A Comprehensive Analysis on the Influence of the Adopted Cumulative Peak Current Distribution in the Assessment of Overhead Lines Lightning Performance

被引:1
|
作者
Conceicao, Daiane [1 ,2 ]
Alipio, Rafael [2 ,3 ]
Lopes, Ivan J. S. [1 ]
Chisholm, William [4 ]
机构
[1] Univ Fed Minas Gerais, Grad Program Elect Engn, Ave Antonio Carlos 6627, BR-31270901 Belo Horizonte, MG, Brazil
[2] CEFET MG Fed Ctr Technol Educ Minas Gerais, Dept Elect Engn, Ave Amazonas,7675 Nova Gameleira, BR-30510000 Belo Horizonte, MG, Brazil
[3] Swiss Fed Inst Technol Lausanne EPFL, Electromagnet Compatibil Lab, CH-1015 Lausanne, Switzerland
[4] Associate METSCO EDM Kinectr, Toronto, ON, Canada
关键词
lightning; backflashover; outage rate; tower footing resistance; cumulative peak-current; attractive distance; LEADER PROGRESSION MODEL; ANALYTICAL REPRESENTATION; ELECTROGEOMETRIC MODEL; TRANSMISSION-LINES; STROKE SIMULATION; SURGE ARRESTERS; EXPOSURE; IMPEDANCE; NETWORKS;
D O I
10.3390/en16155836
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Backflashover rate (BFR) is strongly dependent on the cumulative peak current distribution (CCD) adopted in the calculations. An original aspect of the present work is that such dependence is simultaneously assessed in estimating the probability of the critical current being exceeded as well as in the annual number of flashes to the line. An IEEE brochure recommends that the distribution values that characterize the atmospheric characteristic of the region under study as accurately as possible be used. The objective of this article is to evaluate the impact of the use of different CCDs, related to several measurements carried out around the world, in the estimation of the lightning performance of transmission lines (TLs). Structures of 138, 230 and 500 kV were analyzed. In the simulations, representative curves of lightning associated with measurements taken at Monte San Salvatore (MSS), Morro do Cachimbo (MCS) and TLs in Japan (TLJ) were considered. The distributions recommended by the IEEE and by the CIGRE and the distributions of Berger obtained from MSS, MCS and TLJ were considered. The presented results indicate differences of up to 100% between the considered work distributions and the IEEE one for certain values of tower footing impedance.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Influence of a lossy ground on the lightning performance of overhead transmission lines
    Alipio, Rafael
    De Conti, Alberto
    Duarte, Naiara
    Rachidi, Farhad
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 214
  • [22] Characteristics of lightning induced voltage on overhead distribution lines and performance analysis of analytical algorithm
    Yu J.-L.
    Zhang Y.-D.
    Cheng L.
    Lu Z.-W.
    Kongzhi Lilun Yu Yingyong/Control Theory and Applications, 2022, 39 (05): : 941 - 949
  • [23] Analysis of the Cumulative Probability Distribution of the Stroke Angle in Lightning Incidence to Three-Phase Overhead Transmission Lines
    Lobato, Andre T.
    Schroeder, Marco A. O.
    Cruz, Douglas E.
    Reis, Maicon R.
    Moura, Rodolfo A. R.
    Sales, Warlley S.
    Nascimento, Luiz C.
    Assis, Sandro C.
    2013 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XII SIPDA), 2013, : 128 - 133
  • [24] Evaluation of Lightning Attachment and Coupling Models for the Estimation of the Lightning Performance of Overhead Distribution Lines
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    Pori, Aikaterini S.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1212 - 1216
  • [25] Influence of corona on the voltages induced by nearby lightning on overhead distribution lines
    Nucci, CA
    Guerrieri, S
    de Barros, MTC
    Rachidi, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (04) : 1265 - 1273
  • [26] Influence of corona on the voltages induced by nearby lightning on overhead distribution lines
    Nucci, CA
    Guerrieri, S
    de Barros, MTC
    Rachidi, F
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 2891 - 2891
  • [27] Indirect lightning performance of 10-kV overhead distribution lines
    Yu, Jianli
    Gu, Shanmao
    Liu, Jianjun
    Liu, He
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [28] Lightning performance analysis of overhead transmission lines using the EMTP
    Martinez, JA
    Castro-Aranda, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 2200 - 2210
  • [29] Lightning Performance Analysis of Overhead Subtransmission Lines in Power System
    Phayomhom, A.
    Kulwongwit, W.
    Rugthaicharoencheep, N.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 2024 - 2027
  • [30] Influence of a shield wire flashover on the indirect lightning performance assessment of distribution lines
    Yamanaka, Akifumi
    Ishimoto, Kazuyuki
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223