A Comprehensive Analysis on the Influence of the Adopted Cumulative Peak Current Distribution in the Assessment of Overhead Lines Lightning Performance

被引:1
|
作者
Conceicao, Daiane [1 ,2 ]
Alipio, Rafael [2 ,3 ]
Lopes, Ivan J. S. [1 ]
Chisholm, William [4 ]
机构
[1] Univ Fed Minas Gerais, Grad Program Elect Engn, Ave Antonio Carlos 6627, BR-31270901 Belo Horizonte, MG, Brazil
[2] CEFET MG Fed Ctr Technol Educ Minas Gerais, Dept Elect Engn, Ave Amazonas,7675 Nova Gameleira, BR-30510000 Belo Horizonte, MG, Brazil
[3] Swiss Fed Inst Technol Lausanne EPFL, Electromagnet Compatibil Lab, CH-1015 Lausanne, Switzerland
[4] Associate METSCO EDM Kinectr, Toronto, ON, Canada
关键词
lightning; backflashover; outage rate; tower footing resistance; cumulative peak-current; attractive distance; LEADER PROGRESSION MODEL; ANALYTICAL REPRESENTATION; ELECTROGEOMETRIC MODEL; TRANSMISSION-LINES; STROKE SIMULATION; SURGE ARRESTERS; EXPOSURE; IMPEDANCE; NETWORKS;
D O I
10.3390/en16155836
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Backflashover rate (BFR) is strongly dependent on the cumulative peak current distribution (CCD) adopted in the calculations. An original aspect of the present work is that such dependence is simultaneously assessed in estimating the probability of the critical current being exceeded as well as in the annual number of flashes to the line. An IEEE brochure recommends that the distribution values that characterize the atmospheric characteristic of the region under study as accurately as possible be used. The objective of this article is to evaluate the impact of the use of different CCDs, related to several measurements carried out around the world, in the estimation of the lightning performance of transmission lines (TLs). Structures of 138, 230 and 500 kV were analyzed. In the simulations, representative curves of lightning associated with measurements taken at Monte San Salvatore (MSS), Morro do Cachimbo (MCS) and TLs in Japan (TLJ) were considered. The distributions recommended by the IEEE and by the CIGRE and the distributions of Berger obtained from MSS, MCS and TLJ were considered. The presented results indicate differences of up to 100% between the considered work distributions and the IEEE one for certain values of tower footing impedance.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Performance against Direct Lightning on 10kV Overhead Distribution Lines with Counterpoise Wires
    Cao, Jinxin
    Du, Yaping
    Ding, Yuxuan
    Qi, Ruihan
    Li, Zhe
    2021 35th International Conference on Lightning Protection, ICLP 2021 and 16th International Symposium on Lightning Protection, SIPDA 2021, 2021,
  • [42] Performance against Direct Lightning on 10kV Overhead Distribution Lines with Counterpoise Wires
    Cao, Jinxin
    Du, Yaping
    Ding, Yuxuan
    Qi, Ruihan
    Li, Zhe
    2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,
  • [43] Numeral Analysis on Lightning Shielding Performance of Overhead Lines based on Leader Progression Model
    Hu, Jing
    Wen, Xishan
    Lan, Lei
    Sun, Jiantao
    Wang, Yu
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3531 - 3534
  • [44] Indirect-lightning performance of distribution lines: Influence of protection devices
    Borghetti, A.
    Nucci, C. A.
    Paolone, M.
    Rachidi, F.
    2005/2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2006, : 455 - +
  • [45] Influence of surge arresters on the statistical evaluation of lightning performance of distribution lines
    Borghetti, A
    Nucci, CA
    Paolone, A
    Bernardi, M
    Malgarotti, S
    Mastandrea, I
    2004 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, 2004, : 776 - 781
  • [46] Waveform Analysis on Characteristics of Lightning Induced Overvoltages on 10kV Overhead Distribution Lines
    Yang Q.
    Zhang X.
    Sun J.
    Xu W.
    He W.
    Wang K.
    Qin Z.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (24): : 8900 - 8909
  • [47] Utilization of Underbuilt Shield Wires to Improve the Lightning Performance of Overhead Distribution Lines Hit by Direct Strokes
    Araneo, Rodolfo
    Andreotti, Amedeo
    Brandao Faria, Jose
    Celozzi, Salvatore
    Assante, Dario
    Verolino, Luigi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (04) : 1656 - 1666
  • [48] Evaluation of the backflashover performance of 150 kV and 400 kV double-circuit overhead transmission lines as affected by lightning attachment models and peak current distributions
    Datsios, Zacharias G.
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 235
  • [49] LIGHTNING PERFORMANCE OF OVERHEAD DISTRIBUTION NETWORK ASSESSMENT USING FUZZY GROUND FLASH DENSITY CONCEPT
    Soto, Edison
    Del Rio, Diego
    Perez, Ernesto
    Younes, Camilo
    2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 34 - 39
  • [50] LIGHTNING PERFORMANCE OF OVERHEAD DISTRIBUTION NETWORK ASSESSMENT USING FUZZY GROUND FLASH DENSITY CONCEPT
    Soto, Edison
    Del Rio, Diego
    Perez, Ernesto
    Younes, Camilo
    2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 138 - 143