The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis

被引:17
|
作者
Fan, Shengchi [1 ,2 ]
Saenz-Ravello, Gustavo [3 ]
Diaz, Leonardo [4 ]
Wu, Yiqun [2 ]
Davo, Ruben [5 ]
Wang, Feng [2 ]
Magic, Marko [6 ]
Al-Nawas, Bilal [1 ]
Kaemmerer, Peer W. [1 ]
机构
[1] Univ Med Ctr Mainz, Dept Oral & Maxillofacial Surg, Plast Operat, D-55131 Mainz, Germany
[2] Shanghai Jiao Tong Univ, Peoples Hosp 9, Shanghai Res Inst Stomatol, Coll Stomatol,Dent Clin 2,Sch Med,Shanghai Key Lab, Shanghai 200011, Peoples R China
[3] Univ Chile, Fac Dent, Ctr Epidemiol & Surveillance Oral Dis CESOD, Santiago 8380420, Chile
[4] Univ Chile, Fac Dent, Postgrad Sch, Santiago 8380420, Chile
[5] Vithas Davo Inst Dent, Dept Implantol & Maxillofacial Surg, Alicante 03016, Spain
[6] Univ Belgrade, Sch Dent Med, Belgrade 11000, Serbia
关键词
zygomatic implant; edentulous; computer-aided surgery; navigation; guided surgery; SURGICAL NAVIGATION; GUIDED SURGERY; REHABILITATION; MANAGEMENT; MAXILLA; ERROR;
D O I
10.3390/jcm12165418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla. Methods: Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS. Results: A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34-2.29) at the entry point and 2.95 mm (95% CI: 1.66-4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04-4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83-1.54) at the entry point and 1.80 mm (95% CI: 1.10-2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43-2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69-2.39) at the entry point and 3.23 mm (95% CI: 2.34-4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86-5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups (p < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements. Conclusion: Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches.
引用
收藏
页数:22
相关论文
共 50 条
  • [11] Comparison of accuracy in freehand versus computer-assisted (dynamic and static) dental implant placement: A systematic review and meta-analysis
    Banerjee, Saurav
    Debnath, Anasua
    Paul, Priyanjali
    Banerjee, Tridib Nath
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01): : 22 - 29
  • [12] Accuracy of robotic surgery for dental implant placement: A systematic review and meta-analysis
    Wu, Xin-Yu
    Shi, Jun-Yu
    Qiao, Shi-Chong
    Tonetti, Maurizio S.
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) : 598 - 608
  • [13] Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis
    Wei, Shi-Min
    Zhu, Yu
    Wei, Jian-Xu
    Zhang, Chu-Nan
    Shi, Jun-Yu
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) : 383 - 393
  • [14] ACCURACY OF COMPUTER-AIDED IMPLANT SURGERY
    Cretu, Cosmin
    Agop-Forna, Doriana
    Bardi, Dimitris
    Cristea, Ioana
    Dascalu, Cristina
    Petruta, Siminiuc
    Forna, Norina
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2023, 15 (02): : 406 - 415
  • [15] Accuracy of robotic computer-assisted implant surgery in clinical studies: a systematic review and meta-analysis
    Zixin Luo
    An Li
    Alexey Unkovskiy
    Jiang Li
    Florian Beuer
    Zhe Wu
    Ping Li
    BMC Oral Health, 25 (1)
  • [16] Accuracy of computer-aided static and dynamic navigation systems in the placement of zygomatic dental implants
    Juan Ramón González Rueda
    Agustín Galparsoro Catalán
    Víctor Manuel de Paz Hermoso
    Elena Riad Deglow
    Álvaro Zubizarreta-Macho
    Jesús Pato Mourelo
    Javier Montero Martín
    Sofía Hernández Montero
    BMC Oral Health, 23
  • [17] Accuracy of computer-aided static and dynamic navigation systems in the placement of zygomatic dental implants
    Gonzalez Rueda, Juan Ramon
    Galparsoro Catalan, Agustin
    de Paz Hermoso, Victor Manuel
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Pato Mourelo, Jesus
    Montero Martin, Javier
    Hernandez Montero, Sofia
    BMC ORAL HEALTH, 2023, 23 (01)
  • [18] Accuracy of a Computer-Aided Dynamic Navigation System in the Placement of Zygomatic Dental Implants: An In Vitro Study
    Gonzalez Rueda, Juan Ramon
    Garcia Avila, Irene
    de Paz Hermoso, Victor Manuel
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Pato Mourelo, Jesus
    Montero Martin, Javier
    Hernandez Montero, Sofia
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [19] Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study
    Mediavilla Guzman, Alfonso
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Agustin-Panadero, Ruben
    Hernandez Montero, Sofia
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (12)
  • [20] Patient-centred outcomes and dental implant placement in computer-aided free flap mandibular reconstruction: a systematic review and meta-analysis
    Salinero, Lauren
    Boczar, Daniel
    Barrow, Brooke
    Berman, Zoe P.
    Diep, Gustave K.
    Trilles, Jorge
    Howard, Rachel
    Chaya, Bachar F.
    Colon, Ricardo Rodriguez
    Rodriguez, Eduardo D.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2022, 60 (10): : 1283 - 1291