The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis

被引:17
|
作者
Fan, Shengchi [1 ,2 ]
Saenz-Ravello, Gustavo [3 ]
Diaz, Leonardo [4 ]
Wu, Yiqun [2 ]
Davo, Ruben [5 ]
Wang, Feng [2 ]
Magic, Marko [6 ]
Al-Nawas, Bilal [1 ]
Kaemmerer, Peer W. [1 ]
机构
[1] Univ Med Ctr Mainz, Dept Oral & Maxillofacial Surg, Plast Operat, D-55131 Mainz, Germany
[2] Shanghai Jiao Tong Univ, Peoples Hosp 9, Shanghai Res Inst Stomatol, Coll Stomatol,Dent Clin 2,Sch Med,Shanghai Key Lab, Shanghai 200011, Peoples R China
[3] Univ Chile, Fac Dent, Ctr Epidemiol & Surveillance Oral Dis CESOD, Santiago 8380420, Chile
[4] Univ Chile, Fac Dent, Postgrad Sch, Santiago 8380420, Chile
[5] Vithas Davo Inst Dent, Dept Implantol & Maxillofacial Surg, Alicante 03016, Spain
[6] Univ Belgrade, Sch Dent Med, Belgrade 11000, Serbia
关键词
zygomatic implant; edentulous; computer-aided surgery; navigation; guided surgery; SURGICAL NAVIGATION; GUIDED SURGERY; REHABILITATION; MANAGEMENT; MAXILLA; ERROR;
D O I
10.3390/jcm12165418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla. Methods: Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS. Results: A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34-2.29) at the entry point and 2.95 mm (95% CI: 1.66-4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04-4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83-1.54) at the entry point and 1.80 mm (95% CI: 1.10-2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43-2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69-2.39) at the entry point and 3.23 mm (95% CI: 2.34-4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86-5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups (p < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements. Conclusion: Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Static computer-aided, partially guided, and free-handed implant placement: A systematic review and meta-analysis of randomized controlled trials
    Tattan, Mustafa
    Chambrone, Leandro
    Gonzalez-Martin, Oscar
    Avila-Ortiz, Gustavo
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (10) : 889 - 916
  • [22] Accuracy of Computer-Aided Diagnosis of Melanoma A Meta-analysis
    Dick, Vincent
    Sinz, Christoph
    Mittlboeck, Martina
    Kittler, Harald
    Tschandl, Philipp
    JAMA DERMATOLOGY, 2019, 155 (11) : 1291 - 1299
  • [23] Computer-aided detection in breast MRI: a systematic review and meta-analysis
    Monique D. Dorrius
    Marijke C. Jansen-van der Weide
    Peter M. A. van Ooijen
    Ruud M. Pijnappel
    Matthijs Oudkerk
    European Radiology, 2011, 21 : 1600 - 1608
  • [24] Computer-aided detection in breast MRI: a systematic review and meta-analysis
    Dorrius, Monique D.
    Jansen-van der Weide, Marijke C.
    van Ooijen, Peter M. A.
    Pijnappel, Ruud M.
    Oudkerk, Matthijs
    EUROPEAN RADIOLOGY, 2011, 21 (08) : 1600 - 1608
  • [25] ACCURACY OF REMOVABLE PARTIAL DENTURE METAL FRAMEWORKS FABRICATED BY COMPUTER-AIDED DESIGN/COMPUTER-AIDED MANUFACTURING METHOD: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Mai, Hai Yen
    Mai, Hang-Nga
    Kim, Ho-Jin
    Lee, Jaesik
    Lee, Du-Hyeong
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2022, 22 (03)
  • [26] Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies
    Bover-Ramos, Fernando
    Vina-Almunia, Jose
    Cervera-Ballester, Juan
    Penarrocha-Diago, Miguel
    Garcia-Mira, Berta
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 101 - 115
  • [27] Effect of Computer-Aided Navigation Techniques on the Accuracy of Endodontic Access Cavities: A Systematic Review and Meta-Analysis
    Zubizarreta-Macho, Alvaro
    Valle Castano, Sara
    Montiel-Company, Jose Maria
    Mena-Alvarez, Jesus
    BIOLOGY-BASEL, 2021, 10 (03):
  • [28] Accuracy assessment of robot-assisted implant surgery in dentistry: A systematic review and meta-analysis
    Yang, Jun
    Li, Hainan
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04):
  • [29] Accuracy of Computer-aided Diagnosis in Colonoscopy Varies According to Polyp Location: A Systematic Review and Meta-analysis
    Rizkala, Tommy
    Hassan, Cesare
    Mori, Yuichi
    Spadaccini, Marco
    Antonelli, Giulio
    Dekker, Evelien
    Houwen, Britt B. S. L.
    Pech, Oliver
    Baumer, Sebastian
    Rondonotti, Emanuele
    Radaelli, Franco
    Li, James Weiquan
    von Renteln, Daniel
    Misawa, Masashi
    Facciorusso, Antonio
    Maselli, Roberta
    Carrara, Silvia
    Fugazza, Alessandro
    Capogreco, Antonio
    Khalaf, Kareem
    Patel, Harsh
    Sharma, Prateek
    Rex, Douglas
    Repici, Alessandro
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2025, 23 (04) : 531 - 541
  • [30] Systematic review and meta-analysis of the accuracy of computer-aided diagnosis in identifying endoscopic remission in Ulcerative Colitis
    Gautham, A.
    Kader, R.
    JOURNAL OF CROHNS & COLITIS, 2024, 18 : I970 - I970