-Aided Implant Surgery: A Systematic Review
    Lo Russo, Lucio
    Pierluigi, Mariani
    Zhurakivska, Khrystyna
    Digregorio, Chiara
    Lo Muzio, Eleonora
    Laino, Luigi
    PROSTHESIS, 2023, 5 (03): : 809 - 825
  • [33] The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis
    Putra, Ramadhan Hardani
    Yoda, Nobuhiro
    Astuti, Eha Renwi
    Sasaki, Keiichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) : 29 - 39
  • [34] Accuracy of freehand versus dynamic computer-assisted zygomatic implant placement: An in-vitro study
    Traboulsi-Garet, Bassel
    Jorba-Garcia, Adria
    Bara-Casaus, Javier
    Camps-Font, Octavi
    Valmaseda-Castellon, Eduard
    Figueiredo, Rui
    Sanchez-Garces, M. Angeles
    JOURNAL OF DENTISTRY, 2025, 155
  • [35] Computer-Aided Polyp Detection During Colonoscopy: A Systematic Review and Meta-Analysis
    Moosvi, Zain
    Shah, Sagar
    Ortizo, Ronald
    Samarasena, Jason
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2020, 115 : S148 - S148
  • [36] Efficacy of Computer-Aided Static Navigation Technique on the Accuracy of Endodontic Microsurgery. A Systematic Review and Meta-Analysis
    Zubizarreta-Macho, Alvaro
    Castillo-Amature, Cesar
    Maria Montiel-Company, Jose
    Mena-Alvarez, Jesus
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (02) : 1 - 10
  • [37] Computer-aided screening of aspiration risks in dysphagia with wearable technology: a Systematic Review and meta-analysis on test accuracy
    Lai, Derek Ka-Hei
    Cheng, Ethan Shiu-Wang
    Lim, Hyo-Jung
    So, Bryan Pak-Hei
    Lam, Wing-Kai
    Cheung, Daphne Sze Ki
    Wong, Duo Wai-Chi
    Cheung, James Chung-Wai
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [38] Technique-Related Survival Rate and Complications of Zygomatic Implant Placement: A Systematic Review and Meta-Analysis
    Gabriele, Guido
    Chisci, Glauco
    Cascino, Flavia
    Ricci, Nicolo Maria
    Marruganti, Crystal
    Ferrari, Marco
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (05) : 855 - +
  • [39] Accuracy of Augmented Reality-Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis
    Mai, Hang-Nga
    Dam, Van Viet
    Lee, Du-Hyeong
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2023, 25 (01)
  • [40] Immediate implant placement with flap or flapless surgery: A systematic review and meta-analysis
    Pitman, Jeremy
    Christiaens, Veronique
    Callens, Jeroen
    Glibert, Maarten
    Seyssens, Lorenz
    Blanco, Juan
    Cosyn, Jan
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2023, : 755 - 764